Skip to main content
ENERGY STAR water heater model · PD 4528741

Elios EROD199P0000 Water Heater Specifications (0.95 UEF)

Certified at 0.95 UEF, Elios EROD199P0000 (Gas Tankless, Propane) places #159 of 464 out of 464 ENERGY STAR models (PD 4528741). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.04 / +4.4%. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Elios EROD199P0000 at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Elios EROD199P0000: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Elios EROD199P0000 relative to the cohort median.
Efficiency comparison & rule summary

Tested at 0.95 UEF, Elios EROD199P0000 places #159 of 464 across 464 certified Gas Tankless configurations (At 0.95 UEF median).

Operating on Propane, Elios EROD199P0000 beats the 2029 0.91 UEF floor by +0.04 UEF (+4.4%).

Closest alternatives to Elios EROD199P0000 include A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) alongside American GT-240-NEH 1** (0.95 UEF, at parity).

What Physical and Thermal Ratings Define Elios EROD199P0000?

Positioning at #159 of 464 out of 464 Gas Tankless peers, Elios EROD199P0000 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandElios8 certified listingsENERGY STAR PD 4528741
Model NumberEROD199P0000Draw pattern: High-UsageEROD199P0000
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Electrical Circuit Requirements1.3 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-03-18Certified 2024-03-18Markets: Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Elios Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Elios; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Elios EROD199P0000?

Homeowners cross-shopping Elios EROD199P0000 frequently review these five Gas Tankless models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

What Are the Limitations of Elios EROD199P0000 and Who Should Not Install It?

Before ordering Elios EROD199P0000 (Gas Tankless, 0.95 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Converting a 40K tank to Elios EROD199P0000 often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Elios EROD199P0000's heat exchanger.
  • Condensing Elios EROD199P0000 requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Elios EROD199P0000 delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Sizing, Efficiency & Recall Answers for Elios EROD199P0000

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Elios EROD199P0000 pass the May 6, 2029 federal DOE efficiency rule?

Elios EROD199P0000 carries a verified 0.95 UEF rating (Pass: +0.04 / +4.4%), ranking #159 of 464 across 464 ENERGY STAR Gas Tankless models under 10 CFR 430.32.

What doorway width and ceiling height does Elios EROD199P0000 need?

Elios EROD199P0000 mounts as a gas tankless without a bulky floor tank (wall-hung / compact envelope). Verify vent termination distances and combustion air clearances per IPC or UPC.

What gas pipe size or electrical breaker does Elios EROD199P0000 require?

Elios EROD199P0000 runs on Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

How much electricity or energy does Elios EROD199P0000 cost per year to run?

ENERGY STAR rates Elios EROD199P0000 as a Propane heater (0.95 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas Tankless draw.

Who should NOT install Elios EROD199P0000, and what are its limits?

Elios EROD199P0000 (0.95 UEF) is rarely a drop-in swap over a 40K tank if existing 1/2 in. gas pipe cannot supply 199,000 BTU/h or hardness exceeds 7.0 GPG without descaling.

How many bathrooms or people can Elios EROD199P0000 serve at peak demand?

Elios EROD199P0000 provides continuous Gas Tankless delivery rather than a fixed storage FHR; size GPM flow against winter incoming groundwater temperature and 2.0 GPM showers.

Are there CPSC safety recalls or serial checks for Elios EROD199P0000?

No active CPSC recalls matched Elios as of 2026-11-23. Always decode the serial tag on Elios EROD199P0000 because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Elios EROD199P0000, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks