Richmond 12GUH50-50F* Water Heater Specifications (0.88 UEF)

Certified at 0.88 UEF across its 50-gallon nominal tank, 95 gal First Hour Rating, Richmond 12GUH50-50F* (Gas Storage, Natural Gas, Propane) places #52 of 71 out of 71 ENERGY STAR models (PD 2408631). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.30 / +51.7%. Annual fuel cost depends on regional gas/fuel tariffs and verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d). Closest certified alternative is Friedrich 12PROG 50-50P FD HE EC3 (0.88 UEF).

Uniform Energy Factor
0.88 UEF
Cohort UEF Rank
#52 of 71
First Hour Rating
95 gal
Storage Volume
50 gal
Fuel / Type
Natural Gas, Propane / Gas Storage
DOE 2029 Rule Status
Pass: +0.30 / +51.7%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas Storage UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas Storage, marking Richmond 12GUH50-50F* at 0.88 UEF.119510.86 UEF0.90 UEFMedian 0.902029 min 0.58Richmond 12GUH50-50F*: 0.88
Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows Richmond 12GUH50-50F* relative to the cohort median.
Efficiency comparison & rule summary

Tested at 0.88 UEF, Richmond 12GUH50-50F* places #52 of 71 across 71 certified Gas Storage configurations (-0.02 UEF vs. 0.90 UEF median).

Richmond 12guh50-50f* stores 50 gal nominal; 95 gal first hour rating (at 95 gal median); verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d).

Closest alternatives to Richmond 12GUH50-50F* include Friedrich 12PROG 50-50P FD HE EC3 (0.88 UEF, at parity) alongside Rheem ECE G50-50U CN HE* (0.88 UEF, at parity).

How Complete Are the Certified Metrics for Richmond 12GUH50-50F*?

Standing at #52 of 71 among 71 certified Gas Storage heaters, Richmond 12GUH50-50F* brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 2408631
Model Number12GUH50-50F*Draw pattern: High-Usage12GUH50-50F*
Uniform Energy Factor (UEF)0.88-0.02 UEF vs. 0.90 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)95 galAt 95 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency94%At 94.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)65.5" H x 21.8" DVerify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" D)Doorway & ceiling check
Electrical Circuit Requirements7 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-11-04Certified 2024-11-04Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Richmond Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Richmond in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to 12GUH50-50F*?

Ordered by minimal capacity and UEF spread relative to Richmond 12GUH50-50F*, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Friedrich 12PROG 50-50P FD HE EC3 Gas Storage 50 gal 95 gal 0.88 (at parity) —
Rheem ECE G50-50U CN HE* Gas Storage 50 gal 95 gal 0.88 (at parity) —
Ruud PRO+G50-50P RU HE EC1 Gas Storage 50 gal 95 gal 0.88 (at parity) —
A. O. Smith HCCC-50T 1** Gas Storage 49 gal 98 gal 0.86 (-0.02) —
Friedrich 12PROG 50-50U FD HE EC3 Gas Storage 50 gal 95 gal 0.88 (at parity) —

When Should Homeowners Skip Richmond 12GUH50-50F* (Gas Storage)?

Check Richmond 12GUH50-50F*'s mechanical constraints—including utility space, Natural Gas, Propane capacity, and Pass: +0.30 / +51.7% status—against typical residential installations.

Key Limitations & Exclusions

  • Richmond 12GUH50-50F* logs 0.88 UEF (Pass: +0.30 / +51.7%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect Richmond 12GUH50-50F*'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 95 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for Richmond 12GUH50-50F* Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Friedrich 12PROG 50-50P FD HE EC3.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Practical Specs & Code Questions for Richmond 12GUH50-50F*

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Richmond 12GUH50-50F* stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.88 UEF, Richmond 12GUH50-50F* shows Pass: +0.30 / +51.7% relative to May 6, 2029 federal DOE limits while placing #52 of 71 among 71 Gas Storage peers like Friedrich 12PROG 50-50P FD HE EC3.

Will Richmond 12GUH50-50F* fit through a standard utility door and 72-inch basement ceiling?

Measuring 65.5 in. tall by 21.8 in. diameter, Richmond 12GUH50-50F* notes: verify 72 in. vertical headroom; clears 28 in. utility doorway (21.8" d). Reserve space above the jacket for T&P piping and anode removal.

Do existing utility hookups support Richmond 12GUH50-50F* during replacement?

Fueled by Natural Gas, Propane, Richmond 12GUH50-50F* specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

What is the estimated 10-year operating spend for Richmond 12GUH50-50F*?

Because Richmond 12GUH50-50F* burns Natural Gas, Propane at 0.88 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 71 peers.

When is Richmond 12GUH50-50F* a poor fit for a residential replacement?

Avoid Richmond 12GUH50-50F* if household peak demand surpasses 95 gal per hour or if state DOE HEAR incentives require >=2.30 UEF heat-pump equipment.

What First Hour Rating or flow capacity does Richmond 12GUH50-50F* deliver?

With 95 gal FHR (At 95 gal median), Richmond 12GUH50-50F* fits larger 3–5 person homes cleanly.

How do you verify manufacturing age and recall status on Richmond 12GUH50-50F*?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Richmond; verify exact manufacturing week for Richmond 12GUH50-50F* using the Serial Number Lookup tool.

Does Richmond 12GUH50-50F* qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Richmond 12GUH50-50F*. Closest peer in Gas Storage is Friedrich 12PROG 50-50P FD HE EC3 (0.88 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks