Seekonk Water District Water Quality, PFAS & Utility Report (MA4265000)
Ranked #150 of 262 major community water utilities in Massachusetts, Seekonk Water District (MA4265000) delivers ground water to 13,801 people around Seekonk. Public records indicate zero 3-year EPA health or monitoring rule violations on record and note that UCMR 5 samples measured 5.0 ppt for PFOS (exceeding the 4.0 ppt federal rule). Recommended home check: Install NSF 58 under-sink RO or NSF 53 PFAS carbon.
- EPA PWSID
- MA4265000
- Population Served
- 13,801
- Water Source
- Groundwater
- Max UCMR 5 PFAS
- 5.0 ppt (PFOS)
- 3-Yr Health Flags
- 0 Health Viol.
Drawing surface water across Seekonk, Seekonk Water District uses chlorination or chloramines for biological safety, which can leave chlorine taste or trace trihalomethanes best addressed with NSF/ANSI 53 catalytic carbon. UCMR 5 samples reached 5.0 ppt for PFOS (at or above EPA's 4.0 ppt enforceable MCL). Prioritize an under-sink NSF/ANSI 58 RO membrane or NSF 53 PFAS-certified block filter for drinking and cooking water.
Across 6,324 housing units in Seekonk Water District's 1 ZIP code (median value $461,600), 68.5% predates 1980 (38.1% pre-1960), meaning private copper solder or galvanized risers often warrant flushing or NSF 53 lead polishing even when distribution mains pass EPA's 10 ppb LCRI benchmark.
Which Compliance and Housing Indicators Define MA4265000?
These verified utility measurements pair EPA SDWIS facility data for Seekonk Water District with Census housing vintage across its 1 served ZIP codes.
| Water System Parameter | Measured / Reported Value | Benchmark / Federal Limit | Homeowner Impact |
|---|---|---|---|
| EPA Utility ID & Ownership | MA4265000 (Local Government) | Active CWS | Last sanitary visit: 07/23/2025 |
| Primary Source Water | Ground Water | GW vs. SW | Harder mineral load expected |
| Service Area & Population | 13,801 residents | #150 in Massachusetts | Counties: Bristol |
| Served ZIP Codes | 02771 | 1 ZIP code | Verify utility on local municipal water bill |
| Pre-1980 Housing Share | 68.5% (38.1% pre-1960) | 1986 Lead Ban | Higher likelihood of legacy lead solder or galvanized laterals |
| 3-Year EPA SDWA Compliance | 0 rule violations (0 qtrs) | Zero health flags target | No health-based compliance flags |
| State Tap Hardness Baseline | Unmonitored in USGS extract | >= 7.0 GPG = Hard | Moderate mineral profile |
How Do Seekonk Water District PFAS Levels Stack Up Against 4.0 ppt Rules?
EPA's National Primary Drinking Water Regulation sets strict 4.0 ppt limits on PFOA and PFOS; inspect Seekonk Water District's monitored results below.
| Regulated Compound / Screen | Max Detected | EPA Regulatory Standard | Compliance & Filtration Note |
|---|---|---|---|
| PFOA | Non-detect (< MRL) | 4.0 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFOS | 5.0 ppt | 4.0 ppt EPA MCL | Exceeds EPA threshold — NSF 58 RO strongly advised |
| PFHxS | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| PFNA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
| HFPO-DA | Non-detect (< MRL) | 10 ppt EPA MCL | Tested across federal UCMR 5 schedule |
What Do Neighboring Community Water Systems Report in Massachusetts?
Cross-check four peer Massachusetts water utilities to see how Seekonk Water District ranks by system size, groundwater reliance, and EPA notices.
| Utility Name & PWSID | City / County | Population Served | Primary Source | Health Violations |
|---|---|---|---|---|
| Medway Water Department (MA2177000) | Medway | 14,176 | Groundwater | 0 |
| Wayland Water Department (MA3315000) | Wayland | 14,096 | Groundwater | 0 |
| Northborough Water Department (Mwra) (MA2215000) | Northborough | 13,551 | Surface / Mixed | 0 |
| Ipswich Dpu Water Dept (MA3144000) | Ipswich | 13,138 | Surface / Mixed | 0 |
When Should Seekonk Water District Homeowners Upgrade Filtration or Test at the Tap?
Municipal utility compliance reports end at the street meter in Seekonk; interior pipe vintage and specific UCMR 5 detections determine point-of-use protection.
Key Limitations & Exclusions
- Municipal compliance does not cover private galvanized steel or pre-1986 lead-solder branch lines inside older homes.
- Reverse osmosis (NSF 58) discards concentrate brine down the drain; confirm kitchen under-sink shutoffs and drain saddle fit.
- Verify the utility's latest annual Consumer Confidence Report (CCR) before sizing high-capacity whole-house carbon or softening tanks.
Which Option Fits Your Situation?
Key Questions About Tap Water From Seekonk Water District
Direct answers to common technical, regulatory, and sizing questions sourced from primary U.S. government and OEM documentation.
What water source serves the 13,801 customers under EPA ID MA4265000?
EPA ECHO classifies Seekonk Water District (MA4265000) as a Ground Water community system serving 13,801 residents across Bristol. Groundwater supplies draw from subsurface aquifers and typically carry higher dissolved calcium and magnesium carbonate, making annual tank flushing and scale protection important.
How do Seekonk Water District PFAS levels compare to EPA's 4.0 ppt federal limit?
Yes—UCMR 5 laboratory testing for MA4265000 recorded 2 PFAS detections peaking at 5.0 ppt (PFOS), which sits at or above EPA's 4.0 ppt enforceable MCL. NSF/ANSI 58 reverse osmosis or NSF 53 PFAS-rated carbon effectively reduces exposure at the drinking tap.
What pipe materials should homeowners served by Seekonk Water District inspect?
Across the 1 ZIP codes served by Seekonk Water District, approximately 68.5% of residential housing units were built before 1980 (38.1% pre-1960). Older service lines and pre-1986 50/50 tin-lead copper solder can leach lead indoors even when utility mains test compliant under EPA's 10 ppb LCRI threshold.
Sources
- EPA ECHO Safe Drinking Water Act (SDWA) Public Water Systems Download — U.S. Environmental Protection Agency, SDWA System Search Extract (retrieved 2026-11-23)
- Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) Occurrence Data by State — U.S. Environmental Protection Agency, UCMR 5 State Occurrence Release (retrieved 2026-11-23)
- PFAS National Primary Drinking Water Regulation & LCRI Overview — U.S. Environmental Protection Agency, 40 CFR Part 141 / 2026 Status (retrieved 2026-11-23)
- Lead and Copper Rule Improvements (LCRI) & Service Line Inventories — U.S. Environmental Protection Agency, 40 CFR Part 141 Subpart I (retrieved 2026-11-23)
- National Water Quality Monitoring Council Water Quality Portal (Hardness, Ca, Mg) — USGS & U.S. EPA, WQP Result Service (retrieved 2026-11-23)
- U.S. Census American Community Survey (ACS) 2019–2023 5-Year Summary File — U.S. Census Bureau, 2019–2023 5-Year Estimates (retrieved 2026-11-25)