Lochinvar LTM-199X3-P 1*1 Water Heater Specifications (0.95 UEF)
Certified at 0.95 UEF, Lochinvar LTM-199X3-P 1*1 (Gas Tankless, Propane) places #159 of 464 out of 464 ENERGY STAR models (PD 4617121). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.04 / +4.4%. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).
- Uniform Energy Factor
- 0.95 UEF
- Cohort UEF Rank
- #159 of 464
- First Hour Rating
- On-Demand
- Storage Volume
- Tankless
- Fuel / Type
- Propane / Gas Tankless
- DOE 2029 Rule Status
- Pass: +0.04 / +4.4%

Tested at 0.95 UEF, Lochinvar LTM-199X3-P 1*1 places #159 of 464 across 464 certified Gas Tankless configurations (At 0.95 UEF median).
Operating on Propane, Lochinvar LTM-199X3-P 1*1 beats the 2029 0.91 UEF floor by +0.04 UEF (+4.4%); thermal recovery tests at 96% (-2.0 pts vs. 98.0% median).
Closest alternatives to Lochinvar LTM-199X3-P 1*1 include A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) alongside American GT-240-NEH 1** (0.95 UEF, at parity).
Which Specs Set Lochinvar LTM-199X3-P 1*1 Apart From Cohort Averages?
Ranked #159 of 464 inside the 464-model Gas Tankless cohort, Lochinvar LTM-199X3-P 1*1 is evaluated row by row below against category medians.
| Specification Attribute | Certified Value | Cohort Benchmark / Delta | Provenance |
|---|---|---|---|
| Manufacturer / Brand | Lochinvar | 65 certified listings | ENERGY STAR PD 4617121 |
| Model Number | LTM-199X3-P 1*1 | Draw pattern: High-Usage | LTM-199X3-P 1*1 |
| Uniform Energy Factor (UEF) | 0.95 | At 0.95 UEF median | 10 CFR 430 Test Method |
| Thermal Recovery Efficiency | 96% | -2.0 pts vs. 98.0% median | ENERGY STAR Dataset |
| Electrical Circuit Requirements | 5 A max | 120V AC ignition/fan + gas piping check | NEC / Branch circuit check |
| Certification Date | 2026-05-27 | Certified 2026-05-27 | Markets: United States |
What Should Lochinvar Owners Check in CPSC Recall Logs?
The 2026-11-23 CPSC SaferProducts snapshot includes 1 filing tied to Lochinvar; verify whether your LTM-199X3-P 1*1 production run falls inside affected ranges. See Serial Number Lookup.
- Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
How Do Five Nearby Gas Tankless Models Stack Up?
Five alternative Gas Tankless units with nearly identical gallon storage and UEF scores are listed below alongside exact efficiency spreads.
| Brand & Model | Type | Vol | FHR | UEF (Δ) | kWh/yr |
|---|---|---|---|---|---|
| A. O. Smith ACT-199O-N 1** | Gas Tankless | — | — | 0.95 (at parity) | — |
| American GT-240-NEH 1** | Gas Tankless | — | — | 0.95 (at parity) | — |
| Bosch T9800 SE 160 | Gas Tankless | — | — | 0.95 (at parity) | — |
| Bradford White RTG-K-160N1 | Gas Tankless | — | — | 0.95 (at parity) | — |
| A. O. Smith ACT-199O-P 1*1 | Gas Tankless | — | — | 0.95 (at parity) | — |
What Are the Limitations of Lochinvar LTM-199X3-P 1*1 and Who Should Not Install It?
Before ordering Lochinvar LTM-199X3-P 1*1 (Gas Tankless, 0.95 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.
Key Limitations & Exclusions
- Converting a 40K tank to Lochinvar LTM-199X3-P 1*1 often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
- Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Lochinvar LTM-199X3-P 1*1's heat exchanger.
- Condensing Lochinvar LTM-199X3-P 1*1 requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.
Which Option Fits Your Situation?
Frequently Asked Technical Questions: Lochinvar LTM-199X3-P 1*1
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Does Lochinvar LTM-199X3-P 1*1 pass the May 6, 2029 federal DOE efficiency rule?
Lochinvar LTM-199X3-P 1*1 carries a verified 0.95 UEF rating (Pass: +0.04 / +4.4%), ranking #159 of 464 across 464 ENERGY STAR Gas Tankless models under 10 CFR 430.32.
What doorway width and ceiling height does Lochinvar LTM-199X3-P 1*1 need?
Lochinvar LTM-199X3-P 1*1 mounts as a gas tankless without a bulky floor tank (wall-hung / compact envelope). Verify vent termination distances and combustion air clearances per IPC or UPC.
What gas pipe size or electrical breaker does Lochinvar LTM-199X3-P 1*1 require?
Lochinvar LTM-199X3-P 1*1 runs on Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.
How much electricity or energy does Lochinvar LTM-199X3-P 1*1 cost per year to run?
ENERGY STAR rates Lochinvar LTM-199X3-P 1*1 as a Propane heater (0.95 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas Tankless draw.
Who should NOT install Lochinvar LTM-199X3-P 1*1, and what are its limits?
Lochinvar LTM-199X3-P 1*1 (0.95 UEF) is rarely a drop-in swap over a 40K tank if existing 1/2 in. gas pipe cannot supply 199,000 BTU/h or hardness exceeds 7.0 GPG without descaling.
How many bathrooms or people can Lochinvar LTM-199X3-P 1*1 serve at peak demand?
Lochinvar LTM-199X3-P 1*1 provides continuous Gas Tankless delivery rather than a fixed storage FHR; size GPM flow against winter incoming groundwater temperature and 2.0 GPM showers.
Are there CPSC safety recalls or serial checks for Lochinvar LTM-199X3-P 1*1?
CPSC SaferProducts records show 1 brand-level recall notice mentioning Lochinvar as of 2026-11-23, including #05274 (2005-09-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.
What 2026 rebates apply to Lochinvar LTM-199X3-P 1*1, and what peer compares closest?
Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).
Sources
- ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
- 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
- CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)