Skip to main content
ENERGY STAR water heater model · PD 3626986

Midea JSG48-29PCHP-LP Water Heater Specifications (0.95 UEF)

Certified at 0.95 UEF, Midea JSG48-29PCHP-LP (Gas Tankless, Propane) places #159 of 464 out of 464 ENERGY STAR models (PD 3626986). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.04 / +4.4%. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Midea JSG48-29PCHP-LP at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Midea JSG48-29PCHP-LP: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Midea JSG48-29PCHP-LP relative to the cohort median.
Efficiency comparison & rule summary

Tested at 0.95 UEF, Midea JSG48-29PCHP-LP places #159 of 464 across 464 certified Gas Tankless configurations (At 0.95 UEF median).

Operating on Propane, Midea JSG48-29PCHP-LP beats the 2029 0.91 UEF floor by +0.04 UEF (+4.4%); thermal recovery tests at 99% (+1.0 pts vs. 98.0% median).

Closest alternatives to Midea JSG48-29PCHP-LP include A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) alongside American GT-240-NEH 1** (0.95 UEF, at parity).

Where Does Midea JSG48-29PCHP-LP Rank Against Peer Gas Tankless Units?

Audited against 464 ENERGY STAR Gas Tankless listings, Midea JSG48-29PCHP-LP holds #159 of 464; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 3626986
Model NumberJSG48-29PCHP-LPDraw pattern: High-UsageJSG48-29PCHP-LP
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency99%+1.0 pts vs. 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements1.3 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-03-18Certified 2024-03-18Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Midea Units?

No open CPSC recall alerts appeared for Midea as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Gas Tankless Models Compare Closest to JSG48-29PCHP-LP?

Compare five nearby ENERGY STAR Gas Tankless options matched closely to Midea JSG48-29PCHP-LP's gallon capacity and 0.95 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

When Should Homeowners Skip Midea JSG48-29PCHP-LP (Gas Tankless)?

Check Midea JSG48-29PCHP-LP's mechanical constraints—including utility space, Propane capacity, and Pass: +0.04 / +4.4% status—against typical residential installations.

Key Limitations & Exclusions

  • Converting a 40K tank to Midea JSG48-29PCHP-LP often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Midea JSG48-29PCHP-LP's heat exchanger.
  • Condensing Midea JSG48-29PCHP-LP requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Midea JSG48-29PCHP-LP delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Common Homeowner Questions for Midea JSG48-29PCHP-LP

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Midea JSG48-29PCHP-LP stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.95 UEF, Midea JSG48-29PCHP-LP shows Pass: +0.04 / +4.4% relative to May 6, 2029 federal DOE limits while placing #159 of 464 among 464 Gas Tankless peers like A. O. Smith ACT-199O-N 1**.

Will Midea JSG48-29PCHP-LP fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted gas tankless chassis, Midea JSG48-29PCHP-LP eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

Do existing utility hookups support Midea JSG48-29PCHP-LP during replacement?

Fueled by Propane, Midea JSG48-29PCHP-LP specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

What is the estimated 10-year operating spend for Midea JSG48-29PCHP-LP?

Because Midea JSG48-29PCHP-LP burns Propane at 0.95 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 464 peers.

When is Midea JSG48-29PCHP-LP a poor fit for a residential replacement?

Skip Midea JSG48-29PCHP-LP as a quick swap when long 1/2 in. iron gas lines starve ignition (triggering E003/11 codes) or when Type B metal chimney vents cannot handle condensing PVC.

What First Hour Rating or flow capacity does Midea JSG48-29PCHP-LP deliver?

As an on-demand Gas Tankless model, Midea JSG48-29PCHP-LP has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.

How do you verify manufacturing age and recall status on Midea JSG48-29PCHP-LP?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Midea; verify exact manufacturing week for Midea JSG48-29PCHP-LP using the Serial Number Lookup tool.

Does Midea JSG48-29PCHP-LP qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Midea JSG48-29PCHP-LP. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).