Skip to main content
Community water audit · 090605153 in CA

Pala North Water Quality, PFAS & Utility Report (090605153)

Homeowners connected to Pala North (090605153) in California, California receive ground water across a 14,280-person distribution network. EPA SDWIS records document an active EPA health-based flag (3 3-yr rule notices, 12 non-compliant quarters); under UCMR 5 monitoring, UCMR 5 samples measured 12.0 ppt for PFBS (exceeding the 4.0 ppt federal rule), and 40.0% of homes across 1 served ZIP code predate 1980.

EPA PWSID
090605153
Population Served
14,280
Water Source
Groundwater
Max UCMR 5 PFAS
12.0 ppt (PFBS)
3-Yr Health Flags
3 flagged
Water chemistry briefing — Pala North

Because Pala North relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; California's statewide USGS median is 36.1 GPG (Very Hard). UCMR 5 samples reached 12.0 ppt for PFBS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 475 housing units in Pala North's 1 ZIP code (median value $506,600), 40.0% predates 1980 (4.2% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

How Clean and Hard Is Tap Water Supplied by Pala North?

Examine Pala North's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in California.

EPA SDWA and local housing profile for Pala North (090605153)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership 090605153 (Tribal Government) Active CWS Last sanitary visit: 06/04/2025
Primary Source Water Ground Water GW vs. SW Harder mineral load expected
Service Area & Population 14,280 residents #379 in California Counties: California
Served ZIP Codes 92059 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 40.0% (4.2% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 3 rule violations (12 qtrs) Zero health flags target 0700=Groundwater Rule, 1040=Nitrate, 8000=Revised Total Coliform Rule
State Tap Hardness Baseline 36.1 GPG (Very Hard) >= 7.0 GPG = Hard Size ion-exchange resin on local grain test

Are Forever Chemicals Detected in Pala North Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify 090605153's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for 090605153
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA 6.1 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Who Are the Closest California Community System Peers?

Compare four other California utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in California for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
City Of Modesto - Salida (CA5010005) Modesto 14,576 Surface / Mixed 0
City Of Red Bluff (CA5210004) Red Bluff 14,286 Groundwater 0
California City, City Of (CA1510032) California City 14,198 Surface / Mixed 0
Mcfarland, City Of (CA1510013) Mcfarland 14,161 Groundwater 0

When Should Pala North Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in California; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (36.1 GPG) and add scale inhibition on groundwater feeds.

Drinking Water & Pipe Safety FAQs: 090605153

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Pala North's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Pala North (090605153) as a Ground Water community system serving 14,280 residents across California. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

Should Pala North homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for 090605153 recorded 7 PFAS detections peaking at 12.0 ppt (PFBS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

Does EPA's 10 ppb LCRI lead rule apply to houses on Pala North?

Across the 1 ZIP codes served by Pala North, approximately 40.0% of residential housing units were built before 1980 (4.2% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks