GE Profile PJ65S10FPY01 Water Heater Specifications (3.4 UEF)
Certified at 3.4 UEF across its 65-gallon nominal tank, 77 gal First Hour Rating, GE Profile PJ65S10FPY01 (Hybrid/Electric Heat Pump, Electric) places #629 of 706 out of 706 ENERGY STAR models (PD 4480871). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.90 / +36.0%. Rated annual electricity draw of 1,459 kWh/yr equates to roughly $265/yr ($2,650 over 10 years) at 18.16 cents/kWh. Closest certified alternative is Cala Systems, Inc RDH6524M1 (3.61 UEF).
- Uniform Energy Factor
- 3.4 UEF
- Cohort UEF Rank
- #629 of 706
- First Hour Rating
- 77 gal
- Storage Volume
- 65 gal
- Fuel / Type
- Electric / Hybrid/Electric Heat Pump
- DOE 2029 Rule Status
- Pass: +0.90 / +36.0%

Tested at 3.4 UEF, GE Profile PJ65S10FPY01 places #629 of 706 across 706 certified Hybrid/Electric Heat Pump configurations (-0.30 UEF vs. 3.70 UEF median).
GE Profile PJ65S10FPY01 clears 10 CFR 430.32(d)(2) Electric >55 to <=120 gal (2.50 UEF) by +0.90 UEF (+36.0% headroom). At EIA August 2026 national rates (18.16 cents/kWh), 1,459 kWh/yr for GE Profile PJ65S10FPY01 runs ~$265/yr vs. ~$979/yr for a 0.92 UEF electric tank. Acoustic output is 41 dBA (quieter than 81.2% of Hybrid/Electric Heat Pump models).
State electric sensitivity for GE Profile PJ65S10FPY01: 10-year operating spend spans $2,135 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $6,884 in Hawaii (Highest EIA State) (47.18 cents/kWh).
Closest alternatives to GE Profile PJ65S10FPY01 include Cala Systems, Inc RDH6524M1 (3.61 UEF, delta +0.21) alongside Bradford White RE2HP65**-1NCTT (4.2 UEF, delta +0.80).
Where Does GE Profile PJ65S10FPY01 Rank Against Peer Hybrid/Electric Heat Pump Units?
Audited against 706 ENERGY STAR Hybrid/Electric Heat Pump listings, GE Profile PJ65S10FPY01 holds #629 of 706; inspect footprint, circuit load, and efficiency deltas here.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | GE Profile | 18 certified listings | ENERGY STAR PD 4480871 |
| Model Number | PJ65S10FPY01 | Draw pattern: High-Usage | PJ65S10FPY01 |
| Uniform Energy Factor (UEF) | 3.4 | -0.30 UEF vs. 3.70 UEF median | 10 CFR 430 Test Method |
| First Hour Rating (FHR) | 77 gal | +5 gal vs. 72 gal median | 10 CFR 430 Recovery Test |
| Rated Annual Electricity Use | 1,459 kWh/yr | +387 kWh/yr vs. 1,072 kWh/yr median | Est. $265/yr @ $0.1816/kWh (EIA US Avg) |
| Thermal Recovery Efficiency | 388% | -41.0 pts vs. 429.0% median | ENERGY STAR Dataset |
| Physical Envelope (H x Dia) | 47.5" H x 21.5" D | Fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" D) | Doorway & ceiling check |
| Electrical Circuit Requirements | 120 V / 7.5 A max | 120V plug-in retrofit circuit; slower heat-pump-only recovery | NEC / Branch circuit check |
| Heat Pump Refrigerant & GWP | R1234YF | Lower-GWP refrigerant alignment (EPA AIM Act) | EPA AIM Act Compliance |
| Sound Pressure Level | 41 dBA | top 18.8% · quieter than 81.2% of Hybrid/Electric Heat Pump models · -8 dBA vs. 49 dBA median | Indoor placement check |
| Certification Date | 2025-07-30 | Certified 2025-07-30 | Markets: Canada |
How Much Electricity Does PJ65S10FPY01 Use in Different States?
Estimated at $265/yr nationally (1,459 kWh/yr), 10-year utility spending for GE Profile PJ65S10FPY01 shifts sharply between low-rate hydro and coastal grids.
| Jurisdiction (EIA Aug 2026) | Residential Rate | Annual Cost | 10-Yr Operating Spend | 10-Yr Savings vs. 0.92 UEF |
|---|---|---|---|---|
| United States Average | 18.16 ¢/kWh ($0.1816) | $265/yr | $2,650 | $7,142 |
| Hawaii (Highest EIA State) | 47.18 ¢/kWh ($0.4718) | $688/yr | $6,884 | $18,556 |
| California | 29.75 ¢/kWh ($0.2975) | $434/yr | $4,341 | $11,701 |
| Texas | 15.91 ¢/kWh ($0.1591) | $232/yr | $2,321 | $6,257 |
| Washington (Lowest Hydro Tier) | 14.63 ¢/kWh ($0.1463) | $213/yr | $2,135 | $5,754 |
Does CPSC Flag Any Safety Notices on GE Profile Units?
No open CPSC recall alerts appeared for GE Profile as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.
Which Competing Hybrid/Electric Heat Pump Models Compare Closest to PJ65S10FPY01?
Compare five nearby ENERGY STAR Hybrid/Electric Heat Pump options matched closely to GE Profile PJ65S10FPY01's gallon capacity and 3.4 UEF efficiency.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| Cala Systems, Inc RDH6524M1 | Hybrid/Electric Heat Pump | 65 gal | 79 gal | 3.61 (+0.21) | — |
| Bradford White RE2HP65**-1NCTT | Hybrid/Electric Heat Pump | 65 gal | 82 gal | 4.2 (+0.80) | 1,181 |
| JETGLAS RE2HP65*-1NCTT | Hybrid/Electric Heat Pump | 65 gal | 82 gal | 4.2 (+0.80) | 1,181 |
| Smart Solar SSG2-ES 65 | Hybrid/Electric Heat Pump | 65 gal | 46 gal | 2.52 (-0.88) | 893 |
| Bradford White RE2H65T**-***** | Hybrid/Electric Heat Pump | 64 gal | 79 gal | 3.64 (+0.24) | 1,363 |
Who Is GE Profile PJ65S10FPY01 Best For — and When Should You Pick Cala Systems, Inc RDH6524M1?
Evaluate whether GE Profile PJ65S10FPY01's Hybrid/Electric Heat Pump architecture matches your existing mechanical room and local utility tariffs before purchasing.
Key Limitations & Exclusions
- GE Profile PJ65S10FPY01 needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
- Compressor runs near 41 dBA; avoid mounting GE Profile PJ65S10FPY01 directly beside quiet bedrooms.
- Requires condensate drain routing and 120V electrical capacity; verify state DOE HEAR status.
Which Option Fits Your Situation?
Common Homeowner Questions for GE Profile PJ65S10FPY01
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
How does GE Profile PJ65S10FPY01 (3.4 UEF) compare to 2029 federal DOE floors?
Evaluated against May 6, 2029 10 CFR 430.32 thresholds, GE Profile PJ65S10FPY01 records 3.4 UEF (Pass: +0.90 / +36.0%), placing #629 of 706 out of 706 certified Hybrid/Electric Heat Pump configurations.
Does GE Profile PJ65S10FPY01 fit inside a tight hallway closet or low-headroom utility room?
GE Profile PJ65S10FPY01 requires room for its 47.5 in. vertical shell and 21.5 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (21.5" d)), plus service access for annual sediment draining.
What power supply or fuel line specs govern GE Profile PJ65S10FPY01?
For GE Profile PJ65S10FPY01, plan a 120V circuit at 7.5A max (120V plug-in retrofit circuit; slower heat-pump-only recovery) and keep a dedicated shutoff disconnect within sight of the unit.
What annual utility bill should homeowners budget for GE Profile PJ65S10FPY01?
Using 1,459 kWh/yr, GE Profile PJ65S10FPY01 generates an estimated $265/yr electric bill at 18.16 cents/kWh (ranging from $213/yr in Washington hydro tiers up to $688/yr in Hawaii)—use the custom rate slider above for your utility tariff.
What are the main drawbacks of GE Profile PJ65S10FPY01 (3.4 UEF)?
GE Profile PJ65S10FPY01 requires >=450 cu ft air space, 120V electrical supply, and drain access; tight interior alcoves favor ducted adapters or Cala Systems, Inc RDH6524M1.
What hot-water delivery rating governs GE Profile PJ65S10FPY01?
Rated for 77 gal FHR (+5 gal vs. 72 gal median), GE Profile PJ65S10FPY01 prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.
Where do homeowners screen GE Profile PJ65S10FPY01 for recalls and tank age?
Verified clean against 2026-11-23 CPSC recall feeds for GE Profile; use our browser-only serial decoder to inspect GE Profile PJ65S10FPY01's age and warranty window.
What alternative models sit closest to GE Profile PJ65S10FPY01 in the Hybrid/Electric Heat Pump class?
Closest peer in Hybrid/Electric Heat Pump is Cala Systems, Inc RDH6524M1 (3.61 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
- EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)