Bosch T9900 SE 160 Water Heater Specifications (0.95 UEF)
Certified at 0.95 UEF, Bosch T9900 SE 160 (Gas Tankless, Natural Gas, Propane) places #159 of 464 out of 464 ENERGY STAR models (PD 2453076). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.04 / +4.4%. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).
- Uniform Energy Factor
- 0.95 UEF
- Cohort UEF Rank
- #159 of 464
- First Hour Rating
- On-Demand
- Storage Volume
- Tankless
- Fuel / Type
- Natural Gas, Propane / Gas Tankless
- DOE 2029 Rule Status
- Pass: +0.04 / +4.4%

Tested at 0.95 UEF, Bosch T9900 SE 160 places #159 of 464 across 464 certified Gas Tankless configurations (At 0.95 UEF median).
Operating on Natural Gas, Propane, Bosch T9900 SE 160 beats the 2029 0.91 UEF floor by +0.04 UEF (+4.4%).
Closest alternatives to Bosch T9900 SE 160 include A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) alongside American GT-240-NEH 1** (0.95 UEF, at parity).
Which Specs Set Bosch T9900 SE 160 Apart From Cohort Averages?
Ranked #159 of 464 inside the 464-model Gas Tankless cohort, Bosch T9900 SE 160 is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Bosch | 12 certified listings | ENERGY STAR PD 2453076 |
| Model Number | T9900 SE 160 | Draw pattern: High-Usage | T9900 SE 160 |
| Uniform Energy Factor (UEF) | 0.95 | At 0.95 UEF median | 10 CFR 430 Test Method |
| Electrical Circuit Requirements | 2.7 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2023-04-07 | Certified 2023-04-07 | Markets: United States, Canada |
What Should Bosch Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC recall sweep recorded zero brand matches for Bosch; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.
How Do Five Nearby Gas Tankless Models Stack Up?
Five alternative Gas Tankless units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith ACT-199O-N 1** | Gas Tankless | — | — | 0.95 (at parity) | — |
| American GT-240-NEH 1** | Gas Tankless | — | — | 0.95 (at parity) | — |
| Bradford White RTG-K-160N1 | Gas Tankless | — | — | 0.95 (at parity) | — |
| Elios EROD150N0000 | Gas Tankless | — | — | 0.95 (at parity) | — |
| A. O. Smith ACT-199O-P 1*1 | Gas Tankless | — | — | 0.95 (at parity) | — |
When Should Homeowners Skip Bosch T9900 SE 160 (Gas Tankless)?
Check Bosch T9900 SE 160's mechanical constraints—including utility space, Natural Gas, Propane capacity, and Pass: +0.04 / +4.4% status—against typical residential installations.
Key Limitations & Exclusions
- Converting a 40K tank to Bosch T9900 SE 160 often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
- Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Bosch T9900 SE 160's heat exchanger.
- Condensing Bosch T9900 SE 160 requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Bosch T9900 SE 160
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Will Bosch T9900 SE 160 stay compliant after the May 6, 2029 DOE standard takes effect?
Tested at 0.95 UEF, Bosch T9900 SE 160 shows Pass: +0.04 / +4.4% relative to May 6, 2029 federal DOE limits while placing #159 of 464 among 464 Gas Tankless peers like A. O. Smith ACT-199O-N 1**.
Will Bosch T9900 SE 160 fit through a standard utility door and 72-inch basement ceiling?
Using a wall-mounted gas tankless chassis, Bosch T9900 SE 160 eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.
Do existing utility hookups support Bosch T9900 SE 160 during replacement?
Fueled by Natural Gas, Propane, Bosch T9900 SE 160 specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.
What is the estimated 10-year operating spend for Bosch T9900 SE 160?
Because Bosch T9900 SE 160 burns Natural Gas, Propane at 0.95 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 464 peers.
When is Bosch T9900 SE 160 a poor fit for a residential replacement?
Skip Bosch T9900 SE 160 as a quick swap when long 1/2 in. iron gas lines starve ignition (triggering E003/11 codes) or when Type B metal chimney vents cannot handle condensing PVC.
What First Hour Rating or flow capacity does Bosch T9900 SE 160 deliver?
As an on-demand Gas Tankless model, Bosch T9900 SE 160 has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.
How do you verify manufacturing age and recall status on Bosch T9900 SE 160?
Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Bosch; verify exact manufacturing week for Bosch T9900 SE 160 using the Serial Number Lookup tool.
Does Bosch T9900 SE 160 qualify for DOE HEAR incentives after 25C expired?
After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Bosch T9900 SE 160. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)