Skip to main content
ENERGY STAR water heater model · PD 2862479

John Wood JTHR-160M 1** Water Heater Specifications (0.95 UEF)

In the 464-unit Gas Tankless class, John Wood JTHR-160M 1** (Natural Gas, Propane) achieves a certified 0.95 UEF rating (rank #159 of 464, PD 2862479) and verifies as Pass: +0.04 / +4.4% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas, Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking John Wood JTHR-160M 1** at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91John Wood JTHR-160M 1**: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows John Wood JTHR-160M 1** relative to the cohort median.
Efficiency comparison & rule summary

John Wood JTHR-160M 1** records 0.95 UEF efficiency, putting it #159 of 464 among 464 Gas Tankless peers.

DOE 2029 compliance check: John Wood JTHR-160M 1** sits +0.04 UEF (+4.4%) above 0.91 UEF; thermal recovery tests at 98% (At 98.0% median).

Competing options beside John Wood JTHR-160M 1** (0.95 UEF) are A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity).

How Complete Are the Certified Metrics for John Wood JTHR-160M 1**?

Standing at #159 of 464 among 464 certified Gas Tankless heaters, John Wood JTHR-160M 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandJohn Wood17 certified listingsENERGY STAR PD 2862479
Model NumberJTHR-160M 1**Draw pattern: High-UsageJTHR-160M 1**
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency98%At 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2023-12-18Certified 2023-12-18Markets: Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are John Wood Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched John Wood in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to JTHR-160M 1**?

Ordered by minimal capacity and UEF spread relative to John Wood JTHR-160M 1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

Which Home Setups Are NOT a Fit for John Wood JTHR-160M 1**?

Comparing John Wood JTHR-160M 1** against A. O. Smith ACT-199O-N 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Converting a 40K tank to John Wood JTHR-160M 1** often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect John Wood JTHR-160M 1**'s heat exchanger.
  • Condensing John Wood JTHR-160M 1** requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — John Wood JTHR-160M 1** delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Practical Specs & Code Questions for John Wood JTHR-160M 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does John Wood JTHR-160M 1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; John Wood JTHR-160M 1** logs 0.95 UEF (Pass: +0.04 / +4.4%) within the 464-unit Gas Tankless group.

What physical clearance dimensions apply when installing John Wood JTHR-160M 1**?

Because John Wood JTHR-160M 1** is a gas tankless unit (wall-hung / compact envelope), check wall-stud backing, condensate neutralizer routing, and outdoor vent clearances first.

What 240V circuit or IFGC fuel line capacity fits John Wood JTHR-160M 1**?

John Wood JTHR-160M 1** utilizes Natural Gas, Propane combustion (120V AC ignition/fan + gas piping check). Confirm static/dynamic manifold pressure and 120V GFCI outlet availability before swapping out an older storage tank.

How do state electricity prices change annual costs for John Wood JTHR-160M 1**?

John Wood JTHR-160M 1** operates on Natural Gas, Propane (0.95 UEF); check regional therm costs and hot-water recirculation schedules since tankless standby electricity stays minimal.

What homeowner setups should avoid choosing John Wood JTHR-160M 1**?

Northern homes with 40–45 °F winter groundwater see reduced simultaneous GPM output from John Wood JTHR-160M 1**, while hard water >7.0 GPG demands annual vinegar flushing.

Is John Wood JTHR-160M 1** sized adequately for a 2-to-4-person household?

Instead of First Hour Rating, John Wood JTHR-160M 1** heats water continuously; two concurrent 2.0 GPM showers and a faucet require ~5.5 GPM at a 70 °F temperature rise.

Does John Wood have active CPSC SaferProducts notices affecting JTHR-160M 1**?

Zero CPSC recall alerts matched John Wood (2026-11-23 check). Keep your John Wood JTHR-160M 1** serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches John Wood JTHR-160M 1** (0.95 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for John Wood JTHR-160M 1**. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks