Skip to main content
ENERGY STAR water heater model · PD 3798672

State GP8-40-YRPCSL 1** Water Heater Specifications (0.9 UEF)

Engineered as a Natural Gas, Propane Gas Storage unit, State GP8-40-YRPCSL 1** achieves a certified 0.9 UEF rating across its 38-gallon nominal tank, 86 gal First Hour Rating and ranks #1 of 71 in its 71-model cohort (PD 3798672), recording Pass: +0.32 / +55.2% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Closest certified alternative is A. O. Smith GC6-PS4050*V 1** (0.9 UEF).

Uniform Energy Factor
0.9 UEF
Cohort UEF Rank
#1 of 71
First Hour Rating
86 gal
Storage Volume
38 gal
Fuel / Type
Natural Gas, Propane / Gas Storage
DOE 2029 Rule Status
Pass: +0.32 / +55.2%
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Gas Storage UEF Efficiency Distribution (71 Certified Units)Distribution of certified UEF ratings across 71 units in Gas Storage, marking State GP8-40-YRPCSL 1** at 0.9 UEF.119510.86 UEF0.90 UEFMedian 0.902029 min 0.58State GP8-40-YRPCSL 1**: 0.90
Gas Storage UEF Efficiency Distribution (71 Certified Units). Highlighted pin shows State GP8-40-YRPCSL 1** relative to the cohort median.
Efficiency comparison & rule summary

Within the 71-unit Gas Storage cohort, State GP8-40-YRPCSL 1** logs 0.9 UEF and ranks #1 of 71.

State gp8-40-yrpcsl 1** stores 38 gal nominal; 86 gal first hour rating (-9 gal vs. 95 gal median); fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d).

Cross-shopping State GP8-40-YRPCSL 1** (0.9 UEF)? Check A. O. Smith GC6-PS4050*V 1** (0.9 UEF, at parity) and American PCG62-40S50L 1** (0.9 UEF, at parity).

How Complete Are the Certified Metrics for State GP8-40-YRPCSL 1**?

Standing at #1 of 71 among 71 certified Gas Storage heaters, State GP8-40-YRPCSL 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 71 ENERGY STAR Gas Storage peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandState81 certified listingsENERGY STAR PD 3798672
Model NumberGP8-40-YRPCSL 1**Draw pattern: High-UsageGP8-40-YRPCSL 1**
Uniform Energy Factor (UEF)0.9At 0.90 UEF median10 CFR 430 Test Method
First Hour Rating (FHR)86 gal-9 gal vs. 95 gal median10 CFR 430 Recovery Test
Thermal Recovery Efficiency91%-3.0 pts vs. 94.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)44.7" H x 22" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" D)Doorway & ceiling check
Electrical Circuit Requirements2 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-11-13Certified 2024-11-13Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are State Models Affected by Current CPSC Notices?

Review 4 brand-matched CPSC entries pulled 2026-11-23 for State and confirm your serial tag before scheduling contractor service. See Serial Number Lookup.

4 Brand Recall Notices Found in CPSC Feed — Verify Serial & Model Range
  • Recall #19029 (2018-11-08): A. O. Smith Recalls Ultra-Low NOx Water Heaters Due to Fire Hazard (CPSC Notice)
  • Recall #08241 (2008-04-03): A.O. Smith Recalls Gas Water Heaters Due to Fire and Carbon Monoxide Hazards (CPSC Notice)
  • Recall #06002 (2005-10-06): CPSC, A.O. Smith Announce Recall of Water Heaters (CPSC Notice)
  • Recall #04128 (2004-04-28): CPSC, White-Rodgers Announce Recall of LP and Convertible Gas Water Heater Temperature Controls (CPSC Notice)

Which 5 Models Offer Similar Output to GP8-40-YRPCSL 1**?

Ordered by minimal capacity and UEF spread relative to State GP8-40-YRPCSL 1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith GC6-PS4050*V 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
American PCG62-40S50L 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
Envirosense Enercare ENV-40N-ENER 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
Envirosense Reliance Home Comfort ENV-40N-RHC 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —
A. O. Smith GC9-PS4050NV 1** Gas Storage 38 gal 86 gal 0.9 (at parity) —

What Are the Limitations of State GP8-40-YRPCSL 1** and Who Should Not Install It?

Before ordering State GP8-40-YRPCSL 1** (Gas Storage, 0.9 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • State GP8-40-YRPCSL 1** logs 0.9 UEF (Pass: +0.32 / +55.2%); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect State GP8-40-YRPCSL 1**'s sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 86 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for State GP8-40-YRPCSL 1** Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like A. O. Smith GC6-PS4050*V 1**.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Practical Specs & Code Questions for State GP8-40-YRPCSL 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does State GP8-40-YRPCSL 1** pass the May 6, 2029 federal DOE efficiency rule?

State GP8-40-YRPCSL 1** carries a verified 0.9 UEF rating (Pass: +0.32 / +55.2%), ranking #1 of 71 across 71 ENERGY STAR Gas Storage models under 10 CFR 430.32.

What doorway width and ceiling height does State GP8-40-YRPCSL 1** need?

State GP8-40-YRPCSL 1** stands 44.7 in. high with a 22 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (22" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does State GP8-40-YRPCSL 1** require?

State GP8-40-YRPCSL 1** runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

How much electricity or energy does State GP8-40-YRPCSL 1** cost per year to run?

ENERGY STAR rates State GP8-40-YRPCSL 1** as a Natural Gas, Propane heater (0.9 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas Storage draw.

Who should NOT install State GP8-40-YRPCSL 1**, and what are its limits?

State GP8-40-YRPCSL 1** (0.9 UEF) is not suited for multi-bath marathon draws exceeding its 86 gal capacity or buyers prioritizing May 6, 2029 high-UEF HPWH rebates.

How many bathrooms or people can State GP8-40-YRPCSL 1** serve at peak demand?

State GP8-40-YRPCSL 1** achieves a 86 gal First Hour Rating (-9 gal vs. 95 gal median). Two back-to-back showers plus a dishwasher run typically call for 55–70 gal FHR.

Are there CPSC safety recalls or serial checks for State GP8-40-YRPCSL 1**?

CPSC SaferProducts records show 4 brand-level recall notices mentioning State as of 2026-11-23, including #19029 (2018-11-08). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to State GP8-40-YRPCSL 1**, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas Storage is A. O. Smith GC6-PS4050*V 1** (0.9 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)