Skip to main content
ENERGY STAR water heater model · PD 2408763

State GP6-40-*RPCSL 1** Water Heater Specifications (0.9 UEF)

With PD 2408763 certification, State GP6-40-*RPCSL 1** (Gas Storage, Natural Gas) achieves a certified 0.9 UEF rating across its 38-gallon nominal tank, 86 gal First Hour Rating, standing #1 of 71 across 71 peers with Pass: +0.32 / +55.2% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is A. O. Smith GC6-PS4050*V 1** (0.9 UEF).

Uniform Energy Factor
0.9 UEF
Cohort UEF Rank
#1 of 71
First Hour Rating
86 gal
Storage Volume
38 gal
Fuel / Type
Natural Gas / Gas Storage
DOE 2029 Rule Status
Pass: +0.32 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas Storage UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas Storage, marking State GP6-40-*RPCSL 1** at 0.9 UEF.119510.86 UEF0.90 UEFMedian 0.902029 min 0.58State GP6-40-*RPCSL 1**: 0.90
Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows State GP6-40-*RPCSL 1** relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places State GP6-40-*RPCSL 1** at 0.9 UEF (#1 of 71; At 0.90 UEF median) in Gas Storage.

State gp6-40-*rpcsl 1** stores 38 gal nominal; 86 gal first hour rating (-9 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).

In the Gas Storage tier, A. O. Smith GC6-PS4050*V 1** (0.9 UEF, at parity) and American PCG62-40S50L 1** (0.9 UEF, at parity) bracket State GP6-40-*RPCSL 1**.

How Complete Are the Certified Metrics for State GP6-40-*RPCSL 1**?

Standing at #1 of 71 among 71 certified Gas Storage heaters, State GP6-40-*RPCSL 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 2408763
Model NumberGP6-40-*RPCSL 1**Draw pattern: High-UsageGP6-40-*RPCSL 1**
Uniform Energy Factor (UEF)0.9At 0.90 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)86 gal-9 gal vs. 95 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency91%-3.0 pts vs. 94.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)44.7" H x 22" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D)Doorway & ceiling check
Electrical Circuit Requirements2 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are State Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for State and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which 5 Models Offer Similar Output to GP6-40-*RPCSL 1**?

Ordered by minimal capacity and UEF spread relative to State GP6-40-*RPCSL 1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith GC6-PS4050*V 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
American PCG62-40S50L 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
Envirosense Enercare ENV-40N-ENER 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
Envirosense Reliance Home Comfort ENV-40N-RHC 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
A. O. Smith GC9-PS4050NV 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —

Who Is State GP6-40-*RPCSL 1** Best For — and When Should You Pick A. O. Smith GC6-PS4050*V 1**?

Evaluate whether State GP6-40-*RPCSL 1**'s Gas Storage architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • State GP6-40-*RPCSL 1** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect State GP6-40-*RPCSL 1**'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 86 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for State GP6-40-*RPCSL 1** Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like A. O. Smith GC6-PS4050*V 1**.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Practical Specs & Code Questions for State GP6-40-*RPCSL 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does State GP6-40-*RPCSL 1** (0.9 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, State GP6-40-*RPCSL 1** records 0.9 UEF (Pass: +0.32 / +55.2%), placing #1 of 71 out of 71 certified Gas Storage configurations.

Does State GP6-40-*RPCSL 1** fit inside a tight hallway closet or low-headroom utility room?

State GP6-40-*RPCSL 1** requires room for its 44.7 in. vertical shell and 22 in. diameter (fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d)), plus service access for annual sediment draining.

What power supply or fuel line specs govern State GP6-40-*RPCSL 1**?

Installing State GP6-40-*RPCSL 1** on Natural Gas involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

What annual utility bill should homeowners budget for State GP6-40-*RPCSL 1**?

Rated 0.9 UEF on Natural Gas, State GP6-40-*RPCSL 1** carries no whole-house kWh heating draw; confirm annual therm usage against 71 Gas Storage models.

What are the main drawbacks of State GP6-40-*RPCSL 1** (0.9 UEF)?

Buyers expecting endless simultaneous shower flow beyond 86 gal should compare condensing tankless units or larger-capacity tanks.

What hot-water delivery rating governs State GP6-40-*RPCSL 1**?

Rated for 86 gal FHR (-9 gal vs. 95 gal median), State GP6-40-*RPCSL 1** prevents mid-morning cold drops when matched to 55–70+ gal multi-bath household loads.

Where do homeowners screen State GP6-40-*RPCSL 1** for recalls and tank age?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What alternative models sit closest to State GP6-40-*RPCSL 1** in the Gas Storage class?

Closest peer in Gas Storage is A. O. Smith GC6-PS4050*V 1** (0.9 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks