ENERGY STAR water heater model · PD 3462974

Rheem CRTGH-SR11I Water Heater Specifications (0.96 UEF)

In the 464-unit Gas Tankless class, Rheem CRTGH-SR11I (Natural Gas, Propane) achieves a certified 0.96 UEF rating (rank #39 of 464, PD 3462974) and verifies as Pass: +0.05 / +5.5% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is Bradford White RTGR199N1** (0.96 UEF).

Uniform Energy Factor
0.96 UEF
Cohort UEF Rank
#39 of 464 (top 34.1%)
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas, Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.05 / +5.5%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Rheem CRTGH-SR11I at 0.96 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Rheem CRTGH-SR11I: 0.96
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Rheem CRTGH-SR11I relative to the cohort median.
Efficiency comparison & rule summary

Rheem CRTGH-SR11I records 0.96 UEF efficiency, putting it #39 of 464 among 464 Gas Tankless peers.

DOE 2029 compliance check: Rheem CRTGH-SR11I sits +0.05 UEF (+5.5%) above 0.91 UEF; thermal recovery tests at 98% (At 98.0% median).

Competing options beside Rheem CRTGH-SR11I (0.96 UEF) are Bradford White RTGR199N1** (0.96 UEF, at parity) and Friedrich FDTGH-S10I (0.96 UEF, at parity).

How Do Rheem CRTGH-SR11I Specs Compare to Gas Tankless Medians?

Rheem CRTGH-SR11I places #39 of 464 (top 34.1%) across 464 certified Gas Tankless configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3462974
Model NumberCRTGH-SR11IDraw pattern: High-UsageCRTGH-SR11I
Uniform Energy Factor (UEF)0.96+0.01 UEF vs. 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency98%At 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements2 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-04-26Certified 2024-04-26Markets: Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Rheem Water Heaters?

Our 2026-11-23 CPSC SaferProducts query surfaced 4 brand-level recall notices associated with Rheem; match your serial plate before repair. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Certified Water Heaters Match CRTGH-SR11I Most Closely?

These 5 competing Gas Tankless units sit nearest to Rheem CRTGH-SR11I by storage capacity and 0.96 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Bradford White RTGR199N1** Gas Tankless — — 0.96 (at parity) —
Friedrich FDTGH-S10I Gas Tankless — — 0.96 (at parity) —
Kepler JSG48-29PCH/180K Gas Tankless — — 0.96 (at parity) —
Kings Peak KNG199ICW Gas Tankless — — 0.96 (at parity) —
Bradford White RTGR199X1** Gas Tankless — — 0.96 (at parity) —

What Installation Caveats Apply Before Buying Rheem CRTGH-SR11I?

Even high-UEF units like Rheem CRTGH-SR11I (0.96 UEF) carry physical space, condensate, and fuel-line prerequisites noted below.

Key Limitations & Exclusions

  • Converting a 40K tank to Rheem CRTGH-SR11I often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Rheem CRTGH-SR11I's heat exchanger.
  • Condensing Rheem CRTGH-SR11I requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Rheem CRTGH-SR11I delivers continuous 0.96 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

What Are the Key Questions About Rheem CRTGH-SR11I?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is Rheem CRTGH-SR11I eligible for continued manufacture past May 6, 2029?

At 0.96 UEF, Rheem CRTGH-SR11I achieves Pass: +0.05 / +5.5% for the 2029 DOE standard and stands #39 of 464 (top 34.1%) against Bradford White RTGR199N1** and Friedrich FDTGH-S10I.

How tall and wide is Rheem CRTGH-SR11I, and what service clearance is needed?

Rheem CRTGH-SR11I saves floor space via its gas tankless layout (wall-hung / compact envelope); inspect service-valve swing clearance below the bottom manifold.

Will Rheem CRTGH-SR11I require upgrading household electrical panels or gas piping?

Check Natural Gas, Propane piping and venting for Rheem CRTGH-SR11I (120V AC ignition/fan + gas piping check); undersized 1/2 in. gas branches cause peak-demand ignition lockouts on high-input burners.

Is Rheem CRTGH-SR11I economical to operate at 18.16 cents/kWh US electric rates?

Fuel bills for Rheem CRTGH-SR11I (Natural Gas, Propane, 0.96 UEF) hinge on household gallon demand and local gas utility tariffs compared with Bradford White RTGR199N1**.

Which installation bottlenecks limit Rheem CRTGH-SR11I?

Without 3/4 in.–1 in. IFGC gas sizing and Category IV PVC exhaust routing, Rheem CRTGH-SR11I requires added mechanical rework over standard tank replacements.

How does Rheem CRTGH-SR11I handle simultaneous showers and laundry?

Rheem CRTGH-SR11I supplies endless hot water within its maximum BTU/flow curve—check cold-climate winter groundwater temperatures before running 3+ fixtures at once.

How long is the warranty on Rheem CRTGH-SR11I and how do you decode its serial?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

How do 2026 post-OBBBA rebates affect buying Rheem CRTGH-SR11I?

Check state energy office HEAR portals and utility rebates in 2026 since federal 25C ended Dec 31, 2025. Closest peer in Gas Tankless is Bradford White RTGR199N1** (0.96 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks