Skip to main content
ENERGY STAR water heater model · PD 3554048

Tychon FPS/HP 300 Water Heater Specifications (5.4 SUEF)

With PD 3554048 certification, Tychon FPS/HP 300 (Solar with Electric Backup, Solar + Electric Backup) achieves a certified 5.4 SUEF rating across its 79-gallon nominal tank, standing #23 of 30 across 30 peers with Exempt — Solar SUEF for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and wall-hung / compact envelope. Closest certified alternative is Dimas 300-2 (99.0 SUEF).

Solar UEF (SUEF)
5.4 SUEF
Cohort SUEF Rank
#23 of 30
First Hour Rating
On-Demand
Storage Volume
79 gal
Fuel / Type
Solar + Electric Backup / Solar with Electric Backup
DOE 2029 Rule Status
Exempt — Solar SUEF
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Hybrid heat pump water heater upper shroud with brass relief valve and insulated copper risers
Solar with Electric Backup SUEF Efficiency Distribution (30 Certified Units)Distribution of certified SUEF ratings across 30 units in Solar with Electric Backup, marking Tychon FPS/HP 300 at 5.4 SUEF.171123.30 SUEF99.00 SUEFMedian 10.85Tychon FPS/HP 300: 5.40
Solar with Electric Backup SUEF Efficiency Distribution (30 Certified Units). Highlighted pin shows Tychon FPS/HP 300 relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Tychon FPS/HP 300 at 5.4 SUEF (#23 of 30; -5.45 SUEF vs. 10.85 SUEF median) in Solar with Electric Backup.

Solar collector & storage profile, OG-300 #30004358 for Tychon FPS/HP 300: Direct Thermosyphon architecture; 43.1 sq ft Flat Plate collector; 79 gal storage tank; freeze limit 39 deg F.

In the Solar with Electric Backup tier, Dimas 300-2 (99.0 SUEF, delta +93.60) and Solahart ASE 302J (9.0 SUEF, delta +3.60) bracket Tychon FPS/HP 300.

Which Specs Set Tychon FPS/HP 300 Apart From Cohort Averages?

Ranked #23 of 30 inside the 30-model Solar with Electric Backup cohort, Tychon FPS/HP 300 is evaluated row by row below against category medians.

Certified model attributes compared against 30 ENERGY STAR Solar with Electric Backup peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandTychon1 certified listingENERGY STAR PD 3554048
Model NumberFPS/HP 300Draw pattern: Medium-UsageFPS/HP 300
Solar Uniform Energy Factor (SUEF)5.4-5.45 SUEF vs. 10.85 SUEF median10 CFR 430 Test Method
Solar System & CollectorDirect Thermosyphon (Flat Plate)43.1 sq ft apertureOG-300 #30004358
Collector Freeze Tolerance39 °FSRCC freeze protection ratingENERGY STAR Solar Dataset
Electrical Circuit Requirements220 VCollector loop pump / controller + backup element checkNEC / Branch circuit check
Certification Date2024-07-01Certified 2024-07-01Markets: United States

What Should Tychon Owners Check in CPSC Recall Logs?

The 2026-11-23 CPSC recall sweep recorded zero brand matches for Tychon; run a quick serial-number check to verify age before replacing wear parts. See Serial Number Lookup.

How Do Five Nearby Solar with Electric Backup Models Stack Up?

Five alternative Solar with Electric Backup units with nearly identical gallon storage and SUEF scores are listed below alongside exact efficiency spreads.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRSUEF (Δ)kWh/yr
Dimas 300-2 Solar with Electric Backup 79 gal — 99.0 (+93.60) —
Solahart ASE 302J Solar with Electric Backup 79 gal — 9.0 (+3.60) —
Acevedo Unit 2-20 Solar with Electric Backup 80 gal — 99.0 (+93.60) —
AET DX-80-64 Solar with Electric Backup 80 gal — 99.0 (+93.60) —
Dimas 300-3 EL Solar with Electric Backup 79 gal — 12.1 (+6.70) —

Which Home Setups Are NOT a Fit for Tychon FPS/HP 300?

Comparing Tychon FPS/HP 300 against Dimas 300-2 requires checking closet airflow, IFGC gas or 240V electrical sizing, and May 6, 2029 compliance.

Key Limitations & Exclusions

  • Tychon FPS/HP 300 logs 5.4 SUEF (Exempt — Solar SUEF); check May 6, 2029 10 CFR 430.32 transition status.
  • Drain tank sediment yearly and inspect Tychon FPS/HP 300's sacrificial anode rod every 4–6 years.
  • Peak simultaneous draws exceeding 79 gal will deplete stored recovery capacity.

Which Option Fits Your Situation?

Direct Footprint Replacement for Tychon FPS/HP 300 Strong Fit — Matches existing plumbing and vent clearances.
2026 Post-OBBBA Rebate Buyers Verify Tier — DOE HEAR ($1,750 max) targets >=2.30 UEF heat pump models like Dimas 300-2.
Very Hard Well Water (>10.5 GPG) Add Softener / Flush — Schedule 6-month tank sediment drains.

Frequently Asked Technical Questions: Tychon FPS/HP 300

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Tychon FPS/HP 300 score under 10 CFR 430.32 May 2029 water heater minimums?

Under 10 CFR 430.32, solar models like Tychon FPS/HP 300 (5.4 SUEF) are evaluated by Solar Uniform Energy Factor rather than standard electric or gas tank thresholds.

What physical clearance dimensions apply when installing Tychon FPS/HP 300?

Because Tychon FPS/HP 300 is a solar with electric backup unit (wall-hung / compact envelope), check wall-stud backing, condensate neutralizer routing, and outdoor vent clearances first.

What 240V circuit or IFGC fuel line capacity fits Tychon FPS/HP 300?

Powered via 220V, Tychon FPS/HP 300 requires: Collector loop pump / controller + backup element check. Confirm double-pole breaker sizing and condensate pump outlet proximity.

How do state electricity prices change annual costs for Tychon FPS/HP 300?

Tychon FPS/HP 300 operates on Solar + Electric Backup (5.4 SUEF); check regional therm costs and hot-water recirculation schedules since tankless standby electricity stays minimal.

What homeowner setups should avoid choosing Tychon FPS/HP 300?

Homes with >10.5 GPG Very Hard well water without regular 6-month sediment draining will shorten the tank life of Tychon FPS/HP 300 (Exempt — Solar SUEF).

Is Tychon FPS/HP 300 sized adequately for a 2-to-4-person household?

Instead of First Hour Rating, Tychon FPS/HP 300 heats water continuously; two concurrent 2.0 GPM showers and a faucet require ~5.5 GPM at a 70 °F temperature rise.

Does Tychon have active CPSC SaferProducts notices affecting FPS/HP 300?

Zero CPSC recall alerts matched Tychon (2026-11-23 check). Keep your Tychon FPS/HP 300 serial code handy to track standard 6-to-12-year OEM warranty coverage.

Which competing water heater matches Tychon FPS/HP 300 (5.4 SUEF) most closely?

State-run DOE HEAR programs (<=150% AMI, up to $1,750 for HPWH) and electric utilities lead 2026 incentives for Tychon FPS/HP 300. Closest peer in Solar with Electric Backup is Dimas 300-2 (99.0 SUEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks