Skip to main content
ENERGY STAR water heater model · PD 3626984

Midea JSG48-29PCH-LP Water Heater Specifications (0.95 UEF)

In the 464-unit Gas Tankless class, Midea JSG48-29PCH-LP (Propane) achieves a certified 0.95 UEF rating (rank #159 of 464, PD 3626984) and verifies as Pass: +0.04 / +4.4% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Midea JSG48-29PCH-LP at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Midea JSG48-29PCH-LP: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Midea JSG48-29PCH-LP relative to the cohort median.
Efficiency comparison & rule summary

Midea JSG48-29PCH-LP records 0.95 UEF efficiency, putting it #159 of 464 among 464 Gas Tankless peers.

DOE 2029 compliance check: Midea JSG48-29PCH-LP sits +0.04 UEF (+4.4%) above 0.91 UEF; thermal recovery tests at 99% (+1.0 pts vs. 98.0% median).

Competing options beside Midea JSG48-29PCH-LP (0.95 UEF) are A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity).

How Complete Are the Certified Metrics for Midea JSG48-29PCH-LP?

Standing at #159 of 464 among 464 certified Gas Tankless heaters, Midea JSG48-29PCH-LP brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 3626984
Model NumberJSG48-29PCH-LPDraw pattern: High-UsageJSG48-29PCH-LP
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency99%+1.0 pts vs. 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements1.3 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-03-18Certified 2024-03-18Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Midea Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Midea in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to JSG48-29PCH-LP?

Ordered by minimal capacity and UEF spread relative to Midea JSG48-29PCH-LP, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

What Installation Caveats Apply Before Buying Midea JSG48-29PCH-LP?

Even high-UEF units like Midea JSG48-29PCH-LP (0.95 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Converting a 40K tank to Midea JSG48-29PCH-LP often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Midea JSG48-29PCH-LP's heat exchanger.
  • Condensing Midea JSG48-29PCH-LP requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Midea JSG48-29PCH-LP delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Practical Specs & Code Questions for Midea JSG48-29PCH-LP

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Midea JSG48-29PCH-LP eligible for continued manufacture past May 6, 2029?

At 0.95 UEF, Midea JSG48-29PCH-LP achieves Pass: +0.04 / +4.4% for the 2029 DOE standard and stands #159 of 464 against A. O. Smith ACT-199O-N 1** and American GT-240-NEH 1**.

How tall and wide is Midea JSG48-29PCH-LP, and what service clearance is needed?

Midea JSG48-29PCH-LP saves floor space via its gas tankless layout (wall-hung / compact envelope); inspect service-valve swing clearance below the bottom manifold.

Will Midea JSG48-29PCH-LP require upgrading household electrical panels or gas piping?

Check Propane piping and venting for Midea JSG48-29PCH-LP (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.

Is Midea JSG48-29PCH-LP economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for Midea JSG48-29PCH-LP (Propane, 0.95 UEF) hinge on household gallon demand and local gas utility tariffs compared with A. O. Smith ACT-199O-N 1**.

Which installation bottlenecks limit Midea JSG48-29PCH-LP?

Without 3/4 in.–1 in. IFGC gas sizing and Category IV PVC exhaust routing, Midea JSG48-29PCH-LP requires added mechanical rework over standard tank replacements.

How does Midea JSG48-29PCH-LP handle simultaneous showers and laundry?

Midea JSG48-29PCH-LP supplies endless hot water within its maximum BTU/flow curve—check cold-climate winter groundwater temperatures before running 3+ fixtures at once.

How long is the warranty on Midea JSG48-29PCH-LP and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Midea as of 2026-11-23. Confirm install proof and serial manufacture year on Midea JSG48-29PCH-LP before calling service.

How do 2026 post-OBBBA rebates affect buying Midea JSG48-29PCH-LP?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)