Skip to main content
ENERGY STAR water heater model · PD 3629346

Midea JSG52-32PCHP-LP Water Heater Specifications (0.95 UEF)

Certified at 0.95 UEF, Midea JSG52-32PCHP-LP (Gas Tankless, Propane) places #159 of 464 out of 464 ENERGY STAR models (PD 3629346). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.04 / +4.4%. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Midea JSG52-32PCHP-LP at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Midea JSG52-32PCHP-LP: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Midea JSG52-32PCHP-LP relative to the cohort median.
Efficiency comparison & rule summary

Tested at 0.95 UEF, Midea JSG52-32PCHP-LP places #159 of 464 across 464 certified Gas Tankless configurations (At 0.95 UEF median).

Operating on Propane, Midea JSG52-32PCHP-LP beats the 2029 0.91 UEF floor by +0.04 UEF (+4.4%); thermal recovery tests at 99% (+1.0 pts vs. 98.0% median).

Closest alternatives to Midea JSG52-32PCHP-LP include A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) alongside American GT-240-NEH 1** (0.95 UEF, at parity).

How Do Midea JSG52-32PCHP-LP Specs Compare to Gas Tankless Medians?

Midea JSG52-32PCHP-LP places #159 of 464 across 464 certified Gas Tankless configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandMidea49 certified listingsENERGY STAR PD 3629346
Model NumberJSG52-32PCHP-LPDraw pattern: High-UsageJSG52-32PCHP-LP
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency99%+1.0 pts vs. 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements1.3 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-03-18Certified 2024-03-18Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Midea Water Heaters?

Zero active CPSC recalls matched Midea in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match JSG52-32PCHP-LP Most Closely?

These 5 competing Gas Tankless units sit nearest to Midea JSG52-32PCHP-LP by storage capacity and 0.95 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

What Installation Caveats Apply Before Buying Midea JSG52-32PCHP-LP?

Even high-UEF units like Midea JSG52-32PCHP-LP (0.95 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Converting a 40K tank to Midea JSG52-32PCHP-LP often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Midea JSG52-32PCHP-LP's heat exchanger.
  • Condensing Midea JSG52-32PCHP-LP requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Midea JSG52-32PCHP-LP delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

What Are the Key Questions About Midea JSG52-32PCHP-LP?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Midea JSG52-32PCHP-LP eligible for continued manufacture past May 6, 2029?

At 0.95 UEF, Midea JSG52-32PCHP-LP achieves Pass: +0.04 / +4.4% for the 2029 DOE standard and stands #159 of 464 against A. O. Smith ACT-199O-N 1** and American GT-240-NEH 1**.

How tall and wide is Midea JSG52-32PCHP-LP, and what service clearance is needed?

Midea JSG52-32PCHP-LP saves floor space via its gas tankless layout (wall-hung / compact envelope); inspect service-valve swing clearance below the bottom manifold.

Will Midea JSG52-32PCHP-LP require upgrading household electrical panels or gas piping?

Check Propane piping and venting for Midea JSG52-32PCHP-LP (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.

Is Midea JSG52-32PCHP-LP economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for Midea JSG52-32PCHP-LP (Propane, 0.95 UEF) hinge on household gallon demand and local gas utility tariffs compared with A. O. Smith ACT-199O-N 1**.

Which installation bottlenecks limit Midea JSG52-32PCHP-LP?

Without 3/4 in.–1 in. IFGC gas sizing and Category IV PVC exhaust routing, Midea JSG52-32PCHP-LP requires added mechanical rework over standard tank replacements.

How does Midea JSG52-32PCHP-LP handle simultaneous showers and laundry?

Midea JSG52-32PCHP-LP supplies endless hot water within its maximum BTU/flow curve—check cold-climate winter groundwater temperatures before running 3+ fixtures at once.

How long is the warranty on Midea JSG52-32PCHP-LP and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Midea as of 2026-11-23. Confirm install proof and serial manufacture year on Midea JSG52-32PCHP-LP before calling service.

How do 2026 post-OBBBA rebates affect buying Midea JSG52-32PCHP-LP?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks