Skip to main content
ENERGY STAR water heater model · PD 2408716

Noritz EZ98DV (GQ-C2860WX-FF US) Water Heater Specifications (0.96 UEF)

Certified at 0.96 UEF, Noritz EZ98DV (GQ-C2860WX-FF US) (Gas Tankless, Natural Gas, Propane) places #39 of 464 out of 464 ENERGY STAR models (PD 2408716). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.05 / +5.5%. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is Bradford White RTGR199N1** (0.96 UEF).

Uniform Energy Factor
0.96 UEF
Cohort UEF Rank
#39 of 464 (top 34.1%)
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas, Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.05 / +5.5%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Noritz EZ98DV (GQ-C2860WX-FF US) at 0.96 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Noritz EZ98DV (GQ-C2860WX-FF US): 0.96
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Noritz EZ98DV (GQ-C2860WX-FF US) relative to the cohort median.
Efficiency comparison & rule summary

Tested at 0.96 UEF, Noritz EZ98DV (GQ-C2860WX-FF US) places #39 of 464 across 464 certified Gas Tankless configurations (+0.01 UEF vs. 0.95 UEF median).

Operating on Natural Gas, Propane, Noritz EZ98DV (GQ-C2860WX-FF US) beats the 2029 0.91 UEF floor by +0.05 UEF (+5.5%).

Closest alternatives to Noritz EZ98DV (GQ-C2860WX-FF US) include Bradford White RTGR199N1** (0.96 UEF, at parity) alongside Friedrich FDTGH-S10I (0.96 UEF, at parity).

Where Does Noritz EZ98DV (GQ-C2860WX-FF US) Rank Against Peer Gas Tankless Units?

Audited against 464 ENERGY STAR Gas Tankless listings, Noritz EZ98DV (GQ-C2860WX-FF US) holds #39 of 464 (top 34.1%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandNoritz23 certified listingsENERGY STAR PD 2408716
Model NumberEZ98DV (GQ-C2860WX-FF US)Draw pattern: High-UsageEZ98DV (GQ-C2860WX-FF US)
Uniform Energy Factor (UEF)0.96+0.01 UEF vs. 0.95 UEF median10 CFR 430 Test Method
Electrical Circuit Requirements0.6 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Noritz Units?

No open CPSC recall alerts appeared for Noritz as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Gas Tankless Models Compare Closest to EZ98DV (GQ-C2860WX-FF US)?

Compare five nearby ENERGY STAR Gas Tankless options matched closely to Noritz EZ98DV (GQ-C2860WX-FF US)'s gallon capacity and 0.96 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Bradford White RTGR199N1** Gas Tankless — — 0.96 (at parity) —
Friedrich FDTGH-S10I Gas Tankless — — 0.96 (at parity) —
Kepler JSG48-29PCH/180K Gas Tankless — — 0.96 (at parity) —
Kings Peak KNG199ICW Gas Tankless — — 0.96 (at parity) —
Bradford White RTGR199X1** Gas Tankless — — 0.96 (at parity) —

Which Home Setups Are NOT a Fit for Noritz EZ98DV (GQ-C2860WX-FF US)?

Comparing Noritz EZ98DV (GQ-C2860WX-FF US) against Bradford White RTGR199N1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Converting a 40K tank to Noritz EZ98DV (GQ-C2860WX-FF US) often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Noritz EZ98DV (GQ-C2860WX-FF US)'s heat exchanger.
  • Condensing Noritz EZ98DV (GQ-C2860WX-FF US) requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Noritz EZ98DV (GQ-C2860WX-FF US) delivers continuous 0.96 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Common Homeowner Questions for Noritz EZ98DV (GQ-C2860WX-FF US)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Noritz EZ98DV (GQ-C2860WX-FF US) score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; Noritz EZ98DV (GQ-C2860WX-FF US) logs 0.96 UEF (Pass: +0.05 / +5.5%) within the 464-unit Gas Tankless group.

What physical clearance dimensions apply when installing Noritz EZ98DV (GQ-C2860WX-FF US)?

Because Noritz EZ98DV (GQ-C2860WX-FF US) is a gas tankless unit (wall-hung / compact envelope), check wall-stud backing, condensate neutralizer routing, and outdoor vent clearances first.

What 240V circuit or IFGC fuel line capacity fits Noritz EZ98DV (GQ-C2860WX-FF US)?

Noritz EZ98DV (GQ-C2860WX-FF US) utilizes Natural Gas, Propane combustion (120V AC ignition/fan + gas piping check). Confirm static/dynamic manifold pressure and 120V GFCI outlet availability before swapping out an older storage tank.

How do state electricity prices change annual costs for Noritz EZ98DV (GQ-C2860WX-FF US)?

Noritz EZ98DV (GQ-C2860WX-FF US) operates on Natural Gas, Propane (0.96 UEF); check regional therm costs and hot-water recirculation schedules since tankless standby electricity stays minimal.

What homeowner setups should avoid choosing Noritz EZ98DV (GQ-C2860WX-FF US)?

Northern homes with 40–45 °F winter groundwater see reduced simultaneous GPM output from Noritz EZ98DV (GQ-C2860WX-FF US), while hard water >7.0 GPG demands annual vinegar flushing.

Is Noritz EZ98DV (GQ-C2860WX-FF US) sized adequately for a 2-to-4-person household?

Instead of First Hour Rating, Noritz EZ98DV (GQ-C2860WX-FF US) heats water continuously; two concurrent 2.0 GPM showers and a faucet require ~5.5 GPM at a 70 °F temperature rise.

Does Noritz have active CPSC SaferProducts notices affecting EZ98DV (GQ-C2860WX-FF US)?

Zero CPSC recall alerts matched Noritz (2026-11-23 check). Keep your Noritz EZ98DV (GQ-C2860WX-FF US) serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Noritz EZ98DV (GQ-C2860WX-FF US) (0.96 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Noritz EZ98DV (GQ-C2860WX-FF US). Closest peer in Gas Tankless is Bradford White RTGR199N1** (0.96 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks