Skip to main content
ENERGY STAR water heater model · PD 4528747

Elios EROD150P0000 Water Heater Specifications (0.95 UEF)

Engineered as a Propane Gas Tankless unit, Elios EROD150P0000 achieves a certified 0.95 UEF rating and ranks #159 of 464 in its 464-model cohort (PD 4528747), recording Pass: +0.04 / +4.4% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Elios EROD150P0000 at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Elios EROD150P0000: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Elios EROD150P0000 relative to the cohort median.
Efficiency comparison & rule summary

Within the 464-unit Gas Tankless cohort, Elios EROD150P0000 logs 0.95 UEF and ranks #159 of 464.

Elios EROD150P0000 delivers +0.04 UEF (+4.4%) margin above the 0.91 UEF Propane tankless mandate.

Cross-shopping Elios EROD150P0000 (0.95 UEF)? Check A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity).

What Physical and Thermal Ratings Define Elios EROD150P0000?

Positioning at #159 of 464 out of 464 Gas Tankless peers, Elios EROD150P0000 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandElios8 certified listingsENERGY STAR PD 4528747
Model NumberEROD150P0000Draw pattern: High-UsageEROD150P0000
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Electrical Circuit Requirements1.3 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2025-12-19Certified 2025-12-19Markets: Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Elios Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Elios; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Elios EROD150P0000?

Homeowners cross-shopping Elios EROD150P0000 frequently review these five Gas Tankless models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

When Should Homeowners Skip Elios EROD150P0000 (Gas Tankless)?

Check Elios EROD150P0000's mechanical constraints—including utility space, Propane capacity, and Pass: +0.04 / +4.4% status—against typical residential installations.

Key Limitations & Exclusions

  • Converting a 40K tank to Elios EROD150P0000 often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Elios EROD150P0000's heat exchanger.
  • Condensing Elios EROD150P0000 requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Elios EROD150P0000 delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Sizing, Efficiency & Recall Answers for Elios EROD150P0000

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Elios EROD150P0000 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.95 UEF, Elios EROD150P0000 shows Pass: +0.04 / +4.4% relative to May 6, 2029 federal DOE limits while placing #159 of 464 among 464 Gas Tankless peers like A. O. Smith ACT-199O-N 1**.

Will Elios EROD150P0000 fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted gas tankless chassis, Elios EROD150P0000 eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

Do existing utility hookups support Elios EROD150P0000 during replacement?

Fueled by Propane, Elios EROD150P0000 specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

What is the estimated 10-year operating spend for Elios EROD150P0000?

Because Elios EROD150P0000 burns Propane at 0.95 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 464 peers.

When is Elios EROD150P0000 a poor fit for a residential replacement?

Skip Elios EROD150P0000 as a quick swap when long 1/2 in. iron gas lines starve ignition (triggering E003/11 codes) or when Type B metal chimney vents cannot handle condensing PVC.

What First Hour Rating or flow capacity does Elios EROD150P0000 deliver?

As an on-demand Gas Tankless model, Elios EROD150P0000 has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.

How do you verify manufacturing age and recall status on Elios EROD150P0000?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Elios; verify exact manufacturing week for Elios EROD150P0000 using the Serial Number Lookup tool.

Does Elios EROD150P0000 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Elios EROD150P0000. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks