Friedrich PROH40 T2 FD400-30 Water Heater Specifications (3.83 UEF)
In the 706-unit Hybrid/Electric Heat Pump class, Friedrich PROH40 T2 FD400-30 (Electric) achieves a certified 3.83 UEF rating across its 36-gallon nominal tank, 60 gal First Hour Rating (rank #230 of 706, PD 3554259) and verifies as Pass: +1.53 / +66.5% for 2029 DOE floors. Rated annual electricity draw of 859 kWh/yr equates to roughly $156/yr ($1,560 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Rheem CPROPH40 T2 RH400-30 (3.83 UEF).
- Uniform Energy Factor
- 3.83 UEF
- Cohort UEF Rank
- #230 of 706 (top 37.8%)
- First Hour Rating
- 60 gal
- Storage Volume
- 36 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +1.53 / +66.5%

Friedrich PROH40 T2 FD400-30 records 3.83 UEF efficiency, putting it #230 of 706 among 706 Hybrid/Electric Heat Pump peers.
10 CFR 430.32(d)(2) compliance: Friedrich PROH40 T2 FD400-30 exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.53 UEF (+66.5%). At EIA August 2026 national rates (18.16 cents/kWh), 859 kWh/yr for Friedrich PROH40 T2 FD400-30 runs ~$156/yr vs. ~$649/yr for a 0.92 UEF electric tank.
State electric sensitivity for Friedrich PROH40 T2 FD400-30: 10-year operating spend spans $1,257 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,053 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Competing options beside Friedrich PROH40 T2 FD400-30 (3.83 UEF) are Rheem CPROPH40 T2 RH400-30 (3.83 UEF, at parity) and Richmond 10CE40-HP5U30 (3.83 UEF, at parity).
How Complete Are the Certified Metrics for Friedrich PROH40 T2 FD400-30?
Standing at #230 of 706 (top 37.8%) among 706 certified Hybrid/Electric Heat Pump heaters, Friedrich PROH40 T2 FD400-30 brings measurable deltas in recovery, footprint, and energy efficiency.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Friedrich | 61 certified listings | ENERGY STAR PD 3554259 |
| Model Number | PROH40 T2 FD400-30 | Draw pattern: Medium-Usage | PROH40 T2 FD400-30 |
| Uniform Energy Factor (UEF) | 3.83 | +0.13 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 60 gal | -12 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 859 kWh/yr | -213 kWh/yr vs. 1,072 kWh/yr median | Est. $156/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 434% | +5.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 62.3" H x 20.3" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 240 V / 21 A max | Requires 240V dedicated branch circuit; check panel capacity | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R-134a (GWP:1430) | Check regional AIM Act phase-down transition | EPA AIM Act Compliance |
| Certification Date | 2026-10-15 | Certified 2026-10-15 | Markets: United States |
What Is the Projected Utility Bill for PROH40 T2 FD400-30 by State?
At 859 kWh/yr, Friedrich PROH40 T2 FD400-30 averages about $156/yr across US households—see 10-year payback spreads versus 0.92 UEF resistance tanks.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $156/yr | $1,560 | $4,934 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $405/yr | $4,053 | $12,819 |
| California | 29.75 ¢/kWh ($0.2975) | $256/yr | $2,556 | $8,083 |
| Texas | 15.91 ¢/kWh ($0.1591) | $137/yr | $1,367 | $4,323 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $126/yr | $1,257 | $3,975 |
Are Friedrich Models Affected by Current CPSC Notices?
Zero brand-level CPSC hazard notices matched Friedrich in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.
Which 5 Models Offer Similar Output to PROH40 T2 FD400-30?
Ordered by minimal capacity and UEF spread relative to Friedrich PROH40 T2 FD400-30, these five certified peers give direct replacement benchmarks.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Rheem CPROPH40 T2 RH400-30 | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| Richmond 10CE40-HP5U30 | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| Ruud CPROPH40 T2 CD375-30 | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
| A. O. Smith CAHP-40 2** | Hybrid/Electric Heat Pump | 36 gal | 55 gal | 3.6 (-0.23) | 902 |
| Rheem CPROPH40 T2 RH400-SO | Hybrid/Electric Heat Pump | 36 gal | 60 gal | 3.83 (at parity) | 859 |
Who Is Friedrich PROH40 T2 FD400-30 Best For — and When Should You Pick Rheem CPROPH40 T2 RH400-30?
Evaluate whether Friedrich PROH40 T2 FD400-30's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- Friedrich PROH40 T2 FD400-30 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 49 dBA; avoid mounting Friedrich PROH40 T2 FD400-30 directly beside quiet bedrooms.
- Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Practical Specs & Code Questions for Friedrich PROH40 T2 FD400-30
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does Friedrich PROH40 T2 FD400-30 (3.83 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Friedrich PROH40 T2 FD400-30 records 3.83 UEF (Pass: +1.53 / +66.5%), placing #230 of 706 (top 37.8%) out of 706 certified Hybrid/Electric Heat Pump configurations.
Does Friedrich PROH40 T2 FD400-30 fit inside a tight hallway closet or low-headroom utility room?
Friedrich PROH40 T2 FD400-30 requires room for its 62.3 in. vertical shell and 20.3 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (20.3" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern Friedrich PROH40 T2 FD400-30?
For Friedrich PROH40 T2 FD400-30, plan a 240V circuit at 21A max (Requires 240V dedicated branch circuit; check panel capacity) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for Friedrich PROH40 T2 FD400-30?
Using 859 kWh/yr, Friedrich PROH40 T2 FD400-30 generates an estimated $156/yr electric bill at 18.16 cents/kWh (ranging from $126/yr in Washington hydro tiers up to $405/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of Friedrich PROH40 T2 FD400-30 (3.83 UEF)?
Friedrich PROH40 T2 FD400-30 requires >=450 cu ft air space, 240V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Rheem CPROPH40 T2 RH400-30.
What hot-water delivery rating governs Friedrich PROH40 T2 FD400-30?
Rated for 60 gal FHR (-12 gal vs. 72 gal median), Friedrich PROH40 T2 FD400-30 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen Friedrich PROH40 T2 FD400-30 for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for Friedrich; use our browser-only serial decoder to inspect Friedrich PROH40 T2 FD400-30's age and warranty window.
What alternative models sit closest to Friedrich PROH40 T2 FD400-30 in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is Rheem CPROPH40 T2 RH400-30 (3.83 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)