Skip to main content
ENERGY STAR water heater model · PD 3629794

Noritz NCC199CDV (GQ-C3261WZ-FF US) Water Heater Specifications (0.98 UEF)

In the 464-unit Gas Tankless class, Noritz NCC199CDV (GQ-C3261WZ-FF US) (Natural Gas, Propane) achieves a certified 0.98 UEF rating (rank #1 of 464, PD 3629794) and verifies as Pass: +0.07 / +7.7% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.1" d). Closest certified alternative is Bradford White RTGR150N1 (0.98 UEF).

Uniform Energy Factor
0.98 UEF
Cohort UEF Rank
#1 of 464 (top 7.1%)
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas, Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.07 / +7.7%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Noritz NCC199CDV (GQ-C3261WZ-FF US) at 0.98 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Noritz NCC199CDV (GQ-C3261WZ-FF US): 0.98
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Noritz NCC199CDV (GQ-C3261WZ-FF US) relative to the cohort median.
Efficiency comparison & rule summary

Noritz NCC199CDV (GQ-C3261WZ-FF US) records 0.98 UEF efficiency, putting it #1 of 464 among 464 Gas Tankless peers.

DOE 2029 compliance check: Noritz NCC199CDV (GQ-C3261WZ-FF US) sits +0.07 UEF (+7.7%) above 0.91 UEF; thermal recovery tests at 98% (At 98.0% median).

Competing options beside Noritz NCC199CDV (GQ-C3261WZ-FF US) (0.98 UEF) are Bradford White RTGR150N1 (0.98 UEF, at parity) and JUNSKY, CAMPLUX, GASLAND, ThermoMate RP*199iB (0.98 UEF, at parity).

Where Does Noritz NCC199CDV (GQ-C3261WZ-FF US) Rank Against Peer Gas Tankless Units?

Audited against 464 ENERGY STAR Gas Tankless listings, Noritz NCC199CDV (GQ-C3261WZ-FF US) holds #1 of 464 (top 7.1%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandNoritz23 certified listingsENERGY STAR PD 3629794
Model NumberNCC199CDV (GQ-C3261WZ-FF US)Draw pattern: High-UsageNCC199CDV (GQ-C3261WZ-FF US)
Uniform Energy Factor (UEF)0.98+0.03 UEF vs. 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency98%At 98.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)26.1" H x 18.1" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.1" D)Doorway & ceiling check
Electrical Circuit Requirements0.9 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-09-30Certified 2024-09-30Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Noritz Units?

No open CPSC recall alerts appeared for Noritz as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Gas Tankless Models Compare Closest to NCC199CDV (GQ-C3261WZ-FF US)?

Compare five nearby ENERGY STAR Gas Tankless options matched closely to Noritz NCC199CDV (GQ-C3261WZ-FF US)'s gallon capacity and 0.98 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Bradford White RTGR150N1 Gas Tankless — — 0.98 (at parity) —
JUNSKY, CAMPLUX, GASLAND, ThermoMate RP*199iB Gas Tankless — — 0.98 (at parity) —
Kiturami KGWH-150JFN Gas Tankless — — 0.98 (at parity) —
Laars LT150NRX1 Gas Tankless — — 0.98 (at parity) —
Bradford White RTGR150X1 Gas Tankless — — 0.98 (at parity) —

What Installation Caveats Apply Before Buying Noritz NCC199CDV (GQ-C3261WZ-FF US)?

Even high-UEF units like Noritz NCC199CDV (GQ-C3261WZ-FF US) (0.98 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Converting a 40K tank to Noritz NCC199CDV (GQ-C3261WZ-FF US) often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Noritz NCC199CDV (GQ-C3261WZ-FF US)'s heat exchanger.
  • Condensing Noritz NCC199CDV (GQ-C3261WZ-FF US) requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Noritz NCC199CDV (GQ-C3261WZ-FF US) delivers continuous 0.98 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Common Homeowner Questions for Noritz NCC199CDV (GQ-C3261WZ-FF US)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Noritz NCC199CDV (GQ-C3261WZ-FF US) eligible for continued manufacture past May 6, 2029?

At 0.98 UEF, Noritz NCC199CDV (GQ-C3261WZ-FF US) achieves Pass: +0.07 / +7.7% for the 2029 DOE standard and stands #1 of 464 (top 7.1%) against Bradford White RTGR150N1 and JUNSKY, CAMPLUX, GASLAND, ThermoMate RP*199iB.

How tall and wide is Noritz NCC199CDV (GQ-C3261WZ-FF US), and what service clearance is needed?

Physical dimensions for Noritz NCC199CDV (GQ-C3261WZ-FF US) are 26.1 in. height and 18.1 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.1" d)); verify stair turns and drain pan width before delivery.

Will Noritz NCC199CDV (GQ-C3261WZ-FF US) require upgrading household electrical panels or gas piping?

Check Natural Gas, Propane piping and venting for Noritz NCC199CDV (GQ-C3261WZ-FF US) (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.

Is Noritz NCC199CDV (GQ-C3261WZ-FF US) economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for Noritz NCC199CDV (GQ-C3261WZ-FF US) (Natural Gas, Propane, 0.98 UEF) hinge on household gallon demand and local gas utility tariffs compared with Bradford White RTGR150N1.

Which installation bottlenecks limit Noritz NCC199CDV (GQ-C3261WZ-FF US)?

Without 3/4 in.–1 in. IFGC gas sizing and Category IV PVC exhaust routing, Noritz NCC199CDV (GQ-C3261WZ-FF US) requires added mechanical rework over standard tank replacements.

How does Noritz NCC199CDV (GQ-C3261WZ-FF US) handle simultaneous showers and laundry?

Noritz NCC199CDV (GQ-C3261WZ-FF US) supplies endless hot water within its maximum BTU/flow curve—check cold-climate winter groundwater temperatures before running 3+ fixtures at once.

How long is the warranty on Noritz NCC199CDV (GQ-C3261WZ-FF US) and how do you decode its serial?

CPSC records show 0 active plumbing recalls for Noritz as of 2026-11-23. Confirm install proof and serial manufacture year on Noritz NCC199CDV (GQ-C3261WZ-FF US) before calling service.

How do 2026 post-OBBBA rebates affect buying Noritz NCC199CDV (GQ-C3261WZ-FF US)?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas Tankless is Bradford White RTGR150N1 (0.98 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks