Fleming Co Water Association Water Quality, PFAS & Utility Report (KY0350133)
Fleming Co Water Association (KY0350133) is a Private public water utility serving 9,693 residents in Fleming, Kentucky primarily from surface water purchased. EPA ECHO logs show zero EPA health violations alongside 1 monitoring/reporting notice, while all 360 federal UCMR 5 PFAS lab runs tested non-detect. Roughly 49.7% of homes across 7 served ZIP codes predate 1980.
- EPA PWSID
- KY0350133
- Population Served
- 9,693
- Water Source
- Surface Water
- Max UCMR 5 PFAS
- 0 ppt Detected
- 3-Yr Health Flags
- 0 Health Viol.
Drawing surface water across Fleming, Fleming Co Water Association uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. Surface water utilities disinfect with chlorine or chloramines; catalytic carbon cartridges remove taste, odor, and trihalomethane (TTHM) byproducts at the kitchen tap.
Across 18,024 housing units in Fleming Co Water Association's 7 ZIP codes (median value $113,986), 49.7% predates 1980 (27.5% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.
What Are Fleming Co Water Association's Source Water, Population, and Pipe Risk Metrics?
Audited below are the core EPA ECHO distribution metrics, served ZIP codes, and local housing-era indicators shaping plumbing longevity in Fleming Co Water Association's network.
| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | KY0350133 (Private) | Active CWS | Last sanitary visit: 09/27/2023 |
| Primary Source Water | Surface Water Purchased | GW vs. SW | Disinfection byproduct check recommended |
| Service Area & Population | 9,693 residents | #100 in Kentucky | Counties: Fleming |
| Served ZIP Codes | 41039, 41041, 41049, 41056, 41093, 41179, 41189 | 7 ZIP codes | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 49.7% (27.5% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 1 rule violation (2 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |
Did KY0350133 Detect PFAS Under EPA UCMR 5 Sampling?
Compare measured UCMR 5 laboratory results for Fleming Co Water Association against EPA's enforceable 4.0 ppt PFOA/PFOS limits and state Consumer Confidence reporting.
| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
How Does Fleming Co Water Association Compare to Peer Kentucky Utilities?
Review four nearby Kentucky community water utilities matched by service rank inside Kentucky's 221-utility public water catalog.
| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| Todd County Water District (KY1100944) | Todd | 9,801 | Surface / Mixed | 0 |
| North Mercer Water District (KY0840321) | Mercer | 9,775 | Surface / Mixed | 0 |
| Flatwoods Water Company (KY0450132) | Greenup | 9,649 | Surface / Mixed | 0 |
| Pikeville Water Department (KY0980350) | Pike | 9,638 | Surface / Mixed | 0 |
When Should Fleming Co Water Association Homeowners Upgrade Filtration or Test at the Tap?
Municipal utility compliance reports end at the street meter in Fleming; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.
Key Limitations & Exclusions
- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.
Which Option Fits Your Situation?
Homeowner Water Quality FAQs for Fleming Co Water Association (KY0350133)
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
Where does Fleming Co Water Association (KY0350133) source drinking water?
EPA ECHO classifies Fleming Co Water Association (KY0350133) as a Surface Water Purchased community system serving 9,693 residents across Fleming. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.
Were PFAS compounds detected in Fleming Co Water Association UCMR 5 testing?
Federal UCMR 5 sampling covering 360 laboratory tests for Fleming Co Water Association reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.
Could homes served by Fleming Co Water Association still face lead solder or older pipe risks?
Across the 7 ZIP codes served by Fleming Co Water Association, approximately 49.7% of residential housing units were built before 1980 (27.5% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.
Sources
- EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
- Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
- PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
- Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
- National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
- U.S. Census American Community Survey (ACS) 2019โ2023 5-Year Summary File — U.S. Census Bureau, 2019โ2023 5-Year Estimates (retrieved 2026-11-25)