Skip to main content
ENERGY STAR water heater model · PD 2408760

American PCG62-50S65L 1** Water Heater Specifications (0.9 UEF)

The American PCG62-50S65L 1** (Gas Storage, Natural Gas) achieves a certified 0.9 UEF rating across its 49-gallon nominal tank, 118 gal First Hour Rating, ranking #1 of 71 among 71 ENERGY STAR Gas Storage models (PD 2408760). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.32 / +55.2%. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is A. O. Smith GC6-PS5065*V 1** (0.9 UEF).

Uniform Energy Factor
0.9 UEF
Cohort UEF Rank
#1 of 71
First Hour Rating
118 gal
Storage Volume
49 gal
Fuel / Type
Natural Gas / Gas Storage
DOE 2029 Rule Status
Pass: +0.32 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas Storage UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas Storage, marking American PCG62-50S65L 1** at 0.9 UEF.119510.86 UEF0.90 UEFMedian 0.902029 min 0.58American PCG62-50S65L 1**: 0.90
Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows American PCG62-50S65L 1** relative to the cohort median.
Efficiency comparison & rule summary

American PCG62-50S65L 1** (0.9 UEF) ranks #1 of 71 Gas Storage models — 51-way tie; more efficient than 28.2% of Gas Storage models, at the 0.90 UEF median.

American pcg62-50s65l 1** stores 49 gal nominal; 118 gal first hour rating (+23 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).

Peer comparison: American PCG62-50S65L 1** (0.9 UEF) compares closely with A. O. Smith GC6-PS5065*V 1** (0.9 UEF, at parity) and Envirosense Enercare ENV-50N-ENER 1** (0.9 UEF, at parity).

How Do American PCG62-50S65L 1** Specs Compare to Gas Storage Medians?

American PCG62-50S65L 1** places #1 of 71 across 71 certified Gas Storage configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandAmerican79 certified listingsENERGY STAR PD 2408760
Model NumberPCG62-50S65L 1**Draw pattern: High-UsagePCG62-50S65L 1**
Uniform Energy Factor (UEF)0.9At 0.90 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)118 gal+23 gal vs. 95 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency92%-2.0 pts vs. 94.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)54.5" H x 22" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D)Doorway & ceiling check
Electrical Circuit Requirements2 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for American Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 2 brand-level recall notices associated with American; match your serial plate before repair. See Serial Number Lookup.

2 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16171 (2016-05-24): Water Heating Technologies Recalls Gas Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Certified Water Heaters Match PCG62-50S65L 1** Most Closely?

These 5 competing Gas Storage units sit nearest to American PCG62-50S65L 1** by storage capacity and 0.9 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith GC6-PS5065*V 1** Gas Storage 49 gal 118 gal 0.9 (at parity) —
Envirosense Enercare ENV-50N-ENER 1** Gas Storage 49 gal 118 gal 0.9 (at parity) —
Envirosense Reliance Home Comfort ENV-50N-RHC 1** Gas Storage 49 gal 118 gal 0.9 (at parity) —
Envirosense ENV-50N 1** Gas Storage 49 gal 118 gal 0.9 (at parity) —
A. O. Smith GC9-PS5065NV 1** Gas Storage 49 gal 118 gal 0.9 (at parity) —

When Should Homeowners Skip American PCG62-50S65L 1** (Gas Storage)?

Check American PCG62-50S65L 1**'s mechanical constraints—including utility space, Natural Gas capacity, and Pass: +0.32 / +55.2% status—against typical residential installations.

Key Limitations & Exclusions

  • American PCG62-50S65L 1** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect American PCG62-50S65L 1**'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 118 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for American PCG62-50S65L 1** Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like A. O. Smith GC6-PS5065*V 1**.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

What Are the Key Questions About American PCG62-50S65L 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will American PCG62-50S65L 1** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.9 UEF, American PCG62-50S65L 1** shows Pass: +0.32 / +55.2% relative to May 6, 2029 federal DOE limits while placing #1 of 71 among 71 Gas Storage peers like A. O. Smith GC6-PS5065*V 1**.

Will American PCG62-50S65L 1** fit through a standard utility door and 72-inch basement ceiling?

Measuring 54.5 in. tall by 22 in. diameter, American PCG62-50S65L 1** notes: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support American PCG62-50S65L 1** during replacement?

Fueled by Natural Gas, American PCG62-50S65L 1** specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

What is the estimated 10-year operating spend for American PCG62-50S65L 1**?

Because American PCG62-50S65L 1** burns Natural Gas at 0.9 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 71 peers.

When is American PCG62-50S65L 1** a poor fit for a residential replacement?

Avoid American PCG62-50S65L 1** if household peak demand surpasses 118 gal per hour or if state DOE HEAR incentives require >=2.30 UEF heat-pump equipment.

What First Hour Rating or flow capacity does American PCG62-50S65L 1** deliver?

With 118 gal FHR (+23 gal vs. 95 gal median), American PCG62-50S65L 1** fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on American PCG62-50S65L 1**?

CPSC SaferProducts records show 2 brand-level recall notices mentioning American as of 2026-11-23, including #16171 (2016-05-24). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Does American PCG62-50S65L 1** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for American PCG62-50S65L 1**. Closest peer in Gas Storage is A. O. Smith GC6-PS5065*V 1** (0.9 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks