Skip to main content
EPA SDWA profile ยท IL0312040 (Illinois)

Norridge Water Quality, PFAS & Utility Report (IL0312040)

Ranked #163 of 454 major community water utilities in Illinois, Norridge (IL0312040) delivers surface water purchased to 15,251 people around Norridge. Public records indicate zero 3-year EPA health or monitoring rule violations on record and note that all 120 federal UCMR 5 PFAS lab runs tested non-detect. Recommended home check: Kitchen NSF 53 catalytic carbon filter.

EPA PWSID
IL0312040
Population Served
15,251
Water Source
Surface Water
Max UCMR 5 PFAS
0 ppt Detected
3-Yr Health Flags
0 Health Viol.
Homeowner takeaway for IL0312040

Drawing surface water across Norridge, Norridge uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.

Across 9,720 housing units in Norridge's 1 ZIP code (median value $347,600), 78.3% predates 1980 (41.5% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

Which Compliance and Housing Indicators Define IL0312040?

These verified utility measurements pair EPA SDWIS facility data for Norridge with Census housing vintage across its 1 served ZIP codes.

EPA SDWA and local housing profile for Norridge (IL0312040)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership IL0312040 (Local Government) Active CWS Last sanitary visit: 10/28/2024
Primary Source Water Surface Water Purchased GW vs. SW Disinfection byproduct check recommended
Service Area & Population 15,251 residents #163 in Illinois Counties: Cook
Served ZIP Codes 60706 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 78.3% (41.5% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 0 rule violations (0 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline Unmonitored in USGS extract >= 7.0 GPG = Hard Moderate mineral profile

How Do Norridge PFAS Levels Stack Up Against 4.0 ppt Rules?

EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Norridge's monitored results below.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for IL0312040
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

What Do Neighboring Community Water Systems Report in Illinois?

Cross-check four peer Illinois water utilities to see how Norridge ranks by system size, groundwater reliance, and EPA notices.

Nearby community water systems in Illinois for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Palos Heights (IL0312370) Palos Heights 15,500 Surface / Mixed 0
Wauconda (IL0971850) Wauconda 15,349 Surface / Mixed 0
Bethalto (IL1190150) Bethalto 15,210 Groundwater 0
Il American-Lincoln (IL1075030) Lincoln 15,200 Surface / Mixed 0

When Should Norridge Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Norridge; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

Key Questions About Tap Water From Norridge

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

What water source serves the 15,251 customers under EPA ID IL0312040?

EPA ECHO classifies Norridge (IL0312040) as a Surface Water Purchased community system serving 15,251 residents across Cook. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

How do Norridge PFAS levels compare to EPA's 4.0 ppt federal limit?

Federal UCMR 5 sampling covering 120 laboratory tests for Norridge reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

What pipe materials should homeowners served by Norridge inspect?

Across the 1 ZIP codes served by Norridge, approximately 78.3% of residential housing units were built before 1980 (41.5% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019โ€“2023 5-Year Summary File — U.S. Census Bureau, 2019โ€“2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks