Ariston ARIHPWH-65-T Water Heater Specifications (4.05 UEF)
With PD 4437413 certification, Ariston ARIHPWH-65-T (Hybrid/Electric Heat Pump, Electric) achieves a certified 4.05 UEF rating across its 61-gallon nominal tank, 77 gal First Hour Rating, standing #61 of 706 across 706 peers with Pass: +1.55 / +62.0% for May 6, 2029. Rated annual electricity draw of 1,225 kWh/yr equates to roughly $222/yr ($2,225 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Lennox WHHP065T45MD240S**** (4.05 UEF).
- Uniform Energy Factor
- 4.05 UEF
- Cohort UEF Rank
- #61 of 706 (top 14.2%)
- First Hour Rating
- 77 gal
- Storage Volume
- 61 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.55 / +62.0%

ENERGY STAR certification places Ariston ARIHPWH-65-T at 4.05 UEF (#61 of 706; +0.35 UEF vs. 3.70 UEF median) in Hybrid/Electric Heat Pump.
May 6, 2029 readiness: Ariston ARIHPWH-65-T stands +1.55 UEF (+62.0%) relative to 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF). At EIA August 2026 national rates (18.16 cents/kWh), 1,225 kWh/yr for Ariston ARIHPWH-65-T runs ~$222/yr vs. ~$979/yr for a 0.92 UEF electric tank.
State electric sensitivity for Ariston ARIHPWH-65-T: 10-year operating spend spans $1,792 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $5,780 in Hawaii (Highest EIA State) (47.18 cents/kWh).
In the Hybrid/Electric Heat Pump tier, Lennox WHHP065T45MD240S**** (4.05 UEF, at parity) and Navien NWP500S065AUMB (4.03 UEF, delta -0.02) bracket Ariston ARIHPWH-65-T.
Where Does Ariston ARIHPWH-65-T Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, Ariston ARIHPWH-65-T holds #61 of 706 (top 14.2%); inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Ariston | 8 certified listings | ENERGY STAR PD 4437413 |
| Model Number | ARIHPWH-65-T | Draw pattern: High-Usage | ARIHPWH-65-T |
| Uniform Energy Factor (UEF) | 4.05 | +0.35 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 77 gal | +5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,225 kWh/yr | +153 kWh/yr vs. 1,072 kWh/yr median | Est. $222/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 446% | +17.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 50.5" H x 20.2" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-513A (GWP:630) | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Certification Date | 2025-12-12 | Certified 2025-12-12 | Markets: United States, Canada |
How Much Electricity Does ARIHPWH-65-T Use in Different States?
Estimated at $222/yr nationally (1,225 kWh/yr), 10-year utility spending for Ariston ARIHPWH-65-T shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $222/yr | $2,225 | $7,569 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $578/yr | $5,780 | $19,665 |
| California | 29.75 ¢/kWh ($0.2975) | $364/yr | $3,644 | $12,400 |
| Texas | 15.91 ¢/kWh ($0.1591) | $195/yr | $1,949 | $6,631 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $179/yr | $1,792 | $6,098 |
Does CPSC Flag Any Safety Notices on Ariston Units?
No open CPSC recall alerts appeared for Ariston as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to ARIHPWH-65-T?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to Ariston ARIHPWH-65-T's gallon capacity and 4.05 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Lennox WHHP065T45MD240S**** | Hybrid/Electric Heat Pump | 61 gal | 77 gal | 4.05 (at parity) | 1,225 |
| Navien NWP500S065AUMB | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.03 (-0.02) | 1,245 |
| Midea CAN3-RSJ-15/250RDVN3-L4 | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (-0.05) | 1,234 |
| Rinnai REHP65CW* | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (-0.05) | 1,234 |
| Midea MAHW-65VN3B | Hybrid/Electric Heat Pump | 61 gal | 80 gal | 4.0 (-0.05) | 1,234 |
Who Is Ariston ARIHPWH-65-T Best For — and When Should You Pick Lennox WHHP065T45MD240S****?
Evaluate whether Ariston ARIHPWH-65-T's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Ariston ARIHPWH-65-T needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Ariston ARIHPWH-65-T directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for Ariston ARIHPWH-65-T
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Ariston ARIHPWH-65-T (4.05 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Ariston ARIHPWH-65-T records 4.05 UEF (Pass: +1.55 / +62.0%), placing #61 of 706 (top 14.2%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Ariston ARIHPWH-65-T fit inside a tight hallway closet or low-headroom utility room?
Ariston ARIHPWH-65-T requires room for its 50.5 in. vertical shell and 20.2 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.2" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Ariston ARIHPWH-65-T?
For Ariston ARIHPWH-65-T, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Ariston ARIHPWH-65-T?
Using 1,225 kWh/yr, Ariston ARIHPWH-65-T generates an estimated $222/yr electric bill at 18.16 cents/kWh (ranging from $179/yr in Washington hydro tiers up to $578/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Ariston ARIHPWH-65-T (4.05 UEF)?
Ariston ARIHPWH-65-T requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Lennox WHHP065T45MD240S****.
What hot-water delivery rating governs Ariston ARIHPWH-65-T?
Rated for 77 gal FHR (+5 gal vs. 72 gal median), Ariston ARIHPWH-65-T prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Ariston ARIHPWH-65-T for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for Ariston; use our browser-only serial decoder to inspect Ariston ARIHPWH-65-T's age and warranty window.
What alternative models sit closest to Ariston ARIHPWH-65-T in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is Lennox WHHP065T45MD240S**** (4.05 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)