Skip to main content
Safe drinking water record · CA3010064

City Of Westminster Water Quality, PFAS & Utility Report (CA3010064)

Operating under Local Government management in Westminster, California, City Of Westminster (CA3010064) serves 93,591 residents via surface water purchased. Federal screening logs show zero 3-year EPA health or monitoring rule violations on record, UCMR 5 samples measured 5.3 ppt for PFOS (exceeding the 4.0 ppt federal rule), making install nsf 58 ro + whole-house pre-filter the primary home filtration takeaway.

EPA PWSID
CA3010064
Population Served
93,591
Water Source
Surface Water
Max UCMR 5 PFAS
5.3 ppt (PFOS)
3-Yr Health Flags
0 Health Viol.
Local water quality & plumbing fit

Drawing surface water across Westminster, City Of Westminster uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 5.3 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 31,920 housing units in City Of Westminster's 2 ZIP codes (median value $771,850), 75.7% predates 1980 (24.1% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

What Should Westminster Homeowners Know About City Of Westminster?

Key federal SDWIS metrics for CA3010064 are tabulated alongside USGS state hardness and pre-1980 building share to guide repipe or filter choices.

EPA SDWA and local housing profile for City Of Westminster (CA3010064)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership CA3010064 (Local Government) Active CWS Last sanitary visit: 05/15/2025
Primary Source Water Surface Water Purchased GW vs. SW Disinfection byproduct check recommended
Service Area & Population 93,591 residents #100 in California Counties: Orange
Served ZIP Codes 92655, 92683 2 ZIP codes Verify utility on local municipal water bill
Pre-1980 Housing Share 75.7% (24.1% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 0 rule violations (0 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline 36.1 GPG (Very Hard) >= 7.0 GPG = Hard Size ion-exchange resin on local grain test

What Does UCMR 5 Testing Reveal About CA3010064?

Review specific PFAS detections, non-detects, and federal 4.0–10 ppt benchmarks recorded for City Of Westminster in EPA's national monitoring database.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for CA3010064
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS 5.3 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFHxS 5.0 ppt 10 ppt EPA MCL Detected below final EPA federal MCL
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Where Can You Compare City Of Westminster With Other California Systems?

Four peer California utilities below let homeowners compare municipal groundwater versus surface water exposure across neighboring towns.

Nearby community water systems in California for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Santa Cruz Water Department (CA4410010) Santa Cruz 94,626 Surface / Mixed 0
Padre Dam Mwd (CA3710037) San Diego 93,980 Surface / Mixed 0
Placer Cwa - Foothill (CA3110025) Placer 93,417 Surface / Mixed 0
City Of Santa Barbara Water Department (CA4210010) Santa Barbara 93,334 Surface / Mixed 0

When Should City Of Westminster Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Westminster; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (36.1 GPG) and add scale inhibition on groundwater feeds.

Common Questions for City Of Westminster Tap Water Customers

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Is tap water from City Of Westminster surface-treated or well-sourced?

EPA ECHO classifies City Of Westminster (CA3010064) as a Surface Water Purchased community system serving 93,591 residents across Orange. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Did City Of Westminster exceed EPA's 4.0 ppt PFOA or PFOS standard?

Yes—UCMR 5 laboratory testing for CA3010064 recorded 8 PFAS detections peaking at 5.3 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

Are pre-1980 copper solder or galvanized lines common in City Of Westminster's ZIP codes?

Across the 2 ZIP codes served by City Of Westminster, approximately 75.7% of residential housing units were built before 1980 (24.1% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)