Skip to main content
ENERGY STAR water heater model · PD 4015957

RELIANCE WATER HEATERS RTM-180M-N 1** Water Heater Specifications (0.95 UEF)

Engineered as a Natural Gas Gas Tankless unit, RELIANCE WATER HEATERS RTM-180M-N 1** achieves a certified 0.95 UEF rating and ranks #159 of 464 in its 464-model cohort (PD 4015957), recording Pass: +0.04 / +4.4% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking RELIANCE WATER HEATERS RTM-180M-N 1** at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91RELIANCE WATER HEATERS RTM-180M-N 1**: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows RELIANCE WATER HEATERS RTM-180M-N 1** relative to the cohort median.
Efficiency comparison & rule summary

Within the 464-unit Gas Tankless cohort, RELIANCE WATER HEATERS RTM-180M-N 1** logs 0.95 UEF and ranks #159 of 464.

RELIANCE WATER HEATERS RTM-180M-N 1** delivers +0.04 UEF (+4.4%) margin above the 0.91 UEF Natural Gas tankless mandate; thermal recovery tests at 96% (-2.0 pts vs. 98.0% median).

Cross-shopping RELIANCE WATER HEATERS RTM-180M-N 1** (0.95 UEF)? Check A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity).

How Do RELIANCE WATER HEATERS RTM-180M-N 1** Specs Compare to Gas Tankless Medians?

RELIANCE WATER HEATERS RTM-180M-N 1** places #159 of 464 across 464 certified Gas Tankless configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRELIANCE WATER HEATERS71 certified listingsENERGY STAR PD 4015957
Model NumberRTM-180M-N 1**Draw pattern: High-UsageRTM-180M-N 1**
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency96%-2.0 pts vs. 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2025-04-21Certified 2025-04-21Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for RELIANCE WATER HEATERS Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 3 brand-level recall notices associated with RELIANCE WATER HEATERS; match your serial plate before repair. See Serial Number Lookup.

3 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which Certified Water Heaters Match RTM-180M-N 1** Most Closely?

These 5 competing Gas Tankless units sit nearest to RELIANCE WATER HEATERS RTM-180M-N 1** by storage capacity and 0.95 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

Which Home Setups Are NOT a Fit for RELIANCE WATER HEATERS RTM-180M-N 1**?

Comparing RELIANCE WATER HEATERS RTM-180M-N 1** against A. O. Smith ACT-199O-N 1** requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Converting a 40K tank to RELIANCE WATER HEATERS RTM-180M-N 1** often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect RELIANCE WATER HEATERS RTM-180M-N 1**'s heat exchanger.
  • Condensing RELIANCE WATER HEATERS RTM-180M-N 1** requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — RELIANCE WATER HEATERS RTM-180M-N 1** delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

What Are the Key Questions About RELIANCE WATER HEATERS RTM-180M-N 1**?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does RELIANCE WATER HEATERS RTM-180M-N 1** score under 10 CFR 430.32 May 2029 water heater minimums?

Federal 10 CFR 430.32 rules set the May 6, 2029 manufacturing baseline; RELIANCE WATER HEATERS RTM-180M-N 1** logs 0.95 UEF (Pass: +0.04 / +4.4%) within the 464-unit Gas Tankless group.

What physical clearance dimensions apply when installing RELIANCE WATER HEATERS RTM-180M-N 1**?

Because RELIANCE WATER HEATERS RTM-180M-N 1** is a gas tankless unit (wall-hung / compact envelope), check wall-stud backing, condensate neutralizer routing, and outdoor vent clearances first.

What 240V circuit or IFGC fuel line capacity fits RELIANCE WATER HEATERS RTM-180M-N 1**?

RELIANCE WATER HEATERS RTM-180M-N 1** utilizes Natural Gas combustion (120V AC ignition/fan + gas piping check). Confirm static/dynamic manifold pressure and 120V GFCI outlet availability before swapping out an older storage tank.

How do state electricity prices change annual costs for RELIANCE WATER HEATERS RTM-180M-N 1**?

RELIANCE WATER HEATERS RTM-180M-N 1** operates on Natural Gas (0.95 UEF); check regional therm costs and hot-water recirculation schedules since tankless standby electricity stays minimal.

What homeowner setups should avoid choosing RELIANCE WATER HEATERS RTM-180M-N 1**?

Northern homes with 40–45 °F winter groundwater see reduced simultaneous GPM output from RELIANCE WATER HEATERS RTM-180M-N 1**, while hard water >7.0 GPG demands annual vinegar flushing.

Is RELIANCE WATER HEATERS RTM-180M-N 1** sized adequately for a 2-to-4-person household?

Instead of First Hour Rating, RELIANCE WATER HEATERS RTM-180M-N 1** heats water continuously; two concurrent 2.0 GPM showers and a faucet require ~5.5 GPM at a 70 °F temperature rise.

Does RELIANCE WATER HEATERS have active CPSC SaferProducts notices affecting RTM-180M-N 1**?

CPSC SaferProducts records show 3 brand-level recall notices mentioning RELIANCE WATER HEATERS as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

Which competing water heater matches RELIANCE WATER HEATERS RTM-180M-N 1** (0.95 UEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for RELIANCE WATER HEATERS RTM-180M-N 1**. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks