Skip to main content
ENERGY STAR water heater model · PD 3462939

Rheem RECTGH-SR10IP Water Heater Specifications (0.96 UEF)

In the 464-unit Gas Tankless class, Rheem RECTGH-SR10IP (Propane) achieves a certified 0.96 UEF rating (rank #39 of 464, PD 3462939) and verifies as Pass: +0.05 / +5.5% for 2029 DOE floors. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is Bradford White RTGR199N1** (0.96 UEF).

Uniform Energy Factor
0.96 UEF
Cohort UEF Rank
#39 of 464 (top 34.1%)
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.05 / +5.5%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Rheem RECTGH-SR10IP at 0.96 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Rheem RECTGH-SR10IP: 0.96
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Rheem RECTGH-SR10IP relative to the cohort median.
Efficiency comparison & rule summary

Rheem RECTGH-SR10IP records 0.96 UEF efficiency, putting it #39 of 464 among 464 Gas Tankless peers.

DOE 2029 compliance check: Rheem RECTGH-SR10IP sits +0.05 UEF (+5.5%) above 0.91 UEF; thermal recovery tests at 98% (At 98.0% median).

Competing options beside Rheem RECTGH-SR10IP (0.96 UEF) are Bradford White RTGR199N1** (0.96 UEF, at parity) and Friedrich FDTGH-S10I (0.96 UEF, at parity).

Where Does Rheem RECTGH-SR10IP Rank Against Peer Gas Tankless Units?

Audited against 464 ENERGY STAR Gas Tankless listings, Rheem RECTGH-SR10IP holds #39 of 464 (top 34.1%); inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRheem236 certified listingsENERGY STAR PD 3462939
Model NumberRECTGH-SR10IPDraw pattern: High-UsageRECTGH-SR10IP
Uniform Energy Factor (UEF)0.96+0.01 UEF vs. 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency98%At 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements2 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-04-26Certified 2024-04-26Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Rheem Units?

Checking 2026-11-23 SaferProducts data shows 4 notices mentioning Rheem; always cross-reference affected serial prefixes before ordering components. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #16177 (2016-05-26): Rheem Recalls to Repair Water Heaters Due to Fire and Burn Hazards; Sold Exclusively at Home Depot (CPSC Notice)
  • Recall #07108 (2007-02-21): Tankless Water Heaters Recalled for Repair Due to Carbon Monoxide Poisoning Hazard (CPSC Notice)
  • Recall #05274 (2005-09-16): CPSC, Robertshaw Controls Co. Announce Recall of Gas Control Valves on Water Heaters (CPSC Notice)
  • Recall #80042 (1980-12-04): LP Gas Water Heaters Repaired by White-Rodgers (CPSC Notice)

Which Competing Gas Tankless Models Compare Closest to RECTGH-SR10IP?

Compare five nearby ENERGY STAR Gas Tankless options matched closely to Rheem RECTGH-SR10IP's gallon capacity and 0.96 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Bradford White RTGR199N1** Gas Tankless — — 0.96 (at parity) —
Friedrich FDTGH-S10I Gas Tankless — — 0.96 (at parity) —
Kepler JSG48-29PCH/180K Gas Tankless — — 0.96 (at parity) —
Kings Peak KNG199ICW Gas Tankless — — 0.96 (at parity) —
Bradford White RTGR199X1** Gas Tankless — — 0.96 (at parity) —

Who Is Rheem RECTGH-SR10IP Best For — and When Should You Pick Bradford White RTGR199N1**?

Evaluate whether Rheem RECTGH-SR10IP's Gas Tankless architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Converting a 40K tank to Rheem RECTGH-SR10IP often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Rheem RECTGH-SR10IP's heat exchanger.
  • Condensing Rheem RECTGH-SR10IP requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Rheem RECTGH-SR10IP delivers continuous 0.96 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Common Homeowner Questions for Rheem RECTGH-SR10IP

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Rheem RECTGH-SR10IP (0.96 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Rheem RECTGH-SR10IP records 0.96 UEF (Pass: +0.05 / +5.5%), placing #39 of 464 (top 34.1%) out of 464 certified Gas Tankless configurations.

Does Rheem RECTGH-SR10IP fit inside a tight hallway closet or low-headroom utility room?

Designed as a compact gas tankless platform (wall-hung / compact envelope), Rheem RECTGH-SR10IP still needs code-compliant flue separation from windows and gas meters.

What power supply or fuel line specs govern Rheem RECTGH-SR10IP?

Installing Rheem RECTGH-SR10IP on Propane involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

What annual utility bill should homeowners budget for Rheem RECTGH-SR10IP?

Rated 0.96 UEF on Propane, Rheem RECTGH-SR10IP carries no whole-house kWh heating draw; confirm annual therm usage against 464 Gas Tankless models.

What are the main drawbacks of Rheem RECTGH-SR10IP (0.96 UEF)?

Homeowners unwilling to perform 12-month scale flushes in >=7.0 GPG water or upgrade 1/2 in. gas piping should weigh Bradford White RTGR199N1** or hybrid alternatives.

What hot-water delivery rating governs Rheem RECTGH-SR10IP?

On-demand Gas Tankless sizing for Rheem RECTGH-SR10IP depends on winter inlet water temp (typically 45–65 °F) heated to a 120 °F anti-scald setpoint.

Where do homeowners screen Rheem RECTGH-SR10IP for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning Rheem as of 2026-11-23, including #16177 (2016-05-26). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to Rheem RECTGH-SR10IP in the Gas Tankless class?

Closest peer in Gas Tankless is Bradford White RTGR199N1** (0.96 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks