Skip to main content
ENERGY STAR water heater model · PD 3722218

stream33 S33-95TWH199P-LP/NG Water Heater Specifications (0.95 UEF)

With PD 3722218 certification, stream33 S33-95TWH199P-LP/NG (Gas Tankless, Natural Gas) achieves a certified 0.95 UEF rating, standing #159 of 464 across 464 peers with Pass: +0.04 / +4.4% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking stream33 S33-95TWH199P-LP/NG at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91stream33 S33-95TWH199P-LP/NG: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows stream33 S33-95TWH199P-LP/NG relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places stream33 S33-95TWH199P-LP/NG at 0.95 UEF (#159 of 464; At 0.95 UEF median) in Gas Tankless.

With Natural Gas condensing combustion, stream33 S33-95TWH199P-LP/NG stands +0.04 UEF (+4.4%) above the 2029 0.91 UEF minimum; thermal recovery tests at 99% (+1.0 pts vs. 98.0% median).

In the Gas Tankless tier, A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity) bracket stream33 S33-95TWH199P-LP/NG.

Where Does stream33 S33-95TWH199P-LP/NG Rank Against Peer Gas Tankless Units?

Audited against 464 ENERGY STAR Gas Tankless listings, stream33 S33-95TWH199P-LP/NG holds #159 of 464; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / Brandstream334 certified listingsENERGY STAR PD 3722218
Model NumberS33-95TWH199P-LP/NGDraw pattern: High-UsageS33-95TWH199P-LP/NG
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency99%+1.0 pts vs. 98.0% medianENERGY STAR Dataset
Electrical Circuit Requirements1.3 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2024-10-30Certified 2024-10-30Markets: United States
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on stream33 Units?

No open CPSC recall alerts appeared for stream33 as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Gas Tankless Models Compare Closest to S33-95TWH199P-LP/NG?

Compare five nearby ENERGY STAR Gas Tankless options matched closely to stream33 S33-95TWH199P-LP/NG's gallon capacity and 0.95 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

When Should Homeowners Skip stream33 S33-95TWH199P-LP/NG (Gas Tankless)?

Check stream33 S33-95TWH199P-LP/NG's mechanical constraints—including utility space, Natural Gas capacity, and Pass: +0.04 / +4.4% status—against typical residential installations.

Key Limitations & Exclusions

  • Converting a 40K tank to stream33 S33-95TWH199P-LP/NG often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect stream33 S33-95TWH199P-LP/NG's heat exchanger.
  • Condensing stream33 S33-95TWH199P-LP/NG requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — stream33 S33-95TWH199P-LP/NG delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Common Homeowner Questions for stream33 S33-95TWH199P-LP/NG

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will stream33 S33-95TWH199P-LP/NG stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.95 UEF, stream33 S33-95TWH199P-LP/NG shows Pass: +0.04 / +4.4% relative to May 6, 2029 federal DOE limits while placing #159 of 464 among 464 Gas Tankless peers like A. O. Smith ACT-199O-N 1**.

Will stream33 S33-95TWH199P-LP/NG fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted gas tankless chassis, stream33 S33-95TWH199P-LP/NG eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

Do existing utility hookups support stream33 S33-95TWH199P-LP/NG during replacement?

Fueled by Natural Gas, stream33 S33-95TWH199P-LP/NG specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

What is the estimated 10-year operating spend for stream33 S33-95TWH199P-LP/NG?

Because stream33 S33-95TWH199P-LP/NG burns Natural Gas at 0.95 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 464 peers.

When is stream33 S33-95TWH199P-LP/NG a poor fit for a residential replacement?

Skip stream33 S33-95TWH199P-LP/NG as a quick swap when long 1/2 in. iron gas lines starve ignition (triggering E003/11 codes) or when Type B metal chimney vents cannot handle condensing PVC.

What First Hour Rating or flow capacity does stream33 S33-95TWH199P-LP/NG deliver?

As an on-demand Gas Tankless model, stream33 S33-95TWH199P-LP/NG has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.

How do you verify manufacturing age and recall status on stream33 S33-95TWH199P-LP/NG?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for stream33; verify exact manufacturing week for stream33 S33-95TWH199P-LP/NG using the Serial Number Lookup tool.

Does stream33 S33-95TWH199P-LP/NG qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for stream33 S33-95TWH199P-LP/NG. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks