Skip to main content
Community water audit · GA0510001 in GA

Pooler Water Quality, PFAS & Utility Report (GA0510001)

Homeowners connected to Pooler (GA0510001) in Pooler, Georgia receive surface water purchased across a 28,423-person distribution network. EPA SDWIS records document zero EPA health violations alongside 1 monitoring/reporting notice; under UCMR 5 monitoring, UCMR 5 samples measured 5.0 ppt for PFOA (exceeding the 4.0 ppt federal rule), and 11.9% of homes across 1 served ZIP code predate 1980.

EPA PWSID
GA0510001
Population Served
28,423
Water Source
Surface Water
Max UCMR 5 PFAS
5.0 ppt (PFOA)
3-Yr Health Flags
0 Health Viol.
Water chemistry briefing — Pooler

Drawing surface water across Pooler, Pooler uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 5.0 ppt for PFOA (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 12,647 housing units in Pooler's 1 ZIP code (median value $284,300), 11.9% predates 1980 (3.9% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

How Clean and Hard Is Tap Water Supplied by Pooler?

Examine Pooler's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Chatham.

EPA SDWA and local housing profile for Pooler (GA0510001)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership GA0510001 (Local Government) Active CWS Last sanitary visit: 05/26/2026
Primary Source Water Surface Water Purchased GW vs. SW Disinfection byproduct check recommended
Service Area & Population 28,423 residents #54 in Georgia Counties: Chatham
Served ZIP Codes 31322 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 11.9% (3.9% pre-1960) 1986 Lead Ban Mostly post-1980 copper or PEX piping
3-Year EPA SDWA Compliance 1 rule violation (1 qtrs) Zero health flags target 8000=Revised Total Coliform Rule
State Tap Hardness Baseline 1.3 GPG (Soft) >= 7.0 GPG = Hard Moderate mineral profile

Are Forever Chemicals Detected in Pooler Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify GA0510001's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for GA0510001
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA 5.0 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFOS 4.6 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Who Are the Closest Georgia Community System Peers?

Compare four other Georgia utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Georgia for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
St. Simons Island (GA1270001) Saint Simons Island 29,249 Groundwater 0
Toccoa (GA2570001) Toccoa 28,711 Surface / Mixed 0
Chatsworth (GA2130000) Chatsworth 28,262 Surface / Mixed 0
Tifton-Tift County Water System (GA2770001) Tifton 27,589 Groundwater 0

When Should Pooler Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Pooler; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (1.3 GPG) and add scale inhibition on groundwater feeds.

Drinking Water & Pipe Safety FAQs: GA0510001

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Pooler's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Pooler (GA0510001) as a Surface Water Purchased community system serving 28,423 residents across Chatham. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

Should Pooler homeowners filter tap water for PFAS forever chemicals?

Yes—UCMR 5 laboratory testing for GA0510001 recorded 7 PFAS detections peaking at 5.0 ppt (PFOA), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

Does EPA's 10 ppb LCRI lead rule apply to houses on Pooler?

Across the 1 ZIP codes served by Pooler, approximately 11.9% of residential housing units were built before 1980 (3.9% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks