Skip to main content
ENERGY STAR water heater model · PD 4670330

Lochinvar LCTH-199M-(N,P) 1** Water Heater Specifications (0.95 UEF)

The Lochinvar LCTH-199M-(N,P) 1** (Gas Tankless, Natural Gas, Propane) achieves a certified 0.95 UEF rating, ranking #159 of 464 among 464 ENERGY STAR Gas Tankless models (PD 4670330). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.04 / +4.4%. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas, Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Lochinvar LCTH-199M-(N,P) 1** at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Lochinvar LCTH-199M-(N,P) 1**: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Lochinvar LCTH-199M-(N,P) 1** relative to the cohort median.
Efficiency comparison & rule summary

Lochinvar LCTH-199M-(N,P) 1** (0.95 UEF) ranks #159 of 464 Gas Tankless models — 306-way tie; tied at bottom of cohort, at the 0.95 UEF median.

Lochinvar LCTH-199M-(N,P) 1** (Natural Gas, Propane tankless) clears the May 6, 2029 0.91 UEF threshold by +0.04 UEF (+4.4%); thermal recovery tests at 97% (-1.0 pts vs. 98.0% median).

Peer comparison: Lochinvar LCTH-199M-(N,P) 1** (0.95 UEF) compares closely with A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity).

Which Specs Set Lochinvar LCTH-199M-(N,P) 1** Apart From Cohort Averages?

Ranked #159 of 464 inside the 464-model Gas Tankless cohort, Lochinvar LCTH-199M-(N,P) 1** is evaluated row by row below against category medians.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandLochinvar65 certified listingsENERGY STAR PD 4670330
Model NumberLCTH-199M-(N,P) 1**Draw pattern: High-UsageLCTH-199M-(N,P) 1**
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency97%-1.0 pts vs. 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2026-07-15Certified 2026-07-15Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

What Should Lochinvar Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC SaferProducts snapshot includes 1 filing tied to Lochinvar; verify whether your LCTH-199M-(N,P) 1** production run falls inside affected ranges. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)

How Do Five Nearby Gas Tankless Models Stack Up?

Five alternative Gas Tankless units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

Who Is Lochinvar LCTH-199M-(N,P) 1** Best For — and When Should You Pick A. O. Smith ACT-199O-N 1**?

Evaluate whether Lochinvar LCTH-199M-(N,P) 1**'s Gas Tankless architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Converting a 40K tank to Lochinvar LCTH-199M-(N,P) 1** often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Lochinvar LCTH-199M-(N,P) 1**'s heat exchanger.
  • Condensing Lochinvar LCTH-199M-(N,P) 1** requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Lochinvar LCTH-199M-(N,P) 1** delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Frequently Asked Technical Questions: Lochinvar LCTH-199M-(N,P) 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Lochinvar LCTH-199M-(N,P) 1** (0.95 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Lochinvar LCTH-199M-(N,P) 1** records 0.95 UEF (Pass: +0.04 / +4.4%), placing #159 of 464 out of 464 certified Gas Tankless configurations.

Does Lochinvar LCTH-199M-(N,P) 1** fit inside a tight hallway closet or low-headroom utility room?

Designed as a compact gas tankless platform (wall-hung / compact envelope), Lochinvar LCTH-199M-(N,P) 1** still needs code-compliant flue separation from windows and gas meters.

What power supply or fuel line specs govern Lochinvar LCTH-199M-(N,P) 1**?

Installing Lochinvar LCTH-199M-(N,P) 1** on Natural Gas, Propane involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

What annual utility bill should homeowners budget for Lochinvar LCTH-199M-(N,P) 1**?

Rated 0.95 UEF on Natural Gas, Propane, Lochinvar LCTH-199M-(N,P) 1** carries no whole-house kWh heating draw; confirm annual therm usage against 464 Gas Tankless models.

What are the main drawbacks of Lochinvar LCTH-199M-(N,P) 1** (0.95 UEF)?

Homeowners unwilling to perform 12-month scale flushes in >=7.0 GPG water or upgrade 1/2 in. gas piping should weigh A. O. Smith ACT-199O-N 1** or hybrid alternatives.

What hot-water delivery rating governs Lochinvar LCTH-199M-(N,P) 1**?

On-demand Gas Tankless sizing for Lochinvar LCTH-199M-(N,P) 1** depends on winter inlet water temp (typically 45–65 °F) heated to a 120 °F anti-scald setpoint.

Where do homeowners screen Lochinvar LCTH-199M-(N,P) 1** for recalls and tank age?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to Lochinvar LCTH-199M-(N,P) 1** in the Gas Tankless class?

Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks