Skip to main content
Utility quality file · Frederick, MD (MD0100023)

Town Of Thurmont Water Quality, PFAS & Utility Report (MD0100023)

Supplying 6,200 customers across Frederick, Maryland, Town Of Thurmont (EPA ID MD0100023) relies on groundwater under influence of surface water for daily municipal flow. Current federal compliance files record zero 3-year EPA health or monitoring rule violations on record; meanwhile UCMR 5 samples measured 48.0 ppt for PFOS (exceeding the 4.0 ppt federal rule), and 51.9% of homes across 1 served ZIP code predate 1980.

EPA PWSID
MD0100023
Population Served
6,200
Water Source
Surface Water
Max UCMR 5 PFAS
48.0 ppt (PFOS)
3-Yr Health Flags
0 Health Viol.
Tap treatment summary — MD0100023

Drawing surface water across Frederick, Town Of Thurmont uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 48.0 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.

Across 5,102 housing units in Town Of Thurmont's 1 ZIP code (median value $342,700), 51.9% predates 1980 (30.8% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.

How Is Town Of Thurmont's Municipal Water Supplied and Regulated?

Review Town Of Thurmont's supply classification, customer headcount, local pre-1980 housing density, and 3-year Safe Drinking Water Act inspection metrics below.

EPA SDWA and local housing profile for Town Of Thurmont (MD0100023)
Water System ParameterMeasured / Reported ValueBenchmark / Federal LimitHomeowner Impact
EPA Utility ID & Ownership MD0100023 (Local Government) Active CWS Last sanitary visit: 08/26/2025
Primary Source Water Groundwater Under Influence Of Surface Water GW vs. SW Disinfection byproduct check recommended
Service Area & Population 6,200 residents #44 in Maryland Counties: Frederick
Served ZIP Codes 21788 1 ZIP code Verify utility on local municipal water bill
Pre-1980 Housing Share 51.9% (30.8% pre-1960) 1986 Lead Ban Higher likelihood of legacy lead solder or galvanized laterals
3-Year EPA SDWA Compliance 0 rule violations (0 qtrs) Zero health flags target No health-based compliance flags
State Tap Hardness Baseline Unmonitored in USGS extract >= 7.0 GPG = Hard Moderate mineral profile

What Do Federal PFAS Lab Results Show for Town Of Thurmont?

See how Town Of Thurmont (MD0100023) performed across federal UCMR 5 compounds alongside EPA's 4.0 ppt enforcement standard for PFOA and PFOS.

UCMR 5 laboratory monitoring and EPA PFAS 4.0 ppt rule check for MD0100023
Regulated Compound / ScreenMax DetectedEPA Regulatory StandardCompliance & Filtration Note
PFOA 15.0 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFOS 48.0 ppt 4.0 ppt EPA MCL Exceeds EPA threshold — NSF 58 RO strongly advised
PFHxS 5.3 ppt 10 ppt EPA MCL Detected below final EPA federal MCL
PFNA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule
HFPO-DA Non-detect (< MRL) 10 ppt EPA MCL Tested across federal UCMR 5 schedule

Which Nearby Maryland Water Utilities Match This Profile?

Compare population scale, water source, and compliance status across four comparable community systems operating in Maryland.

Nearby community water systems in Maryland for side-by-side comparison
Utility Name & PWSIDCity / CountyPopulation ServedPrimary SourceHealth Violations
Town Of Hampstead (MD0060003) Carroll 6,600 Groundwater 0
Bryans Road (MD0080033) Charles 6,260 Groundwater 0
Town Of Poolesville (MD0150002) Montgomery 6,005 Surface / Mixed 0
Mystic Harbour (MD0230011) Worcester 5,945 Groundwater 0

When Should Town Of Thurmont Homeowners Upgrade Filtration or Test at the Tap?

Municipal utility compliance reports end at the street meter in Frederick; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.

Key Limitations & Exclusions

  • Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
  • Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
  • Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.

Which Option Fits Your Situation?

Pre-1980 Home or Young Family Prioritize NSF/ANSI 53 or 58 drinking water filtration tested for both lead and PFAS.
Installing a New Tankless Water Heater Check tap hardness (7+ GPG) and add scale inhibition on groundwater feeds.

Practical Drinking Water Questions for Frederick Residents

Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.

Does Town Of Thurmont draw from groundwater aquifers or surface water reservoirs?

EPA ECHO classifies Town Of Thurmont (MD0100023) as a Groundwater Under Influence Of Surface Water community system serving 6,200 residents across Frederick. Surface supplies pull from rivers, lakes, or reservoirs and require chlorine or chloramine disinfection plus monitoring for disinfection byproducts.

What did federal UCMR 5 sampling measure in MD0100023?

Yes—UCMR 5 laboratory testing for MD0100023 recorded 31 PFAS detections peaking at 48.0 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.

How does local home age affect plumbing risk inside MD0100023's service area?

Across the 1 ZIP codes served by Town Of Thurmont, approximately 51.9% of residential housing units were built before 1980 (30.8% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.

Sources

  1. EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
  2. Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
  3. PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
  4. Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
  5. National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
  6. U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)

Related U.S. Metro Plumbing Benchmarks