Globe City Of Water Quality, PFAS & Utility Report (AZ0404008)
Operating under Local Government management in Globe, Arizona, Globe City Of (AZ0404008) serves 7,536 residents via ground water. Federal screening logs show zero EPA health violations alongside 4 monitoring/reporting notices, UCMR 5 samples measured 113.3 ppt for PFBS (exceeding the 4.0 ppt federal rule), making install nsf 58 ro + whole-house pre-filter the primary home filtration takeaway.
- EPA PWSID
- AZ0404008
- Population Served
- 7,536
- Water Source
- Groundwater
- Max UCMR 5 PFAS
- 113.3 ppt (PFBS)
- 3-Yr Health Flags
- 0 Health Viol.
Because Globe City Of relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Arizona's statewide USGS median is 13.0 GPG (Very Hard). UCMR 5 samples reached 113.3 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.
Across 7,995 housing units in Globe City Of's 3 ZIP codes (median value $132,867), 65.8% predates 1980 (35.7% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.
What Should Globe Homeowners Know About Globe City Of?
Key federal SDWIS metrics for AZ0404008 are tabulated alongside USGS state hardness and pre-1980 building share to guide repipe or filter choices.
| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | AZ0404008 (Local Government) | Active CWS | Last sanitary visit: 12/19/2024 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 7,536 residents | #95 in Arizona | Counties: Gila |
| Served ZIP Codes | 85501, 85532, 85539 | 3 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 65.8% (35.7% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 4 rule violations (10 qtrs) | Zero health flags target | 1040=Nitrate, 2456=Total Haloacetic Acids (Haa5), 2950=Tthm, 8000=Revised Total Coliform Rule |
| State Tap Hardness Baseline | 13.0 GPG (Very Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |
What Does UCMR 5 Testing Reveal About AZ0404008?
Review specific PFAS detections, non-detects, and federal 4.0–10 ppt benchmarks recorded for Globe City Of in EPA's national monitoring database.
| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | 9.5 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | 23.7 ppt | 10 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
Where Can You Compare Globe City Of With Other Arizona Systems?
Four peer Arizona utilities below let homeowners compare municipal groundwater versus surface water exposure across neighboring towns.
| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| Pine Strawberry Wid (AZ0404034) | Pine | 8,013 | Groundwater | 0 |
| Buckeye City Of (AZ0407089) | Buckeye | 7,998 | Groundwater | 0 |
| Page City Of (AZ0403017) | Page | 7,445 | Surface / Mixed | 0 |
| Big Park Water Company (AZ0413012) | Sedona | 7,392 | Groundwater | 6 |
When Should Globe City Of Homeowners Upgrade Filtration or Test at the Tap?
Municipal utility compliance reports end at the street meter in Globe; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.
Key Limitations & Exclusions
- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.
Which Option Fits Your Situation?
Common Questions for Globe City Of Tap Water Customers
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Is tap water from Globe City Of surface-treated or well-sourced?
EPA ECHO classifies Globe City Of (AZ0404008) as a Ground Water community system serving 7,536 residents across Gila. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.
Did Globe City Of exceed EPA's 4.0 ppt PFOA or PFOS standard?
Yes—UCMR 5 laboratory testing for AZ0404008 recorded 6 PFAS detections peaking at 113.3 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.
Are pre-1980 copper solder or galvanized lines common in Globe City Of's ZIP codes?
Across the 3 ZIP codes served by Globe City Of, approximately 65.8% of residential housing units were built before 1980 (35.7% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.
Sources
- EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
- Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
- PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
- Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
- National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
- U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)