Valdosta Water Quality, PFAS & Utility Report (GA1850002)

Valdosta (GA1850002) is a Local Government public water utility serving 48,959 residents in Valdosta, Georgia primarily from ground water. EPA ECHO logs show zero EPA health violations alongside 2 monitoring/reporting notices, while UCMR 5 samples measured 7.0 ppt for PFOS (exceeding the 4.0 ppt federal rule). Roughly 12.9% of homes across 1 served ZIP code predate 1980.

EPA PWSID
GA1850002
Population Served
48,959
Water Source
Groundwater
Max UCMR 5 PFAS
7.0 ppt (PFOS)
3-Yr Health Flags
0 Health Viol.
Filtration & pipe verdict for Valdosta

Because Valdosta relies on groundwater wells, dissolved limestone and mineral salts commonly elevate scale formation inside tankless coils and electric water heater elements; Georgia's statewide USGS median is 1.3 GPG (Soft). UCMR 5 samples reached 7.0 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 9,642 housing units in Valdosta's 1 ZIP code (median value $211,900), 12.9% predates 1980 (1.7% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

What Are Valdosta's Source Water, Population, and Pipe Risk Metrics?

Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Valdosta's network.

EPA SDWA and local housing profile for Valdosta (GA1850002)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership GA1850002 (Local Government) Active CWS Last sanitary visit: 10/10/2023
Primary Source Water Ground Water GW vs. SW Harder mineral load expected
Service Area & Population 48,959 residents #34 in Georgia Counties: Lowndes
Served ZIP Codes 31605 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 12.9% (1.7% pre-1960) 1986 Lead Ban Mostly post-1980 copper or PEX piping
3-Year EPA SDWA Compliance 2 rule violations (10 qtrs) Zero health flags target 2456=Total Haloacetic Acids (Haa5), 2950=Tthm
State Tap Hardness Baseline 1.3 GPG (Soft) >= 7.0 GPG = Hard Moderate mineral profile

Did GA1850002 Detect PFAS Under EPA UCMR 5 Sampling?

Compare measured UCMR 5 laboratory results for Valdosta against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for GA1850002
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA 6.1 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFOS 7.0 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

How Does Valdosta Compare to Peer Georgia Utilities?

Review four nearby Georgia community water utilities matched by service rank inside Georgia's 252-utility public water catalog.

Nearby community water systems in Georgia for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Carroll County (GA0450001) Carroll 51,592 Surface / Mixed 0
Winder (GA0130002) Winder 51,540 Surface / Mixed 0
Newnan Utilities (GA0770002) Newnan 48,451 Surface / Mixed 0
Floyd County (GA1150001) Rome 46,143 Surface / Mixed 0

When Should Valdosta Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Valdosta; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (1.3 GPG) and add scale inhibition on groundwater feeds.

Homeowner Water Quality FAQs for Valdosta (GA1850002)

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Where does Valdosta (GA1850002) source drinking water?

EPA ECHO classifies Valdosta (GA1850002) as a Ground Water community system serving 48,959 residents across Lowndes. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

Were PFAS compounds detected in Valdosta UCMR 5 testing?

Yes—UCMR 5 laboratory testing for GA1850002 recorded 3 PFAS detections peaking at 7.0 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

Could homes served by Valdosta still face lead solder or older pipe risks?

Across the 1 ZIP codes served by Valdosta, approximately 12.9% of residential housing units were built before 1980 (1.7% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks