Skip to main content
Utility quality file · Lewes, DE (DE0000602)

Lewes Board Of Public Works Water Quality, PFAS & Utility Report (DE0000602)

Supplying 9,627 customers across Sussex, Delaware, Lewes Board Of Public Works (EPA ID DE0000602) relies on ground water for daily municipal flow. Current federal compliance files record zero 3-year EPA health or monitoring rule violations on record; meanwhile UCMR 5 samples measured 9.5 ppt for PFOS (exceeding the 4.0 ppt federal rule), and 17.8% of homes across 1 served ZIP code predate 1980.

EPA PWSID
DE0000602
Population Served
9,627
Water Source
Groundwater
Max UCMR 5 PFAS
9.5 ppt (PFOS)
3-Yr Health Flags
0 Health Viol.
Tap treatment summary — DE0000602

Drawing surface water across Lewes, Lewes Board Of Public Works uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 9.5 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 19,410 housing units in Lewes Board Of Public Works's 1 ZIP code (median value $488,900), 17.8% predates 1980 (6.1% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

How Is Lewes Board Of Public Works's Municipal Water Supplied and Regulated?

Review Lewes Board Of Public Works's supply classification, customer headcount, local pre-1980 housing density, and 3-year Safe Drinking Water Act inspection metrics below.

EPA SDWA and local housing profile for Lewes Board Of Public Works (DE0000602)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership DE0000602 (Local Government) Active CWS Last sanitary visit: 04/15/2024
Primary Source Water Ground Water GW vs. SW Harder mineral load expected
Service Area & Population 9,627 residents #21 in Delaware Counties: Sussex
Served ZIP Codes 19958 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 17.8% (6.1% pre-1960) 1986 Lead Ban Mostly post-1980 copper or PEX piping
3-Year EPA SDWA Compliance 0 rule violations (0 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline Unmonitored in USGS extract >= 7.0 GPG = Hard Moderate mineral profile

What Do Federal PFAS Lab Results Show for Lewes Board Of Public Works?

See how Lewes Board Of Public Works (DE0000602) performed across federal UCMR 5 compounds alongside EPA's 4.0 ppt enforcement standard for PFOA and PFOS.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for DE0000602
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA 6.1 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFOS 9.5 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFHxS 3.5 ppt 10 ppt EPA MCL Detected below final EPA federal MCL
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
Lead / Copper 90th Pct Pb: 2 / Cu: — 10 ppb Lead (LCRI) / 1.3 ppm Cu Utility distribution sample

Which Nearby Delaware Water Utilities Match This Profile?

Compare population scale, water source, and compliance status across four comparable community systems operating in Delaware.

Nearby community water systems in Delaware for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Milford Water Department (DE0000616) Milford 9,800 Groundwater 0
Church Creek (Awc) (DE00A0428) Magnolia 9,654 Groundwater 0
Millsboro Water Department (DE0000622) Millsboro 8,568 Groundwater 0
Bayside Pump District (Tui) (DE00A0837) Fenwick Island 8,400 Groundwater 0

When Should Lewes Board Of Public Works Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Lewes; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

Practical Drinking Water Questions for Lewes Residents

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Lewes Board Of Public Works draw from groundwater aquifers or surface water reservoirs?

EPA ECHO classifies Lewes Board Of Public Works (DE0000602) as a Ground Water community system serving 9,627 residents across Sussex. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

What did federal UCMR 5 sampling measure in DE0000602?

Yes—UCMR 5 laboratory testing for DE0000602 recorded 4 PFAS detections peaking at 9.5 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

How does local home age affect plumbing risk inside DE0000602's service area?

Across the 1 ZIP codes served by Lewes Board Of Public Works, approximately 17.8% of residential housing units were built before 1980 (6.1% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks