Skip to main content
ENERGY STAR water heater model · PD 2408801

Takagi T-H3S-DV-N 1** Water Heater Specifications (0.95 UEF)

Certified at 0.95 UEF, Takagi T-H3S-DV-N 1** (Gas Tankless, Natural Gas) places #159 of 464 out of 464 ENERGY STAR models (PD 2408801). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.04 / +4.4%. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Takagi T-H3S-DV-N 1** at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Takagi T-H3S-DV-N 1**: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Takagi T-H3S-DV-N 1** relative to the cohort median.
Efficiency comparison & rule summary

Tested at 0.95 UEF, Takagi T-H3S-DV-N 1** places #159 of 464 across 464 certified Gas Tankless configurations (At 0.95 UEF median).

Operating on Natural Gas, Takagi T-H3S-DV-N 1** beats the 2029 0.91 UEF floor by +0.04 UEF (+4.4%).

Closest alternatives to Takagi T-H3S-DV-N 1** include A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) alongside American GT-240-NEH 1** (0.95 UEF, at parity).

Where Does Takagi T-H3S-DV-N 1** Rank Against Peer Gas Tankless Units?

Audited against 464 ENERGY STAR Gas Tankless listings, Takagi T-H3S-DV-N 1** holds #159 of 464; inspect footprint, circuit load, and efficiency deltas here.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandTakagi16 certified listingsENERGY STAR PD 2408801
Model NumberT-H3S-DV-N 1**Draw pattern: High-UsageT-H3S-DV-N 1**
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Does CPSC Flag Any Safety Notices on Takagi Units?

No open CPSC recall alerts appeared for Takagi as of 2026-11-23; you can still decode exact manufacture month and warranty window below. See Serial Number Lookup.

Which Competing Gas Tankless Models Compare Closest to T-H3S-DV-N 1**?

Compare five nearby ENERGY STAR Gas Tankless options matched closely to Takagi T-H3S-DV-N 1**'s gallon capacity and 0.95 UEF efficiency.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

Who Is Takagi T-H3S-DV-N 1** Best For — and When Should You Pick A. O. Smith ACT-199O-N 1**?

Evaluate whether Takagi T-H3S-DV-N 1**'s Gas Tankless architecture matches your existing mechanical room and local utility tariffs before purchasing.

Key Limitations & Exclusions

  • Converting a 40K tank to Takagi T-H3S-DV-N 1** often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Takagi T-H3S-DV-N 1**'s heat exchanger.
  • Condensing Takagi T-H3S-DV-N 1** requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Takagi T-H3S-DV-N 1** delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Common Homeowner Questions for Takagi T-H3S-DV-N 1**

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Takagi T-H3S-DV-N 1** (0.95 UEF) compare to 2029 federal DOE floors?

Evaluated against May 6, 2029 10 CFR 430.32 thresholds, Takagi T-H3S-DV-N 1** records 0.95 UEF (Pass: +0.04 / +4.4%), placing #159 of 464 out of 464 certified Gas Tankless configurations.

Does Takagi T-H3S-DV-N 1** fit inside a tight hallway closet or low-headroom utility room?

Designed as a compact gas tankless platform (wall-hung / compact envelope), Takagi T-H3S-DV-N 1** still needs code-compliant flue separation from windows and gas meters.

What power supply or fuel line specs govern Takagi T-H3S-DV-N 1**?

Installing Takagi T-H3S-DV-N 1** on Natural Gas involves 120V AC ignition/fan + gas piping check. Verify regulator capacity and dedicated Category IV PVC venting rather than reusing legacy galvanized flues.

What annual utility bill should homeowners budget for Takagi T-H3S-DV-N 1**?

Rated 0.95 UEF on Natural Gas, Takagi T-H3S-DV-N 1** carries no whole-house kWh heating draw; confirm annual therm usage against 464 Gas Tankless models.

What are the main drawbacks of Takagi T-H3S-DV-N 1** (0.95 UEF)?

Homeowners unwilling to perform 12-month scale flushes in >=7.0 GPG water or upgrade 1/2 in. gas piping should weigh A. O. Smith ACT-199O-N 1** or hybrid alternatives.

What hot-water delivery rating governs Takagi T-H3S-DV-N 1**?

On-demand Gas Tankless sizing for Takagi T-H3S-DV-N 1** depends on winter inlet water temp (typically 45–65 °F) heated to a 120 °F anti-scald setpoint.

Where do homeowners screen Takagi T-H3S-DV-N 1** for recalls and tank age?

Verified clean against 2026-11-23 CPSC recall feeds for Takagi; use our browser-only serial decoder to inspect Takagi T-H3S-DV-N 1**'s age and warranty window.

What alternative models sit closest to Takagi T-H3S-DV-N 1** in the Gas Tankless class?

Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF). For 2026 incentives, look to state DOE HEAR grants ($1,750 max on qualifying HPWHs) and local municipal utility credits.

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks