Hudson Water Works Water Quality, PFAS & Utility Report (FL6512226)

Ranked #284 of 400 major community water utilities in Florida, Hudson Water Works (FL6512226) delivers ground water to 7,169 people around Hudson. Public records indicate zero EPA health violations alongside 4 monitoring/reporting notices and note that UCMR 5 samples measured 6.1 ppt for PFOS (exceeding the 4.0 ppt federal rule). Recommended home check: Install NSF 58 under-sink RO or NSF 53 PFAS carbon.

EPA PWSID
FL6512226
Population Served
7,169
Water Source
Groundwater
Max UCMR 5 PFAS
6.1 ppt (PFOS)
3-Yr Health Flags
0 Health Viol.
Homeowner takeaway for FL6512226

Because Hudson Water Works relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Florida's statewide USGS median is 2.3 GPG (Soft). UCMR 5 samples reached 6.1 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 19,651 housing units in Hudson Water Works's 1 ZIP code (median value $214,200), 37.4% predates 1980 (1.8% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

Which Compliance and Housing Indicators Define FL6512226?

These verified utility measurements pair EPA SDWIS facility data for Hudson Water Works with Census housing vintage across its 1 served ZIP codes.

EPA SDWA and local housing profile for Hudson Water Works (FL6512226)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership FL6512226 (Local Government) Active CWS Last sanitary visit: 01/19/2023
Primary Source Water Ground Water GW vs. SW Harder mineral load expected
Service Area & Population 7,169 residents #284 in Florida Counties: Pasco
Served ZIP Codes 34667 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 37.4% (1.8% pre-1960) 1986 Lead Ban Mostly post-1980 copper or PEX piping
3-Year EPA SDWA Compliance 4 rule violations (10 qtrs) Zero health flags target 1040=Nitrate, 2456=Total Haloacetic Acids (Haa5), 2950=Tthm, 3014=E. Coli
State Tap Hardness Baseline 2.3 GPG (Soft) >= 7.0 GPG = Hard Moderate mineral profile

How Do Hudson Water Works PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Hudson Water Works's monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for FL6512226
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA 4.3 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFOS 6.1 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

What Do Neighboring Community Water Systems Report in Florida?

Cross-check four peer Florida water utilities to see how Hudson Water Works ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in Florida for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Neptune Beach (FL2160206) Neptune Beach 7,270 Groundwater 0
Inverness Water Dept (FL6090861) Inverness 7,194 Groundwater 0
Town Of Longboat Key (FL6411098) Longboat Key 7,098 Surface / Mixed 0
Lady Lake Central - Wps 1,2,3 (FL3350977) Lady Lake 7,090 Groundwater 0

When Should Hudson Water Works Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Hudson; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (2.3 GPG) and add scale inhibition on groundwater feeds.

Key Questions About Tap Water From Hudson Water Works

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

What water source serves the 7,169 customers under EPA ID FL6512226?

EPA ECHO classifies Hudson Water Works (FL6512226) as a Ground Water community system serving 7,169 residents across Pasco. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

How do Hudson Water Works PFAS levels compare to EPA's 4.0 ppt federal limit?

Yes—UCMR 5 laboratory testing for FL6512226 recorded 6 PFAS detections peaking at 6.1 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

What pipe materials should homeowners served by Hudson Water Works inspect?

Across the 1 ZIP codes served by Hudson Water Works, approximately 37.4% of residential housing units were built before 1980 (1.8% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks