Skip to main content
ENERGY STAR water heater model · PD 3462970

Richmond RMTGHSR11IP Water Heater Specifications (0.96 UEF)

The Richmond RMTGHSR11IP (Gas Tankless, Propane) achieves a certified 0.96 UEF rating, ranking #39 of 464 among 464 ENERGY STAR Gas Tankless models (PD 3462970). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.05 / +5.5%. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is Bradford White RTGR199N1** (0.96 UEF).

Uniform Energy Factor
0.96 UEF
Cohort UEF Rank
#39 of 464 (top 34.1%)
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.05 / +5.5%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Richmond RMTGHSR11IP at 0.96 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Richmond RMTGHSR11IP: 0.96
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Richmond RMTGHSR11IP relative to the cohort median.
Efficiency comparison & rule summary

Richmond RMTGHSR11IP (0.96 UEF) ranks #39 of 464 Gas Tankless models — 120-way tie; top 34.1%, more efficient than 65.9% of Gas Tankless models, +0.01 UEF above the 0.95 UEF median.

Richmond RMTGHSR11IP (Propane tankless) clears the May 6, 2029 0.91 UEF threshold by +0.05 UEF (+5.5%); thermal recovery tests at 98% (At 98.0% median).

Peer comparison: Richmond RMTGHSR11IP (0.96 UEF) compares closely with Bradford White RTGR199N1** (0.96 UEF, at parity) and Friedrich FDTGH-S10I (0.96 UEF, at parity).

How Complete Are the Certified Metrics for Richmond RMTGHSR11IP?

Standing at #39 of 464 (top 34.1%) among 464 certified Gas Tankless heaters, Richmond RMTGHSR11IP brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandRichmond80 certified listingsENERGY STAR PD 3462970
Model NumberRMTGHSR11IPDraw pattern: High-UsageRMTGHSR11IP
Uniform Energy Factor (UEF)0.96+0.01 UEF vs. 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency98%At 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements2 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-04-26Certified 2024-04-26Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Richmond Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Richmond in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to RMTGHSR11IP?

Ordered by minimal capacity and UEF spread relative to Richmond RMTGHSR11IP, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Bradford White RTGR199N1** Gas Tankless — — 0.96 (at parity) —
Friedrich FDTGH-S10I Gas Tankless — — 0.96 (at parity) —
Kepler JSG48-29PCH/180K Gas Tankless — — 0.96 (at parity) —
Kings Peak KNG199ICW Gas Tankless — — 0.96 (at parity) —
Bradford White RTGR199X1** Gas Tankless — — 0.96 (at parity) —

What Are the Limitations of Richmond RMTGHSR11IP and Who Should Not Install It?

Before ordering Richmond RMTGHSR11IP (Gas Tankless, 0.96 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Converting a 40K tank to Richmond RMTGHSR11IP often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Richmond RMTGHSR11IP's heat exchanger.
  • Condensing Richmond RMTGHSR11IP requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Richmond RMTGHSR11IP delivers continuous 0.96 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Practical Specs & Code Questions for Richmond RMTGHSR11IP

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Richmond RMTGHSR11IP pass the May 6, 2029 federal DOE efficiency rule?

Richmond RMTGHSR11IP carries a verified 0.96 UEF rating (Pass: +0.05 / +5.5%), ranking #39 of 464 (top 34.1%) across 464 ENERGY STAR Gas Tankless models under 10 CFR 430.32.

What doorway width and ceiling height does Richmond RMTGHSR11IP need?

Richmond RMTGHSR11IP mounts as a gas tankless without a bulky floor tank (wall-hung / compact envelope). Verify vent termination distances and combustion air clearances per IPC or UPC.

What gas pipe size or electrical breaker does Richmond RMTGHSR11IP require?

Richmond RMTGHSR11IP runs on Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

How much electricity or energy does Richmond RMTGHSR11IP cost per year to run?

ENERGY STAR rates Richmond RMTGHSR11IP as a Propane heater (0.96 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas Tankless draw.

Who should NOT install Richmond RMTGHSR11IP, and what are its limits?

Richmond RMTGHSR11IP (0.96 UEF) is rarely a drop-in swap over a 40K tank if existing 1/2 in. gas pipe cannot supply 199,000 BTU/h or hardness exceeds 7.0 GPG without descaling.

How many bathrooms or people can Richmond RMTGHSR11IP serve at peak demand?

Richmond RMTGHSR11IP provides continuous Gas Tankless delivery rather than a fixed storage FHR; size GPM flow against winter incoming groundwater temperature and 2.0 GPM showers.

Are there CPSC safety recalls or serial checks for Richmond RMTGHSR11IP?

No active CPSC recalls matched Richmond as of 2026-11-23. Always decode the serial tag on Richmond RMTGHSR11IP because OEM tank/exchanger warranties span 6–12 years.

What 2026 rebates apply to Richmond RMTGHSR11IP, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas Tankless is Bradford White RTGR199N1** (0.96 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks