Skip to main content
ENERGY STAR water heater model · PD 2408764

RELIANCE WATER HEATERS 6-40-*RPCS 1** Water Heater Specifications (0.9 UEF)

In the 71-unit Gas Storage class, RELIANCE WATER HEATERS 6-40-*RPCS 1** (Natural Gas) achieves a certified 0.9 UEF rating across its 38-gallon nominal tank, 86 gal First Hour Rating (rank #1 of 71, PD 2408764) and verifies as Pass: +0.32 / +55.2% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is A. O. Smith GC6-PS4050*V 1** (0.9 UEF).

Uniform Energy Factor
0.9 UEF
Cohort UEF Rank
#1 of 71
First Hour Rating
86 gal
Storage Volume
38 gal
Fuel / Type
Natural Gas / Gas Storage
DOE 2029 Rule Status
Pass: +0.32 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas Storage UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas Storage, marking RELIANCE WATER HEATERS 6-40-*RPCS 1** at 0.9 UEF.119510.86 UEF0.90 UEFMedian 0.902029 min 0.58RELIANCE WATER HEATERS 6-40-*RPCS 1**: 0.90
Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS 6-40-*RPCS 1** relative to the cohort median.
Efficiency comparison & rule summary

RELIANCE WATER HEATERS 6-40-*RPCS 1** records 0.9 UEF efficiency, putting it #1 of 71 among 71 Gas Storage peers.

Reliance water heaters 6-40-*rpcs 1** stores 38 gal nominal; 86 gal first hour rating (-9 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).

Competing options beside RELIANCE WATER HEATERS 6-40-*RPCS 1** (0.9 UEF) are A. O. Smith GC6-PS4050*V 1** (0.9 UEF, at parity) and American PCG62-40S50L 1** (0.9 UEF, at parity).

What Physical and Thermal Ratings Define RELIANCE WATER HEATERS 6-40-*RPCS 1**?

Positioning at #1 of 71 out of 71 Gas Storage peers, RELIANCE WATER HEATERS 6-40-*RPCS 1** pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRELIANCE WATER HEATERS71 certified listingsENERGY STAR PD 2408764
Model Number6-40-*RPCS 1**Draw pattern: High-Usage6-40-*RPCS 1**
Uniform Energy Factor (UEF)0.9At 0.90 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)86 gal-9 gal vs. 95 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency91%-3.0 pts vs. 94.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)44.7" H x 22" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D)Doorway & ceiling check
Electrical Circuit Requirements2 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any RELIANCE WATER HEATERS Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 3 brand notices under RELIANCE WATER HEATERS; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

What Are 5 Direct Alternatives to RELIANCE WATER HEATERS 6-40-*RPCS 1**?

Homeowners cross-shopping RELIANCE WATER HEATERS 6-40-*RPCS 1** frequently review these five Gas Storage models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith GC6-PS4050*V 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
American PCG62-40S50L 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
Envirosense Enercare ENV-40N-ENER 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
Envirosense Reliance Home Comfort ENV-40N-RHC 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
A. O. Smith GC9-PS4050NV 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —

Which Home Setups Are NOT a Fit for RELIANCE WATER HEATERS 6-40-*RPCS 1**?

Comparing RELIANCE WATER HEATERS 6-40-*RPCS 1** against A. O. Smith GC6-PS4050*V 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • RELIANCE WATER HEATERS 6-40-*RPCS 1** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect RELIANCE WATER HEATERS 6-40-*RPCS 1**'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 86 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for RELIANCE WATER HEATERS 6-40-*RPCS 1** Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like A. O. Smith GC6-PS4050*V 1**.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Sizing, Efficiency & Recall Answers for RELIANCE WATER HEATERS 6-40-*RPCS 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does RELIANCE WATER HEATERS 6-40-*RPCS 1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; RELIANCE WATER HEATERS 6-40-*RPCS 1** logs 0.9 UEF (Pass: +0.32 / +55.2%) within the 71-unit Gas Storage group.

What physical clearance dimensions apply when installing RELIANCE WATER HEATERS 6-40-*RPCS 1**?

With a 44.7 in. height and 22 in. diameter, RELIANCE WATER HEATERS 6-40-*RPCS 1** fits spaces matching: fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d), plus 6–12 in. above for plumbing shutoffs.

What 240V circuit or IFGC fuel line capacity fits RELIANCE WATER HEATERS 6-40-*RPCS 1**?

RELIANCE WATER HEATERS 6-40-*RPCS 1** utilizes Natural Gas combustion (120V AC ignition/fan + gas piping check). Confirm static/dynamic manifold pressure and 120V GFCI outlet availability before swapping out an older storage tank.

How do state electricity prices change annual costs for RELIANCE WATER HEATERS 6-40-*RPCS 1**?

RELIANCE WATER HEATERS 6-40-*RPCS 1** operates on Natural Gas (0.9 UEF); check regional therm costs and hot-water recirculation schedules since tankless standby electricity stays minimal.

What homeowner setups should avoid choosing RELIANCE WATER HEATERS 6-40-*RPCS 1**?

Homes with >10.5 GPG Very Hard well water without regular 6-month sediment draining will shorten the tank life of RELIANCE WATER HEATERS 6-40-*RPCS 1** (Pass: +0.32 / +55.2%).

Is RELIANCE WATER HEATERS 6-40-*RPCS 1** sized adequately for a 2-to-4-person household?

ENERGY STAR certifies RELIANCE WATER HEATERS 6-40-*RPCS 1** at 86 gal First Hour Rating (-9 gal vs. 95 gal median); match that hourly reserve against simultaneous 2.0 GPM showerheads.

Does RELIANCE WATER HEATERS have active CPSC SaferProducts notices affecting 6-40-*RPCS 1**?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches RELIANCE WATER HEATERS 6-40-*RPCS 1** (0.9 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for RELIANCE WATER HEATERS 6-40-*RPCS 1**. Closest peer in Gas Storage is A. O. Smith GC6-PS4050*V 1** (0.9 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks