Polacca Water Quality, PFAS & Utility Report (090400106)
Ranked #148 of 161 major community water utilities in Arizona, Polacca (090400106) delivers ground water purchased to 3,890 people around First Mesa Consolidated Villages. Public records indicate an active EPA health-based flag (6 3-yr rule notices, 12 non-compliant quarters) and note that all 60 federal UCMR 5 PFAS lab runs tested non-detect. Recommended home check: Match NSF 53/58 filter to cited CCR contaminant.
- EPA PWSID
- 090400106
- Population Served
- 3,890
- Water Source
- Groundwater
- Max UCMR 5 PFAS
- 0 ppt Detected
- 3-Yr Health Flags
- 6 flagged
Because Polacca relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Arizona's statewide USGS median is 13.0 GPG (Very Hard). This system logged a recent EPA SDWA health-based notice; review your annual Consumer Confidence Report contaminant list before selecting RO or specialized media.
Across 825 housing units in Polacca's 1 ZIP code (median value $61,000), 26.5% predates 1980 (16.7% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.
Which Compliance and Housing Indicators Define 090400106?
These verified utility measurements pair EPA SDWIS facility data for Polacca with Census housing vintage across its 1 served ZIP codes.
| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | 090400106 (Tribal Government) | Active CWS | Last sanitary visit: 10/23/2025 |
| Primary Source Water | Ground Water Purchased | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 3,890 residents | #148 in Arizona | Counties: Arizona |
| Served ZIP Codes | 86042 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 26.5% (16.7% pre-1960) | 1986 Lead Ban | Mostly post-1980 copper or PEX piping |
| 3-Year EPA SDWA Compliance | 6 rule violations (12 qtrs) | Zero health flags target | 0700=Groundwater Rule, 0999=Chlorine, 1005=Arsenic, 3014=E. Coli |
| State Tap Hardness Baseline | 13.0 GPG (Very Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |
How Do Polacca PFAS Levels Stack Up Against 4.0 ppt Rules?
EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Polacca's monitored results below.
| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
What Do Neighboring Community Water Systems Report in Arizona?
Cross-check four peer Arizona water utilities to see how Polacca ranks by system size, groundwater reliance, and EPA notices.
| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| Ganado-Burnside-Cornfield-Steamboat NTUA (NN0403001) | Ganado, Cornfield, Steamboat, Woodspring | 3,947 | Groundwater | 0 |
| Graham County Utilities - Pima (AZ0405002) | Pima | 3,899 | Groundwater | 0 |
| Kayenta NTUA (NN0403003) | Kayenta | 3,844 | Groundwater | 0 |
| Spanish Trail Water Company (AZ0410127) | Tucson | 3,822 | Groundwater | 0 |
When Should Polacca Homeowners Upgrade Filtration or Test at the Tap?
Municipal utility compliance reports end at the street meter in First Mesa Consolidated Villages; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.
Key Limitations & Exclusions
- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.
Which Option Fits Your Situation?
Key Questions About Tap Water From Polacca
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
What water source serves the 3,890 customers under EPA ID 090400106?
EPA ECHO classifies Polacca (090400106) as a Ground Water Purchased community system serving 3,890 residents across Arizona. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.
How do Polacca PFAS levels compare to EPA's 4.0 ppt federal limit?
Federal UCMR 5 sampling covering 60 laboratory tests for Polacca reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.
What pipe materials should homeowners served by Polacca inspect?
Across the 1 ZIP codes served by Polacca, approximately 26.5% of residential housing units were built before 1980 (16.7% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.
Sources
- EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
- Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
- PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
- Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
- National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
- U.S. Census American Community Survey (ACS) 2019โ2023 5-Year Summary File — U.S. Census Bureau, 2019โ2023 5-Year Estimates (retrieved 2026-11-25)