Skip to main content
ENERGY STAR water heater model · PD 2453076

Bosch T9900 SE 160 Water Heater Specifications (0.95 UEF)

Certified at 0.95 UEF, Bosch T9900 SE 160 (Gas Tankless, Natural Gas, Propane) places #159 of 464 out of 464 ENERGY STAR models (PD 2453076). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.04 / +4.4%. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas, Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Bosch T9900 SE 160 at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Bosch T9900 SE 160: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Bosch T9900 SE 160 relative to the cohort median.
Efficiency comparison & rule summary

Tested at 0.95 UEF, Bosch T9900 SE 160 places #159 of 464 across 464 certified Gas Tankless configurations (At 0.95 UEF median).

Operating on Natural Gas, Propane, Bosch T9900 SE 160 beats the 2029 0.91 UEF floor by +0.04 UEF (+4.4%).

Closest alternatives to Bosch T9900 SE 160 include A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) alongside American GT-240-NEH 1** (0.95 UEF, at parity).

Which Specs Set Bosch T9900 SE 160 Apart From Cohort Averages?

Ranked #159 of 464 inside the 464-model Gas Tankless cohort, Bosch T9900 SE 160 is evaluated row by row below against category medians.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandBosch12 certified listingsENERGY STAR PD 2453076
Model NumberT9900 SE 160Draw pattern: High-UsageT9900 SE 160
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Electrical Circuit Requirements2.7 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2023-04-07Certified 2023-04-07Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Bosch Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Bosch; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Gas Tankless Models Stack Up?

Five alternative Gas Tankless units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
Elios EROD150N0000 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

When Should Homeowners Skip Bosch T9900 SE 160 (Gas Tankless)?

Check Bosch T9900 SE 160's mechanical constraints—including utility space, Natural Gas, Propane capacity, and Pass: +0.04 / +4.4% status—against typical residential installations.

Key Limitations & Exclusions

  • Converting a 40K tank to Bosch T9900 SE 160 often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Bosch T9900 SE 160's heat exchanger.
  • Condensing Bosch T9900 SE 160 requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Bosch T9900 SE 160 delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Frequently Asked Technical Questions: Bosch T9900 SE 160

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Bosch T9900 SE 160 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.95 UEF, Bosch T9900 SE 160 shows Pass: +0.04 / +4.4% relative to May 6, 2029 federal DOE limits while placing #159 of 464 among 464 Gas Tankless peers like A. O. Smith ACT-199O-N 1**.

Will Bosch T9900 SE 160 fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted gas tankless chassis, Bosch T9900 SE 160 eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

Do existing utility hookups support Bosch T9900 SE 160 during replacement?

Fueled by Natural Gas, Propane, Bosch T9900 SE 160 specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

What is the estimated 10-year operating spend for Bosch T9900 SE 160?

Because Bosch T9900 SE 160 burns Natural Gas, Propane at 0.95 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 464 peers.

When is Bosch T9900 SE 160 a poor fit for a residential replacement?

Skip Bosch T9900 SE 160 as a quick swap when long 1/2 in. iron gas lines starve ignition (triggering E003/11 codes) or when Type B metal chimney vents cannot handle condensing PVC.

What First Hour Rating or flow capacity does Bosch T9900 SE 160 deliver?

As an on-demand Gas Tankless model, Bosch T9900 SE 160 has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.

How do you verify manufacturing age and recall status on Bosch T9900 SE 160?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Bosch; verify exact manufacturing week for Bosch T9900 SE 160 using the Serial Number Lookup tool.

Does Bosch T9900 SE 160 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Bosch T9900 SE 160. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)