Skip to main content
ENERGY STAR water heater model · PD 4529614

Giant GTHPCO-45 1**+GTXST-50LBTTP 1* Water Heater Specifications (3.55 UEF)

In the 706-unit Hybrid/Electric Heat Pump class, Giant GTHPCO-45 1**+GTXST-50LBTTP 1* (Electric) achieves a certified 3.55 UEF rating across its 48-gallon nominal tank, 72 gal First Hour Rating (rank #414 of 706, PD 4529614) and verifies as Pass: +1.25 / +54.3% for 2029 DOE floors. Rated annual electricity draw of 915 kWh/yr equates to roughly $166/yr ($1,662 over 10 years) at 18.16 cents/kWh. Closest certified alternative is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

Uniform Energy Factor
3.55 UEF
Cohort UEF Rank
#414 of 706
First Hour Rating
72 gal
Storage Volume
48 gal
Fuel / Type
Electric / Hybrid/Electric Heat Pump
DOE 2029 Rule Status
Pass: +1.25 / +54.3%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units)Distribution of certified UEF ratings across 706 units in Hybrid/Electric Heat Pump, marking Giant GTHPCO-45 1**+GTXST-50LBTTP 1* at 3.55 UEF.21130201631342031241542.52 UEF4.50 UEFMedian 3.702029 min 2.30Giant GTHPCO-45 1**+GTXST-50LBTTP 1*: 3.55
Hybrid/Electric Heat Pump UEF Efficiency Distribution (706 Certified Units). Highlighted pin shows Giant GTHPCO-45 1**+GTXST-50LBTTP 1* relative to the cohort median.
Efficiency comparison & rule summary

Giant GTHPCO-45 1**+GTXST-50LBTTP 1* records 3.55 UEF efficiency, putting it #414 of 706 among 706 Hybrid/Electric Heat Pump peers.

10 CFR 430.32(d)(2) compliance: Giant GTHPCO-45 1**+GTXST-50LBTTP 1* exceeds 10 CFR 430.32(d)(2) Electric >35 to <=55 gal (2.30 UEF) by +1.25 UEF (+54.3%). At EIA August 2026 national rates (18.16 cents/kWh), 915 kWh/yr for Giant GTHPCO-45 1**+GTXST-50LBTTP 1* runs ~$166/yr vs. ~$641/yr for a 0.92 UEF electric tank.

State electric sensitivity for Giant GTHPCO-45 1**+GTXST-50LBTTP 1*: 10-year operating spend spans $1,339 in Washington (Lowest Hydro Tier) (14.63 cents/kWh) to $4,317 in Hawaii (Highest EIA State) (47.18 cents/kWh).

Competing options beside Giant GTHPCO-45 1**+GTXST-50LBTTP 1* (3.55 UEF) are A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF, at parity) and American MHPCO-45 1**+MXST-50LBTTP 1** (3.55 UEF, at parity).

Which Specs Set Giant GTHPCO-45 1**+GTXST-50LBTTP 1* Apart From Cohort Averages?

Ranked #414 of 706 inside the 706-model Hybrid/Electric Heat Pump cohort, Giant GTHPCO-45 1**+GTXST-50LBTTP 1* is evaluated row by row below against category medians.

Certified model attributes compared against 706 ENERGY STAR Hybrid/Electric Heat Pump peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandGiant12 certified listingsENERGY STAR PD 4529614
Model NumberGTHPCO-45 1**+GTXST-50LBTTP 1*Draw pattern: Medium-UsageGTHPCO-45 1**+GTXST-50LBTTP 1*
Uniform Energy Factor (UEF)3.55-0.15 UEF vs. 3.70 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)72 galAt 72 gal median10 CFR 430 Recovery Test
Rated Annual Electricity Use915 kWh/yr-157 kWh/yr vs. 1,072 kWh/yr medianEst. $166/yr @ $0.1816/kWh (EIA US Avg)
Thermal Recovery Efficiency428%-1.0 pts vs. 429.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)33" H x 22.5" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" D)Doorway & ceiling check
Electrical Circuit Requirements240 V / 20.2 A maxRequires 240V dedicated branch circuit; check panel capacityNEC / Branch circuit check
Heat Pump Refrigerant & GWPR-744 (CO₂) (GWP:1 | Lower GWP)Lower-GWP refrigerant alignment (EPA AIM Act)EPA AIM Act Compliance
Certification Date2026-03-24Certified 2026-03-24Markets: United States, Canada

How Do Regional kWh Prices Impact GTHPCO-45 1**+GTXST-50LBTTP 1* Over 10 Years?

Using EIA Table 5.6.A benchmarks, Giant GTHPCO-45 1**+GTXST-50LBTTP 1*'s 915 kWh/yr draw translates to roughly $166/yr on typical US residential bills.

Estimated Annual Electricity Cost by State Rate (915 kWh/yr)Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.United States Average$166.00/yrHawaii$432.00/yrCalifornia$272.00/yrTexas$146.00/yrWashington$134.00/yr
Projected annual electricity spend across five benchmark EIA August 2026 residential electric tiers.
Estimated electricity cost and 10-year spend across benchmark states
Jurisdiction (EIA Aug 2026)Residential RateAnnual Cost10-Yr Operating Spend10-Yr Savings vs. 0.92 UEF
United States Average 18.16 ¢/kWh ($0.1816) $166/yr $1,662 $4,751
Hawaii (Highest EIA State) 47.18 ¢/kWh ($0.4718) $432/yr $4,317 $12,342
California 29.75 ¢/kWh ($0.2975) $272/yr $2,722 $7,783
Texas 15.91 ¢/kWh ($0.1591) $146/yr $1,456 $4,162
Washington (Lowest Hydro Tier) 14.63 ¢/kWh ($0.1463) $134/yr $1,339 $3,827
Estimated electricity spend (915 kWh/yr)

Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Giant Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Giant; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Hybrid/Electric Heat Pump Models Stack Up?

Five alternative Hybrid/Electric Heat Pump units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (at parity) 915
American MHPCO-45 1**+MXST-50LBTTP 1** Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (at parity) 915
GSW WATER HEATERS GHPCO-45 1**+GXST-50LBTTP 1** Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (at parity) 915
John Wood JWHPCO-45 1**+JWXST-50LBTTP 1* Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (at parity) 915
A. O. Smith HPACO-45C 1**+AXST-50LBCTTP 1* Hybrid/Electric Heat Pump 48 gal 72 gal 3.55 (at parity) 915

Which Home Setups Are NOT a Fit for Giant GTHPCO-45 1**+GTXST-50LBTTP 1*?

Comparing Giant GTHPCO-45 1**+GTXST-50LBTTP 1* against A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Giant GTHPCO-45 1**+GTXST-50LBTTP 1* needs >=450 cu ft room air volume or ducting so compressor cooling does not stall recovery.
  • Compressor runs near 49 dBA; avoid mounting Giant GTHPCO-45 1**+GTXST-50LBTTP 1* directly beside quiet bedrooms.
  • Requires condensate drain routing and 240V electrical capacity; verify state DOE HEAR status.

Which Option Fits Your Situation?

High Electric Rate States Choosing Giant GTHPCO-45 1**+GTXST-50LBTTP 1* Strong Fit — 3.55 UEF trims electric use ~75% vs 0.92 UEF tanks.
Open Basement or Garage (>=450 cu ft) Strong Fit — Ample ambient air sustains heat-pump-only efficiency.
Small Interior Closet (<300 cu ft) Caution — Add duct kit or compare A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** footprint.

Frequently Asked Technical Questions: Giant GTHPCO-45 1**+GTXST-50LBTTP 1*

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Giant GTHPCO-45 1**+GTXST-50LBTTP 1* score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Giant GTHPCO-45 1**+GTXST-50LBTTP 1* logs 3.55 UEF (Pass: +1.25 / +54.3%) within the 706-unit Hybrid/Electric Heat Pump group.

What physical clearance dimensions apply when installing Giant GTHPCO-45 1**+GTXST-50LBTTP 1*?

With a 33 in. height and 22.5 in. diameter, Giant GTHPCO-45 1**+GTXST-50LBTTP 1* fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22.5" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits Giant GTHPCO-45 1**+GTXST-50LBTTP 1*?

Powered via 240V at 20.2A max, Giant GTHPCO-45 1**+GTXST-50LBTTP 1* requires: Requires 240V dedicated branch circuit; check panel capacity. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Giant GTHPCO-45 1**+GTXST-50LBTTP 1*?

Annual electric spend for Giant GTHPCO-45 1**+GTXST-50LBTTP 1* (915 kWh/yr) averages $166/yr nationwide (ranging from $134/yr in Washington hydro tiers up to $432/yr in Hawaii), calculated directly from August 2026 EIA Table 5.6.A tariffs.

What homeowner setups should avoid choosing Giant GTHPCO-45 1**+GTXST-50LBTTP 1*?

Homes lacking a condensate drain or 240V branch circuit—or unconditioned sub-zero spaces—should verify hybrid backup mode limits on Giant GTHPCO-45 1**+GTXST-50LBTTP 1*.

Is Giant GTHPCO-45 1**+GTXST-50LBTTP 1* sized adequately for a 2-to-4-person household?

ENERGY STAR certifies Giant GTHPCO-45 1**+GTXST-50LBTTP 1* at 72 gal First Hour Rating (At 72 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does Giant have active CPSC SaferProducts notices affecting GTHPCO-45 1**+GTXST-50LBTTP 1*?

Zero CPSC recall alerts matched Giant (2026-11-23 check). Keep your Giant GTHPCO-45 1**+GTXST-50LBTTP 1* serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Giant GTHPCO-45 1**+GTXST-50LBTTP 1* (3.55 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Giant GTHPCO-45 1**+GTXST-50LBTTP 1*. Closest peer in Hybrid/Electric Heat Pump is A. O. Smith HPACO-45 1**+AXST-50LBTTP 1** (3.55 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)
  4. EIA Electric Power Monthly Table 5.6.A — Average Residential Electricity Price by State — U.S. Energy Information Administration (EIA), August 2026 Monthly Release (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks