Skip to main content
Community water audit · AZ0407095 in AZ

Mesa City Of Water Quality, PFAS & Utility Report (AZ0407095)

Homeowners connected to Mesa City Of (AZ0407095) in Mesa, Arizona receive surface water across a 466,000-person distribution network. EPA SDWIS records document zero EPA health violations alongside 3 monitoring/reporting notices; under UCMR 5 monitoring, UCMR 5 samples measured 15.2 ppt for PFBS (exceeding the 4.0 ppt federal rule), and 30.0% of homes across 16 served ZIP codes predate 1980.

EPA PWSID
AZ0407095
Population Served
466,000
Water Source
Surface Water
Max UCMR 5 PFAS
15.2 ppt (PFBS)
3-Yr Health Flags
0 Health Viol.
Water chemistry briefing — Mesa City Of

Drawing surface water across Mesa, Mesa City Of uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 15.2 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 260,620 housing units in Mesa City Of's 16 ZIP codes (median value $367,686), 30.0% predates 1980 (4.3% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

How Clean and Hard Is Tap Water Supplied by Mesa City Of?

Examine Mesa City Of's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Maricopa.

EPA SDWA and local housing profile for Mesa City Of (AZ0407095)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership AZ0407095 (Local Government) Active CWS Last sanitary visit: 11/26/2024
Primary Source Water Surface Water GW vs. SW Disinfection byproduct check recommended
Service Area & Population 466,000 residents #3 in Arizona Counties: Maricopa
Served ZIP Codes 85201, 85202, 85203, 85204, 85205, 85206, 85207, 85208 (+8 more) 16 ZIP codes Verify utility on local municipal water bill
Pre-1980 Housing Share 30.0% (4.3% pre-1960) 1986 Lead Ban Mostly post-1980 copper or PEX piping
3-Year EPA SDWA Compliance 3 rule violations (4 qtrs) Zero health flags target 1011=Bromate, 2378=1, 2, 4-Trichlorobenzene
State Tap Hardness Baseline 13.0 GPG (Very Hard) >= 7.0 GPG = Hard Size ion-exchange resin on local grain test

Are Forever Chemicals Detected in Mesa City Of Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify AZ0407095's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for AZ0407095
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS 9.3 ppt 10 ppt EPA MCL Detected below final EPA federal MCL
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Who Are the Closest Arizona Community System Peers?

Compare four other Arizona utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Arizona for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Phoenix City Of (AZ0407025) Phoenix 1,695,000 Surface / Mixed 0
Tucson City Of (AZ0410112) Tucson 732,906 Groundwater 0
Gilbert, Town Of (AZ0407092) Gilbert 247,600 Surface / Mixed 0
Chandler City Of (AZ0407090) Chandler 247,328 Surface / Mixed 0

When Should Mesa City Of Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Mesa; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (13.0 GPG) and add scale inhibition on groundwater feeds.

Drinking Water & Pipe Safety FAQs: AZ0407095

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Mesa City Of's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Mesa City Of (AZ0407095) as a Surface Water community system serving 466,000 residents across Maricopa. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Should Mesa City Of homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for AZ0407095 recorded 14 PFAS detections peaking at 15.2 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

Does EPA's 10 ppb LCRI lead rule apply to houses on Mesa City Of?

Across the 14 ZIP codes served by Mesa City Of, approximately 30.0% of residential housing units were built before 1980 (4.3% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks