Skip to main content
ENERGY STAR water heater model · PD 2862527

John Wood JTHR-180M 1** Water Heater Specifications (0.95 UEF)

Engineered as a Natural Gas, Propane Gas Tankless unit, John Wood JTHR-180M 1** achieves a certified 0.95 UEF rating and ranks #159 of 464 in its 464-model cohort (PD 2862527), recording Pass: +0.04 / +4.4% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas, Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking John Wood JTHR-180M 1** at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91John Wood JTHR-180M 1**: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows John Wood JTHR-180M 1** relative to the cohort median.
Efficiency comparison & rule summary

Within the 464-unit Gas Tankless cohort, John Wood JTHR-180M 1** logs 0.95 UEF and ranks #159 of 464.

John Wood JTHR-180M 1** delivers +0.04 UEF (+4.4%) margin above the 0.91 UEF Natural Gas, Propane tankless mandate; thermal recovery tests at 97% (-1.0 pts vs. 98.0% median).

Cross-shopping John Wood JTHR-180M 1** (0.95 UEF)? Check A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity).

Where Does John Wood JTHR-180M 1** Rank Against Peer Gas Tankless Units?

Audited against 464 ENERGY STAR Gas Tankless listings, John Wood JTHR-180M 1** holds #159 of 464; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandJohn Wood17 certified listingsENERGY STAR PD 2862527
Model NumberJTHR-180M 1**Draw pattern: High-UsageJTHR-180M 1**
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency97%-1.0 pts vs. 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2023-12-18Certified 2023-12-18Markets: Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on John Wood Units?

No open CPSC recall alerts appeared for John Wood as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Gas Tankless Models Compare Closest to JTHR-180M 1**?

Compare five nearby ENERGY STAR Gas Tankless options matched closely to John Wood JTHR-180M 1**'s gallon capacity and 0.95 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

When Should Homeowners Skip John Wood JTHR-180M 1** (Gas Tankless)?

Check John Wood JTHR-180M 1**'s mechanical constraints—including utility space, Natural Gas, Propane capacity, and Pass: +0.04 / +4.4% status—against typical residential installations.

Key Limitations & Exclusions

  • Converting a 40K tank to John Wood JTHR-180M 1** often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect John Wood JTHR-180M 1**'s heat exchanger.
  • Condensing John Wood JTHR-180M 1** requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — John Wood JTHR-180M 1** delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Common Homeowner Questions for John Wood JTHR-180M 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will John Wood JTHR-180M 1** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.95 UEF, John Wood JTHR-180M 1** shows Pass: +0.04 / +4.4% relative to May 6, 2029 federal DOE limits while placing #159 of 464 among 464 Gas Tankless peers like A. O. Smith ACT-199O-N 1**.

Will John Wood JTHR-180M 1** fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted gas tankless chassis, John Wood JTHR-180M 1** eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

Do existing utility hookups support John Wood JTHR-180M 1** during replacement?

Fueled by Natural Gas, Propane, John Wood JTHR-180M 1** specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

What is the estimated 10-year operating spend for John Wood JTHR-180M 1**?

Because John Wood JTHR-180M 1** burns Natural Gas, Propane at 0.95 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 464 peers.

When is John Wood JTHR-180M 1** a poor fit for a residential replacement?

Skip John Wood JTHR-180M 1** as a quick swap when long 1/2 in. iron gas lines starve ignition (triggering E003/11 codes) or when Type B metal chimney vents cannot handle condensing PVC.

What First Hour Rating or flow capacity does John Wood JTHR-180M 1** deliver?

As an on-demand Gas Tankless model, John Wood JTHR-180M 1** has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.

How do you verify manufacturing age and recall status on John Wood JTHR-180M 1**?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for John Wood; verify exact manufacturing week for John Wood JTHR-180M 1** using the Serial Number Lookup tool.

Does John Wood JTHR-180M 1** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for John Wood JTHR-180M 1**. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks