Skip to main content
ENERGY STAR water heater model · PD 2408686

Takagi TK-540P-PEH 1*1 Water Heater Specifications (0.95 UEF)

Certified at 0.95 UEF, Takagi TK-540P-PEH 1*1 (Gas Tankless, Propane) places #159 of 464 out of 464 ENERGY STAR models (PD 2408686). Its May 6, 2029 10 CFR 430.32 status reads Pass: +0.04 / +4.4%. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Uniform Energy Factor
0.95 UEF
Cohort UEF Rank
#159 of 464
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.04 / +4.4%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Takagi TK-540P-PEH 1*1 at 0.95 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Takagi TK-540P-PEH 1*1: 0.95
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Takagi TK-540P-PEH 1*1 relative to the cohort median.
Efficiency comparison & rule summary

Tested at 0.95 UEF, Takagi TK-540P-PEH 1*1 places #159 of 464 across 464 certified Gas Tankless configurations (At 0.95 UEF median).

Operating on Propane, Takagi TK-540P-PEH 1*1 beats the 2029 0.91 UEF floor by +0.04 UEF (+4.4%).

Closest alternatives to Takagi TK-540P-PEH 1*1 include A. O. Smith ACT-199O-N 1** (0.95 UEF, at parity) alongside American GT-240-NEH 1** (0.95 UEF, at parity).

How Do Takagi TK-540P-PEH 1*1 Specs Compare to Gas Tankless Medians?

Takagi TK-540P-PEH 1*1 places #159 of 464 across 464 certified Gas Tankless configurations, with physical dimensions, draw profile, and thermal metrics benchmarked below.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandTakagi16 certified listingsENERGY STAR PD 2408686
Model NumberTK-540P-PEH 1*1Draw pattern: High-UsageTK-540P-PEH 1*1
Uniform Energy Factor (UEF)0.95At 0.95 UEF median10 CFR 430 Test Method
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2023-02-23Certified 2023-02-23Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Are There Active CPSC Safety Recalls for Takagi Water Heaters?

Zero active CPSC recalls matched Takagi in our 2026-11-23 SaferProducts sweep; verify your individual tank date code via our lookup tool. See Serial Number Lookup.

Which Certified Water Heaters Match TK-540P-PEH 1*1 Most Closely?

These 5 competing Gas Tankless units sit nearest to Takagi TK-540P-PEH 1*1 by storage capacity and 0.95 UEF rating.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
A. O. Smith ACT-199O-N 1** Gas Tankless — — 0.95 (at parity) —
American GT-240-NEH 1** Gas Tankless — — 0.95 (at parity) —
Bosch T9800 SE 160 Gas Tankless — — 0.95 (at parity) —
Bradford White RTG-K-160N1 Gas Tankless — — 0.95 (at parity) —
A. O. Smith ACT-199O-P 1*1 Gas Tankless — — 0.95 (at parity) —

When Should Homeowners Skip Takagi TK-540P-PEH 1*1 (Gas Tankless)?

Check Takagi TK-540P-PEH 1*1's mechanical constraints—including utility space, Propane capacity, and Pass: +0.04 / +4.4% status—against typical residential installations.

Key Limitations & Exclusions

  • Converting a 40K tank to Takagi TK-540P-PEH 1*1 often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Takagi TK-540P-PEH 1*1's heat exchanger.
  • Condensing Takagi TK-540P-PEH 1*1 requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Takagi TK-540P-PEH 1*1 delivers continuous 0.95 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

What Are the Key Questions About Takagi TK-540P-PEH 1*1?

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Will Takagi TK-540P-PEH 1*1 stay compliant after the May 6, 2029 DOE standard takes effect?

Tested at 0.95 UEF, Takagi TK-540P-PEH 1*1 shows Pass: +0.04 / +4.4% relative to May 6, 2029 federal DOE limits while placing #159 of 464 among 464 Gas Tankless peers like A. O. Smith ACT-199O-N 1**.

Will Takagi TK-540P-PEH 1*1 fit through a standard utility door and 72-inch basement ceiling?

Using a wall-mounted gas tankless chassis, Takagi TK-540P-PEH 1*1 eliminates floor-tank footprint (wall-hung / compact envelope), though Category IV exhaust and drain clearance remain mandatory.

Do existing utility hookups support Takagi TK-540P-PEH 1*1 during replacement?

Fueled by Propane, Takagi TK-540P-PEH 1*1 specifies: 120V AC ignition/fan + gas piping check. Always measure developed gas pipe length because high-BTU burners frequently require 3/4 in. or 1 in. Schedule 40 supply.

What is the estimated 10-year operating spend for Takagi TK-540P-PEH 1*1?

Because Takagi TK-540P-PEH 1*1 burns Propane at 0.95 UEF, operating bills track local natural gas or propane pricing rather than kWh tariffs across 464 peers.

When is Takagi TK-540P-PEH 1*1 a poor fit for a residential replacement?

Skip Takagi TK-540P-PEH 1*1 as a quick swap when long 1/2 in. iron gas lines starve ignition (triggering E003/11 codes) or when Type B metal chimney vents cannot handle condensing PVC.

What First Hour Rating or flow capacity does Takagi TK-540P-PEH 1*1 deliver?

As an on-demand Gas Tankless model, Takagi TK-540P-PEH 1*1 has no tank depletion limit—verify GPM output at your state's 40–65 °F winter water rise.

How do you verify manufacturing age and recall status on Takagi TK-540P-PEH 1*1?

Our 2026-11-23 CPSC SaferProducts feed lists zero recalls for Takagi; verify exact manufacturing week for Takagi TK-540P-PEH 1*1 using the Serial Number Lookup tool.

Does Takagi TK-540P-PEH 1*1 qualify for DOE HEAR incentives after 25C expired?

After 25C sunset on Dec 31, 2025 under OBBBA, check state DOE HEAR (up to $1,750 income-qualified) and utility rebates for Takagi TK-540P-PEH 1*1. Closest peer in Gas Tankless is A. O. Smith ACT-199O-N 1** (0.95 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks