Skip to main content
Community water audit · LA1073121 in LA

Gowc East Water System Water Quality, PFAS & Utility Report (LA1073121)

Homeowners connected to Gowc East Water System (LA1073121) in Ouachita Parish, Louisiana receive ground water across a 11,742-person distribution network. EPA SDWIS records document zero 3-year EPA health or monitoring rule violations on record; under UCMR 5 monitoring, all 120 federal UCMR 5 PFAS lab runs tested non-detect, and 44.8% of homes across 2 served ZIP codes predate 1980.

EPA PWSID
LA1073121
Population Served
11,742
Water Source
Groundwater
Max UCMR 5 PFAS
0 ppt Detected
3-Yr Health Flags
0 Health Viol.
Water chemistry briefing — Gowc East Water System

Drawing surface water across Ouachita Parish, Gowc East Water System uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. No UCMR 5 PFAS detections or active EPA health flags appear in this record; homes built before 1986 still benefit from an NSF 53 lead-rated faucet filter.

Across 17,178 housing units in Gowc East Water System's 2 ZIP codes (median value $181,200), 44.8% predates 1980 (9.9% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

How Clean and Hard Is Tap Water Supplied by Gowc East Water System?

Examine Gowc East Water System's raw source water category, historical SDWA violations, and pre-1980 neighborhood pipe exposure in Ouachita Parish.

EPA SDWA and local housing profile for Gowc East Water System (LA1073121)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership LA1073121 (Private) Active CWS Last sanitary visit: 03/20/2025
Primary Source Water Ground Water GW vs. SW Harder mineral load expected
Service Area & Population 11,742 residents #68 in Louisiana Counties: Ouachita Parish
Served ZIP Codes 71203, 71281 2 ZIP codes Verify utility on local municipal water bill
Pre-1980 Housing Share 44.8% (9.9% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 0 rule violations (0 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline Unmonitored in USGS extract >= 7.0 GPG = Hard Moderate mineral profile

Are Forever Chemicals Detected in Gowc East Water System Distribution Lines?

Federal UCMR 5 screening tracks synthetic PFAS compounds across US community utilities; verify LA1073121's maximum detections compound by compound.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for LA1073121
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFOS Non-detect (< MRL) 4.0 ppt EPA MCL Tested across federal UCMR 5 schedule
PFHxS Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Who Are the Closest Louisiana Community System Peers?

Compare four other Louisiana utilities of comparable population scale to benchmark source protection and treatment performance.

Nearby community water systems in Louisiana for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Buckeye Water District 50 (LA1079004) Rapides Parish 12,078 Groundwater 0
West Feliciana Consol Wwks District 13 (LA1125010) West Feliciana Parish 12,045 Groundwater 0
Houma Water Treatment Service Area (LA1109001) Terrebonne Parish 11,658 Surface / Mixed 0
City Of Carencro Water System (LA1055005) Lafayette Parish 11,301 Groundwater 2

When Should Gowc East Water System Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Ouachita Parish; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

Drinking Water & Pipe Safety FAQs: LA1073121

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

How does Gowc East Water System's supply type affect hardness and scale in home plumbing?

EPA ECHO classifies Gowc East Water System (LA1073121) as a Ground Water community system serving 11,742 residents across Ouachita Parish. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.

Should Gowc East Water System homeowners filter tap water for PFAS forever chemicals?

Federal UCMR 5 sampling covering 120 laboratory tests for Gowc East Water System reported zero quantifiable PFAS compounds above reporting limits, well under the 4.0 ppt federal PFOA/PFOS rule.

Does EPA's 10 ppb LCRI lead rule apply to houses on Gowc East Water System?

Across the 1 ZIP codes served by Gowc East Water System, approximately 44.8% of residential housing units were built before 1980 (9.9% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks