Skip to main content
ENERGY STAR water heater model · PD 4480582

Midea JSG40-24PCH-LP Water Heater Specifications (0.95 UEF)

Engineered as a Propane Gas Tankless unit, Midea JSG40-24PCH-LP achieves a certified 0.95 UEF rating and ranks #159 of 464 in its 464-model cohort (PD 4480582), recording Pass: +0.04 / +4.4% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Midea JSG40-24PCH-LP at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Midea JSG40-24PCH-LP: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Midea JSG40-24PCH-LP relative to the cohort median.
Efficiency comparison & rule summary

Within the 464-unit Gas Tankless cohort, Midea JSG40-24PCH-LP logs 0.95 UEF and ranks #159 of 464.

Midea JSG40-24PCH-LP delivers +0.04 UEF (+4.4%) margin above the 0.91 UEF Propane tankless mandate; thermal recovery tests at 96% (-2.0 pts vs. 98.0% median).

Cross-shopping Midea JSG40-24PCH-LP (0.95 UEF)? Check A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity).

What Physical and Thermal Ratings Define Midea JSG40-24PCH-LP?

Positioning at #159 of 464 out of 464 Gas Tankless peers, Midea JSG40-24PCH-LP pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 4480582
Model NumberJSG40-24PCH-LPDraw pattern: High-UsageJSG40-24PCH-LP
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency96%-2.0 pts vs. 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements1.1 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2025-07-15Certified 2025-07-15Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Midea Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Midea; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Midea JSG40-24PCH-LP?

Homeowners cross-shopping Midea JSG40-24PCH-LP frequently review these five Gas Tankless models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

Which Home Setups Are NOT a Fit for Midea JSG40-24PCH-LP?

Comparing Midea JSG40-24PCH-LP against A. O. Smith ACT-199O-N 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Converting a 40K tank to Midea JSG40-24PCH-LP often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Midea JSG40-24PCH-LP's heat exchanger.
  • Condensing Midea JSG40-24PCH-LP requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Midea JSG40-24PCH-LP delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Sizing, Efficiency & Recall Answers for Midea JSG40-24PCH-LP

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Midea JSG40-24PCH-LP score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Midea JSG40-24PCH-LP logs 0.95 UEF (Pass: +0.04 / +4.4%) within the 464-unit Gas Tankless group.

What physical clearance dimensions apply when installing Midea JSG40-24PCH-LP?

Because Midea JSG40-24PCH-LP is a gas tankless unit (wall-hung / compact envelope), check wall-stud backing, condensate neutralizer routing, and outdoor vent clearances first.

What 240V circuit or IFGC fuel line capacity fits Midea JSG40-24PCH-LP?

Midea JSG40-24PCH-LP utilizes Propane combustion (120V AC ignition/fan + gas piping check). Confirm static/dynamic manifold pressure and 120V GFCI outlet availability before swapping out an older storage tank.

How do state electricity prices change annual costs for Midea JSG40-24PCH-LP?

Midea JSG40-24PCH-LP operates on Propane (0.95 UEF); check regional therm costs and hot-water recirculation schedules since tankless standby electricity stays minimal.

What homeowner setups should avoid choosing Midea JSG40-24PCH-LP?

Northern homes with 40–45 °F winter groundwater see reduced simultaneous GPM output from Midea JSG40-24PCH-LP, while hard water >7.0 GPG demands annual vinegar flushing.

Is Midea JSG40-24PCH-LP sized adequately for a 2-to-4-person household?

Instead of First Hour Rating, Midea JSG40-24PCH-LP heats water continuously; two concurrent 2.0 GPM showers and a faucet require ~5.5 GPM at a 70 °F temperature rise.

Does Midea have active CPSC SaferProducts notices affecting JSG40-24PCH-LP?

Zero CPSC recall alerts matched Midea (2026-11-23 check). Keep your Midea JSG40-24PCH-LP serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Midea JSG40-24PCH-LP (0.95 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Midea JSG40-24PCH-LP. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks