City Of Bell Gardens Water Quality, PFAS & Utility Report (CA1910108)
Ranked #416 of 669 major community water utilities in California, City Of Bell Gardens (CA1910108) delivers surface water purchased to 11,413 people around Bell Gardens. Public records indicate zero 3-year EPA health or monitoring rule violations on record and note that UCMR 5 samples measured 23.0 ppt for PFOS (exceeding the 4.0 ppt federal rule). Recommended home check: Install NSF 58 RO + whole-house pre-filter.
- EPA PWSID
- CA1910108
- Population Served
- 11,413
- Water Source
- Surface Water
- Max UCMR 5 PFAS
- 23.0 ppt (PFOS)
- 3-Yr Health Flags
- 0 Health Viol.
Drawing surface water across Bell Gardens, City Of Bell Gardens uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 23.0 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.
Across 24,989 housing units in City Of Bell Gardens's 1 ZIP code (median value $542,800), 74.8% predates 1980 (49.7% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.
Which Compliance and Housing Indicators Define CA1910108?
These verified utility measurements pair EPA SDWIS facility data for City Of Bell Gardens with Census housing vintage across its 1 served ZIP codes.
| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | CA1910108 (Local Government) | Active CWS | Last sanitary visit: 07/13/2022 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 11,413 residents | #416 in California | Counties: Los Angeles |
| Served ZIP Codes | 90201 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 74.8% (49.7% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | 36.1 GPG (Very Hard) | >= 7.0 GPG = Hard | Size ion-exchange resin on local grain test |
How Do City Of Bell Gardens PFAS Levels Stack Up Against 4.0 ppt Rules?
EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect City Of Bell Gardens's monitored results below.
| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | 14.0 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFOS | 23.0 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | 3.9 ppt | 10 ppt EPA MCL | Detected below final EPA federal MCL |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
What Do Neighboring Community Water Systems Report in California?
Cross-check four peer California water utilities to see how City Of Bell Gardens ranks by system size, groundwater reliance, and EPA notices.
| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| Camp Pendleton (North) (CA3710700) | San Diego | 11,576 | Groundwater | 0 |
| Ccwd - Ebbetts Pass (CA0510016) | Calaveras | 11,545 | Surface / Mixed | 0 |
| Plumas Lake (CA5805001) | Yuba | 11,374 | Groundwater | 0 |
| City Of Anderson (CA4510001) | Anderson | 11,323 | Groundwater | 1 |
When Should City Of Bell Gardens Homeowners Upgrade Filtration or Test at the Tap?
Municipal utility compliance reports end at the street meter in Bell Gardens; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.
Key Limitations & Exclusions
- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.
Which Option Fits Your Situation?
Key Questions About Tap Water From City Of Bell Gardens
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
What water source serves the 11,413 customers under EPA ID CA1910108?
EPA ECHO classifies City Of Bell Gardens (CA1910108) as a Surface Water Purchased community system serving 11,413 residents across Los Angeles. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.
How do City Of Bell Gardens PFAS levels compare to EPA's 4.0 ppt federal limit?
Yes—UCMR 5 laboratory testing for CA1910108 recorded 7 PFAS detections peaking at 23.0 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.
What pipe materials should homeowners served by City Of Bell Gardens inspect?
Across the 1 ZIP codes served by City Of Bell Gardens, approximately 74.8% of residential housing units were built before 1980 (49.7% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.
Sources
- EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
- Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
- PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
- Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
- National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
- U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)