American HPA10240H045DV 2** Water Heater Specifications (3.6 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, American HPA10240H045DV 2** (Electric) achieves a certified 3.6 UEF rating across its 36-gallon nominal tank, 55 gal First Hour Rating (rank #401 of 706, PD 3417479) and verifies as Pass: +1.30 / +56.5% for 2029 DOE floors. Rated annual electricity draw of 902 kWh/yr equates to roughly $164/yr ($1,638 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith CAHP-40 2** (3.6 UEF).
- Uniform Energy Factor
- 3.6 UEF
- Cohort UEF Rank
- #401 of 706
- First Hour Rating
- 55 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.30 / +56.5%

American HPA10240H045DV 2** records 3.6 UEF efficiency, putting it #401 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: American HPA10240H045DV 2** exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.30 UEF (+56.5%). At EIA August 2026 national rates (18.16 cents/kWh), 902 kWh/yr for American HPA10240H045DV 2** runs ~$164/yr vs. ~$641/yr for a 0.92 UEF electric tank.
State electric sensitivity for American HPA10240H045DV 2**: 10-year operating spend spans $1,320 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,256 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside American HPA10240H045DV 2** (3.6 UEF) are A. O. Smith CAHP-40 2** (3.6 UEF, at parity) and Lochinvar CHPA-40 2** (3.6 UEF, at parity).
How Do American HPA10240H045DV 2** Specs Compare to Hybrid/Electric Heat Pump Medians?
American HPA10240H045DV 2** places #401 of 706 across 706 certified Hybrid/Electric Heat Pump configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | American | 79 certified listings | ENERGY STAR PD 3417479 |
| Model Number | HPA10240H045DV 2** | Draw pattern: Medium-Usage | HPA10240H045DV 2** |
| Uniform Energy Factor (UEF) | 3.6 | -0.10 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 55 gal | -17 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 902 kWh/yr | -170 kWh/yr vs. 1,072 kWh/yr median | Est. $164/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 426% | -3.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 66" H x 20" D | Verify 72 in. vertical headroom; clears 28 in. utility doorway (20" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 22 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States |
What Does HPA10240H045DV 2** Cost to Operate Across State Electricity Rates?
At 902 kWh/yr, American HPA10240H045DV 2** runs roughly $164/yr on the EIA national average tier under August 2026 Table 5.6.A rates.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $164/yr | $1,638 | $4,772 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $426/yr | $4,256 | $12,399 |
| California | 29.75 ¢/kWh ($0.2975) | $268/yr | $2,683 | $7,818 |
| Texas | 15.91 ¢/kWh ($0.1591) | $144/yr | $1,435 | $4,181 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $132/yr | $1,320 | $3,845 |
Are There Active CPSC Safety Recalls for American Water Heaters?
Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with American; match your serial plate before repair. See Serial Number Lookup.
- Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
- Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)
Which Certified Water Heaters Match HPA10240H045DV 2** Most Closely?
These 5 competing Hybrid/Electric Heat Pump units sit nearest to American HPA10240H045DV 2** by storage capacity and 3.6 UEF rating.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |
| Lochinvar CHPA-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |
| RELIANCE WATER HEATERS 10-40-DHPTA 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |
| State CSHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |
| A. O. Smith HPA10-40H45DV 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (at parity) | 902 |
Who Is American HPA10240H045DV 2** Best For — and When Should You Pick A. O. Smith CAHP-40 2**?
Evaluate whether American HPA10240H045DV 2**'s Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- American HPA10240H045DV 2** needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting American HPA10240H045DV 2** directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
What Are the Key Questions About American HPA10240H045DV 2**?
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does American HPA10240H045DV 2** (3.6 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, American HPA10240H045DV 2** records 3.6 UEF (Pass: +1.30 / +56.5%), placing #401 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.
Does American HPA10240H045DV 2** fit inside a tight hallway closet or low-headroom utility room?
American HPA10240H045DV 2** requires room for its 66 in. vertical shell and 20 in. diameter (verify 72 in. vertical headroom; clears 28 in. utility doorway (20" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern American HPA10240H045DV 2**?
For American HPA10240H045DV 2**, plan a 240V circuit at 22A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for American HPA10240H045DV 2**?
Using 902 kWh/yr, American HPA10240H045DV 2** generates an estimated $164/yr electric bill at 18.16 cents/kWh (ranging from $132/yr in Washington hydro tiers up to $426/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of American HPA10240H045DV 2** (3.6 UEF)?
American HPA10240H045DV 2** requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or A. O. Smith CAHP-40 2**.
What hot-water delivery rating governs American HPA10240H045DV 2**?
Rated for 55 gal FHR (-17 gal vs. 72 gal median), American HPA10240H045DV 2** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen American HPA10240H045DV 2** for recalls and tank age?
CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What alternative models sit closest to American HPA10240H045DV 2** in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is A. O. Smith CAHP-40 2** (3.6 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)