Skip to main content
ENERGY STAR water heater model · PD 2408800

Takagi T-H3S-DV-P 1*1 Water Heater Specifications (0.95 UEF)

The Takagi T-H3S-DV-P 1*1 (Gas Tankless, Propane) achieves a certified 0.95 UEF rating, ranking #159 of 464 among 464 ENERGY STAR Gas Tankless models (PD 2408800). Under the May 6, 2029 DOE 10 CFR 430.32(d)(2) standard, compliance status is Pass: +0.04 / +4.4%. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Takagi T-H3S-DV-P 1*1 at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Takagi T-H3S-DV-P 1*1: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Takagi T-H3S-DV-P 1*1 relative to the cohort median.
Efficiency comparison & rule summary

Takagi T-H3S-DV-P 1*1 (0.95 UEF) ranks #159 of 464 Gas Tankless models — 306-way tie; tied at bottom of cohort, at the 0.95 UEF median.

Takagi T-H3S-DV-P 1*1 (Propane tankless) clears the May 6, 2029 0.91 UEF threshold by +0.04 UEF (+4.4%).

Peer comparison: Takagi T-H3S-DV-P 1*1 (0.95 UEF) compares closely with A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) and American GT-240-NEH 1** (0.95 UEF, at parity).

What Physical and Thermal Ratings Define Takagi T-H3S-DV-P 1*1?

Positioning at #159 of 464 out of 464 Gas Tankless peers, Takagi T-H3S-DV-P 1*1 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandTakagi16 certified listingsENERGY STAR PD 2408800
Model NumberT-H3S-DV-P 1*1Draw pattern: High-UsageT-H3S-DV-P 1*1
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Takagi Series Triggered CPSC Recalls?

SaferProducts screening on 2026-11-23 returned zero recall matches for Takagi; confirm tank age separately using the rating-plate serial pattern. See Serial Number Lookup.

What Are 5 Direct Alternatives to Takagi T-H3S-DV-P 1*1?

Homeowners cross-shopping Takagi T-H3S-DV-P 1*1 frequently review these five Gas Tankless models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

When Should Homeowners Skip Takagi T-H3S-DV-P 1*1 (Gas Tankless)?

Check Takagi T-H3S-DV-P 1*1's mechanical constraints—including utility space, Propane capacity, and Pass: +0.04 / +4.4% status—against typical residential installations.

Key Limitations & Exclusions

  • Converting a 40K tank to Takagi T-H3S-DV-P 1*1 often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Takagi T-H3S-DV-P 1*1's heat exchanger.
  • Condensing Takagi T-H3S-DV-P 1*1 requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Takagi T-H3S-DV-P 1*1 delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Sizing, Efficiency & Recall Answers for Takagi T-H3S-DV-P 1*1

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Takagi T-H3S-DV-P 1*1 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.95 UEF, Takagi T-H3S-DV-P 1*1 shows Pass: +0.04 / +4.4% relative to May 6, 2029 federal DOE limits while placing #159 of 464 among 464 Gas Tankless peers like A. O. Smith ACT-199O-N 1**.

Will Takagi T-H3S-DV-P 1*1 fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted gas tankless chassis, Takagi T-H3S-DV-P 1*1 eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

Do existing utility hookups support Takagi T-H3S-DV-P 1*1 during replacement?

Fueled by Propane, Takagi T-H3S-DV-P 1*1 specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

What is the estimated 10-year operating spend for Takagi T-H3S-DV-P 1*1?

Because Takagi T-H3S-DV-P 1*1 burns Propane at 0.95 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 464 peers.

When is Takagi T-H3S-DV-P 1*1 a poor fit for a residential replacement?

Skip Takagi T-H3S-DV-P 1*1 as a quick swap when long 1/2 in. iron gas lines starve ignition (triggering E003/11 codes) or when Type B metal chimney vents cannot handle condensing PVC.

What First Hour Rating or flow capacity does Takagi T-H3S-DV-P 1*1 deliver?

As an on-demand Gas Tankless model, Takagi T-H3S-DV-P 1*1 has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.

How do you verify manufacturing age and recall status on Takagi T-H3S-DV-P 1*1?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Takagi; verify exact manufacturing week for Takagi T-H3S-DV-P 1*1 using the Serial Number Lookup tool.

Does Takagi T-H3S-DV-P 1*1 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Takagi T-H3S-DV-P 1*1. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks