Envirosense ENV-40N 1** Water Heater Specifications (0.9 UEF)
Engineered as a Natural Gas Gas Storage unit, Envirosense ENV-40N 1** achieves a certified 0.9 UEF rating across its 38-gallon nominal tank, 86 gal First Hour Rating and ranks #1 of 71 in its 71-model cohort (PD 2408757), recording Pass: +0.32 / +55.2% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is A. O. Smith GC6-PS4050*V 1** (0.9 UEF).
- Uniform Energy Factor
- 0.9 UEF
- Cohort UEF Rank
- #1 of 71
- First Hour Rating
- 86 gal
- Storage Volume
- 38 gal
- Fuel / Type
- Natural Gas / Gas Storage
- DOE 2029 Rule Status
- Pass: +0.32 / +55.2%

Within the 71-unit Gas Storage cohort, Envirosense ENV-40N 1** logs 0.9 UEF and ranks #1 of 71.
Envirosense env-40n 1** stores 38 gal nominal; 86 gal first hour rating (-9 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).
Cross-shopping Envirosense ENV-40N 1** (0.9 UEF)? Check A. O. Smith GC6-PS4050*V 1** (0.9 UEF, at parity) and American PCG62-40S50L 1** (0.9 UEF, at parity).
How Complete Are the Certified Metrics for Envirosense ENV-40N 1**?
Standing at #1 of 71 among 71 certified Gas Storage heaters, Envirosense ENV-40N 1** brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Envirosense | 4 certified listings | ENERGY STAR PD 2408757 |
| Model Number | ENV-40N 1** | Draw pattern: High-Usage | ENV-40N 1** |
| Uniform Energy Factor (UEF) | 0.9 | At 0.90 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 86 gal | -9 gal vs. 95 gal median | 10 CFR 430 Recovery Test |
| Thermal Recovery Efficiency | 91% | -3.0 pts vs. 94.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 44.7" H x 22" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 2 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2023-02-23 | Certified 2023-02-23 | Markets: United States, Canada |
Are Envirosense Models Affected by Current CPSC Notices?
Zero brand-level CPSC hazard notices matched Envirosense in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.
Which 5 Models Offer Similar Output to ENV-40N 1**?
Ordered by minimal capacity and UEF spread relative to Envirosense ENV-40N 1**, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith GC6-PS4050*V 1** | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| American PCG62-40S50L 1** | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| Envirosense Enercare ENV-40N-ENER 1** | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| Envirosense Reliance Home Comfort ENV-40N-RHC 1** | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
| A. O. Smith GC9-PS4050NV 1** | Gas Storage | 38 gal | 86 gal | 0.9 (at parity) | — |
What Installation Caveats Apply Before Buying Envirosense ENV-40N 1**?
Even high-UEF units like Envirosense ENV-40N 1** (0.9 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.
Key Limitations & Exclusions
- Envirosense ENV-40N 1** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
- Drain tank sediment yearly and inspect Envirosense ENV-40N 1**'s sacrificial anode rod every 4–6 years.
- Peak simultaneous draws exceeding 86 gal will deplete stored recovery capacity.
Which Option Fits Your Situation?
Practical Specs & Code Questions for Envirosense ENV-40N 1**
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is Envirosense ENV-40N 1** eligible for continued manufacture past May 6, 2029?
At 0.9 UEF, Envirosense ENV-40N 1** achieves Pass: +0.32 / +55.2% for the 2029 DOE standard and stands #1 of 71 against A. O. Smith GC6-PS4050*V 1** and American PCG62-40S50L 1**.
How tall and wide is Envirosense ENV-40N 1**, and what service clearance is needed?
Physical dimensions for Envirosense ENV-40N 1** are 44.7 in. height and 22 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d)); verify stair turns and drain pan width before delivery.
Will Envirosense ENV-40N 1** require upgrading household electrical panels or gas piping?
Check Natural Gas piping and venting for Envirosense ENV-40N 1** (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.
Is Envirosense ENV-40N 1** economical to operate at 18.16 cents/kWh US electric rates?
Fuel bills for Envirosense ENV-40N 1** (Natural Gas, 0.9 UEF) hinge on household gallon demand and local gas utility tariffs compared with A. O. Smith GC6-PS4050*V 1**.
Which installation bottlenecks limit Envirosense ENV-40N 1**?
Check local 10 CFR 430.32(d)(2) phase-in timing (Pass: +0.32 / +55.2%) and physical doorway clearances before choosing Envirosense ENV-40N 1** over A. O. Smith GC6-PS4050*V 1**.
How does Envirosense ENV-40N 1** handle simultaneous showers and laundry?
Delivering 86 gal in the first hour (-9 gal vs. 95 gal median), Envirosense ENV-40N 1** combines 38 gal tank storage with rapid burner/element recovery.
How long is the warranty on Envirosense ENV-40N 1** and how do you decode its serial?
CPSC records show 0 active plumbing recalls for Envirosense as of 2026-11-23. Confirm install proof and serial manufacture year on Envirosense ENV-40N 1** before calling service.
How do 2026 post-OBBBA rebates affect buying Envirosense ENV-40N 1**?
Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas Storage is A. O. Smith GC6-PS4050*V 1** (0.9 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)