Skip to main content
ENERGY STAR water heater model · PD 4518058

Vesta VTP-199 Water Heater Specifications (0.96 UEF)

With PD 4518058 certification, Vesta VTP-199 (Gas Tankless, Natural Gas, Propane) achieves a certified 0.96 UEF rating, standing #39 of 464 across 464 peers with Pass: +0.05 / +5.5% for May 6, 2029. Annual fuel cost depends on regional gas/fuel tariffs and fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.1" d). Closest certified alternative is Bradford White RTGR199N1** (0.96 UEF).

Uniform Energy Factor
0.96 UEF
Cohort UEF Rank
#39 of 464 (top 34.1%)
First Hour Rating
On-Demand
Storage Volume
Tankless
Fuel / Type
Natural Gas, Propane / Gas Tankless
DOE 2029 Rule Status
Pass: +0.05 / +5.5%
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Open interior view of wall-mounted condensing tankless water heater copper heat exchanger coils
Gas Tankless UEF Efficiency Distribution (464 Certified Units)Distribution of certified UEF ratings across 464 units in Gas Tankless, marking Vesta VTP-199 at 0.96 UEF.3061205330.95 UEF0.98 UEFMedian 0.952029 min 0.91Vesta VTP-199: 0.96
Gas Tankless UEF Efficiency Distribution (464 Certified Units). Highlighted pin shows Vesta VTP-199 relative to the cohort median.
Efficiency comparison & rule summary

ENERGY STAR certification places Vesta VTP-199 at 0.96 UEF (#39 of 464; +0.01 UEF vs. 0.95 UEF median) in Gas Tankless.

With Natural Gas, Propane condensing combustion, Vesta VTP-199 stands +0.05 UEF (+5.5%) above the 2029 0.91 UEF minimum; thermal recovery tests at 98% (At 98.0% median).

In the Gas Tankless tier, Bradford White RTGR199N1** (0.96 UEF, at parity) and Friedrich FDTGH-S10I (0.96 UEF, at parity) bracket Vesta VTP-199.

What Physical and Thermal Ratings Define Vesta VTP-199?

Positioning at #39 of 464 (top 34.1%) out of 464 Gas Tankless peers, Vesta VTP-199 pairs measured UEF performance with specific clearance and wiring rules.

Certified model attributes compared against 464 ENERGY STAR Gas Tankless peers
Specification AttributeCertified ValueCohort Benchmark / DeltaProvenance
Manufacturer / BrandVesta9 certified listingsENERGY STAR PD 4518058
Model NumberVTP-199Draw pattern: High-UsageVTP-199
Uniform Energy Factor (UEF)0.96+0.01 UEF vs. 0.95 UEF median10 CFR 430 Test Method
Thermal Recovery Efficiency98%At 98.0% medianENERGY STAR Dataset
Physical Envelope (H x Dia)27.6" H x 18.1" DFits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.1" D)Doorway & ceiling check
Electrical Circuit Requirements5 A max120V AC ignition/fan + gas piping checkNEC / Branch circuit check
Certification Date2025-12-12Certified 2025-12-12Markets: United States, Canada
Condensing Gas Tankless vs. Storage Tank Flow Path & Gas Supply Engineering schematic contrasting 199,000 BTU/h condensing tankless piping (3/4 in. gas supply, Category IV PVC vent, condensate drain) against a 40,000 BTU/h atmospheric tank. Condensing Gas Tankless (0.91–0.96 UEF) Secondary HX Cat IV PVC Vent Cold In Hot Out 3/4"–1" Gas 199K BTU/h Condensate Atmospheric Storage Tank (0.58–0.65 UEF) Type B Flue Anode Rod 40K BTU/h 1/2" Gas Up to 100 ft T&P 150 psi 50–85 gal FHR Reserve | 8–12 yr life
Technical comparison: condensing gas tankless units require 3/4 in.–1 in. IFGC Table 402.4 gas supply and Category IV condensate drainage, while atmospheric tanks run on 1/2 in. lines.

Have Any Vesta Series Triggered CPSC Recalls?

SaferProducts records retrieved 2026-11-23 list 1 brand notice under Vesta; inspect model coverage dates prior to valve or anode service. See Serial Number Lookup.

1 Brand Recall Notice Found in CPSC Feed — Verify Serial & Model Range
  • Recall #26026 (2025-10-16): VESTA.DS Recalls VST Brand Tankless Water Heaters Due to Carbon Monoxide (CO) Poisoning Hazard and Risk of Serious Injury and Death (CPSC Notice)

What Are 5 Direct Alternatives to Vesta VTP-199?

Homeowners cross-shopping Vesta VTP-199 frequently review these five Gas Tankless models ranked closest on capacity and UEF output.

5 closest certified peers matched by equipment class, storage volume, and efficiency rating
Brand & ModelTypeVolFHRUEF (Δ)kWh/yr
Bradford White RTGR199N1** Gas Tankless — — 0.96 (at parity) —
Friedrich FDTGH-S10I Gas Tankless — — 0.96 (at parity) —
Kepler JSG48-29PCH/180K Gas Tankless — — 0.96 (at parity) —
Kings Peak KNG199ICW Gas Tankless — — 0.96 (at parity) —
Bradford White RTGR199X1** Gas Tankless — — 0.96 (at parity) —

What Are the Limitations of Vesta VTP-199 and Who Should Not Install It?

Before ordering Vesta VTP-199 (Gas Tankless, 0.96 UEF), weigh space clearances, fuel piping, noise (standard dBA), and 2029 rule readiness across three scenarios.

Key Limitations & Exclusions

  • Converting a 40K tank to Vesta VTP-199 often requires 3/4 in.–1 in. IFGC Table 402.4 gas line upsizing.
  • Hard tap water >=7.0 GPG requires annual vinegar descaling to protect Vesta VTP-199's heat exchanger.
  • Condensing Vesta VTP-199 requires Category IV PVC/polypropylene exhaust and condensate drain rather than Type B metal flues.

Which Option Fits Your Situation?

Existing 3/4 in.+ Gas Line + Marathon Hot Draws Strong Fit — Vesta VTP-199 delivers continuous 0.96 UEF performance.
Softened/Low-Scale Water (<7.0 GPG) Strong Fit — Minimal calcium scale between 12-month flushes.
Long 1/2 in. Gas Run (>10 ft) Not Recommended — Fails 199 CFH IFGC capacity; triggers E003/11 ignition lockouts.

Sizing, Efficiency & Recall Answers for Vesta VTP-199

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Vesta VTP-199 pass the May 6, 2029 federal DOE efficiency rule?

Vesta VTP-199 carries a verified 0.96 UEF rating (Pass: +0.05 / +5.5%), ranking #39 of 464 (top 34.1%) across 464 ENERGY STAR Gas Tankless models under 10 CFR 430.32.

What doorway width and ceiling height does Vesta VTP-199 need?

Vesta VTP-199 stands 27.6 in. high with a 18.1 in. diameter; fits standard 72 in. basement/garage clearance; clears 28 in. utility doorway (18.1" d). Leave overhead clearance for dielectric nipples, ball shutoff valves, and top air filters.

What gas pipe size or electrical breaker does Vesta VTP-199 require?

Vesta VTP-199 runs on Natural Gas, Propane (120V AC ignition/fan + gas piping check). Upgrading from a 40K tank to 199K BTU/h tankless demand requires checking IFGC Table 402.4(2), since 1/2 in. iron pipe drops below 199 CFH past 10 ft.

How much electricity or energy does Vesta VTP-199 cost per year to run?

ENERGY STAR rates Vesta VTP-199 as a Natural Gas, Propane heater (0.96 UEF) without an electric kWh figure; annual fuel spend depends on local therm rates and Gas Tankless draw.

Who should NOT install Vesta VTP-199, and what are its limits?

Vesta VTP-199 (0.96 UEF) is rarely a drop-in swap over a 40K tank if existing 1/2 in. gas pipe cannot supply 199,000 BTU/h or hardness exceeds 7.0 GPG without descaling.

How many bathrooms or people can Vesta VTP-199 serve at peak demand?

Vesta VTP-199 provides continuous Gas Tankless delivery rather than a fixed storage FHR; size GPM flow against winter incoming groundwater temperature and 2.0 GPM showers.

Are there CPSC safety recalls or serial checks for Vesta VTP-199?

CPSC SaferProducts records show 1 brand-level recall notice mentioning Vesta as of 2026-11-23, including #26026 (2025-10-16). Enter the rating-plate serial into TapAndPipe's Serial Lookup tool to verify production week.

What 2026 rebates apply to Vesta VTP-199, and what peer compares closest?

Federal Section 25C expired Dec 31, 2025 (P.L. 119-21); qualifying HPWHs remain eligible for state DOE HEAR rebates up to $1,750 (<=150% AMI). Closest peer in Gas Tankless is Bradford White RTGR199N1** (0.96 UEF).

Sources

  1. ENERGY STAR Certified Water Heaters Dataset (Socrata pbpq-swnu) — U.S. EPA & DOE ENERGY STAR, 2026 Live Certified Registry (retrieved 2026-11-23)
  2. 10 CFR 430.32 — Energy and Water Conservation Standards (Water Heaters & Plumbing Fixtures) — U.S. Department of Energy / eCFR, 2026 eCFR (incl. May 6, 2029 Rule) (retrieved 2026-11-23)
  3. CPSC SaferProducts.gov Product Recalls REST API — U.S. Consumer Product Safety Commission, 2026 Live Recalls Feed (retrieved 2026-11-23)

Related U.S. Metro Plumbing Benchmarks