Skip to main content
ENERGY STAR water heater model · PD 2408817

Takagi T-H3J-OS-N 1** Water Heater Specifications (0.95 UEF)

Engineered as a Natural Gas Gas Tankless unit, Takagi T-H3J-OS-N 1** achieves a certified 0.95 UEF rating and ranks #159 of 464 in its 464-model cohort (PD 2408817), recording Pass: +0.04 / +4.4% under 2029 DOE rules. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Takagi T-H3J-OS-N 1** at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Takagi T-H3J-OS-N 1**: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Takagi T-H3J-OS-N 1** relative to the cohort median.
Efficiency comparison & rule summary

Within the 464-unit Gas Tankless cohort, Takagi T-H3J-OS-N 1** logs 0.95 UEF and ranks #159 of 464.

Takagi T-H3J-OS-N 1** delivers +0.04 UEF (+4.4%) margin above the 0.91 UEF Natural Gas tankless mandate.

Cross-shopping Takagi T-H3J-OS-N 1** (0.95 UEF)? Check A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity).

How Complete Are the Certified Metrics for Takagi T-H3J-OS-N 1**?

Standing at #159 of 464 among 464 certified Gas Tankless heaters, Takagi T-H3J-OS-N 1** brings measurable deltas in recovery, footprint, and energy efficiency.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandTakagi16 certified listingsENERGY STAR PD 2408817
Model NumberT-H3J-OS-N 1**Draw pattern: High-UsageT-H3J-OS-N 1**
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are Takagi Models Affected by Current CPSC Notices?

Zero brand-level CPSC hazard notices matched Takagi in our 2026-11-23 feed; decode your water heater's serial number below to confirm warranty status. See Serial Number Lookup.

Which 5 Models Offer Similar Output to T-H3J-OS-N 1**?

Ordered by minimal capacity and UEF spread relative to Takagi T-H3J-OS-N 1**, these five certified peers give direct replacement benchmarks.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

When Should Homeowners Skip Takagi T-H3J-OS-N 1** (Gas Tankless)?

Check Takagi T-H3J-OS-N 1**'s mechanical constraints—including utility space, Natural Gas capacity, and Pass: +0.04 / +4.4% status—against typical residential installations.

Key Limitations & Exclusions

  • Converting a 40K tank to Takagi T-H3J-OS-N 1** often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Takagi T-H3J-OS-N 1**'s heat exchanger.
  • Condensing Takagi T-H3J-OS-N 1** requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Takagi T-H3J-OS-N 1** delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Practical Specs & Code Questions for Takagi T-H3J-OS-N 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Takagi T-H3J-OS-N 1** stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.95 UEF, Takagi T-H3J-OS-N 1** shows Pass: +0.04 / +4.4% relative to May 6, 2029 federal DOE limits while placing #159 of 464 among 464 Gas Tankless peers like A. O. Smith ACT-199O-N 1**.

Will Takagi T-H3J-OS-N 1** fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted gas tankless chassis, Takagi T-H3J-OS-N 1** eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

Do existing utility hookups support Takagi T-H3J-OS-N 1** during replacement?

Fueled by Natural Gas, Takagi T-H3J-OS-N 1** specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

What is the estimated 10-year operating spend for Takagi T-H3J-OS-N 1**?

Because Takagi T-H3J-OS-N 1** burns Natural Gas at 0.95 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 464 peers.

When is Takagi T-H3J-OS-N 1** a poor fit for a residential replacement?

Skip Takagi T-H3J-OS-N 1** as a quick swap when long 1/2 in. iron gas lines starve ignition (triggering E003/11 codes) or when Type B metal chimney vents cannot handle condensing PVC.

What First Hour Rating or flow capacity does Takagi T-H3J-OS-N 1** deliver?

As an on-demand Gas Tankless model, Takagi T-H3J-OS-N 1** has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.

How do you verify manufacturing age and recall status on Takagi T-H3J-OS-N 1**?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Takagi; verify exact manufacturing week for Takagi T-H3J-OS-N 1** using the Serial Number Lookup tool.

Does Takagi T-H3J-OS-N 1** qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Takagi T-H3J-OS-N 1**. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks